![CommScope FOSC-400A4 Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/commscope/fosc-400a4/fosc-400a4_installation-instruction_2643747014.webp)
14
9.4
Place the dome carefully over the trays
onto the base. Put the clamp around the
base/dome interface. Close the clamp.
10.2
Remove carefully the dome avoiding
damaging the sealing ring and fiber
management.
10.3
Remove gently the sealing ring. Keep
the sealing ring and seal area of the closure
free of dirt (if needed rinse with clear water).
10.4
The dome may be reinstalled by
following the procedure as described in
section 9. Replace the 75 grams of desiccant.
The sealing ring has also to be replaced if
damaged.
A new sealing ring and 75 gram
of desiccant can be ordered: FOSC-A/B-O-
RING-SEAL-KIT.
10.1
Remove the clamp.
10
Re-entry