4. Commissioning
Page 22
MF0150A9A
_prel.docx
Manual for ION-M23 SDARS 3-Sector
4.2. Electrical Installation
4.2.1. Health and Safety for Electrical Installation
Read and observe chapter
1.2 Health and Safety
.
Danger: Electrical hazard. Danger of death or fatal injury from electrical
current. Obey all general and regional installation and safety regulations
relating to work on high voltage installations, as well as regulations
covering correct use of tools and personal protective equipment.
4.2.2. Property Damage Warnings for Electrical Installation
1.
Attention:
It is compulsory to ground (earth) the unit before connecting the power
supply. Grounding bolts are provided on the cabinet to connect the ground-bonding
cable.
2.
Attention:
If the mains connector of the Remote Unit is not easily accessible, a
disconnect device in the mains power circuit must be provided within easy reach.
3.
Attention:
A connection of the mains supply to a power socket requires the power
socket to be nearby the Remote Unit.
4.
Attention:
Before connecting or disconnecting the mains connector at the Remote
Unit, ensure that mains power supply is disconnected.
5.
Attention:
Make sure that an appropriate circuit breaker acting as a disconnect
device (as required by IEC/EN60950-1) and an overcurrent limiting device are
connected between mains power and the Remote Unit.
6.
Attention:
Incorrectly wired
connections
can destroy electrical and electronic
components.
7.
Notice:
To avoid corrosion at the connectors caused by electrochemical
processes, the material of the cable connectors must not cause a higher potential
difference than 0.6 V (see electrochemical contact series).
8.
Notice:
Use an appropriate torque wrench for the coupling torques:
-
for 4.3-10 type connectors (5 N-m, 44 in lb) with 22mm (7/8) in opening,
e.g. item no. TW-4310
Do NOT use your hands or any other tool (e.g. a pair of pliers). This might cause
damage to the connector and lead to a malfunction of the Remote Unit.
9.
Notice
:
For unstabilized electric networks, which frequently generate spikes, the
10.
Notice:
Observe the labels on the front panels before connecting or disconnecting
any cables.
11.
Notice:
Unused connectors must be closed with their protective covers to ensure
watertightness.