4. Commissioning
MF0150A9A
_prel.docx
Manual for ION-M23 SDARS 3-Sector
Page 29
5. Retain the cable connector with the
counter wrench and fasten the
coupling nut with the torque wrench
until the torque is applied (torque
wrench clicks).
For angled antenna connectors use
your hand to retain the cable connector
and fasten the coupling nut with the
torque wrench. Make sure only the
coupling nut is turned, not the cable
connector.
4.2.8. Optical-Fiber-Cable Connection - Rules
Main optical system parameters:
Fiber:
Single mode fiber, type is E9/125 µm
Attenuation: <0.36 dB / km @ 1310 nm
/
<0.26 dB / km @ 1550 nm
Dispersion: <3.5 ps / nm km @ 1310 nm /
<18.0 ps / nm km @ 1550 nm
Fibre-cable connectors E2000 APC 8°
ION-M system:
The pigtails for the connection between Master Unit and Remote Unit must have
a sufficient length. Protection for the optical fibers must be provided where the
fibers feed into the units.
The system attenuation of the optical fibers, including the connectors, must
not
exceed 10 dB.
System attenuation and attenuation of optical components must be determined. This
can be achieved by measuring attenuation with an appropriate measuring instrument.
For pigtails, a total value of <0.4 dB (measured to a reference plug) can be assumed
due to the dead zone of the reflectometer. These measurements must be made with a
sufficient length of optical fiber, at the input and output of the device which has to be
measured.
Fiber-System Installation:
Fiber-cable connectors have to be of the same type (E2000 APC 8°) as the connectors
used for the unit. The fiber-optic cables are connected to the optical transceiver.
Note:
Angled connectors are not compatible with straight optical
connectors; non-compatibility of connectors will result in
permanent damage to both connectors.
Torque wrench
Counter
wrench