![CommScope FOSC-400A4 Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/commscope/fosc-400a4/fosc-400a4_installation-instruction_2643747011.webp)
11
7.1.6 For 8 fiber capacity tray, two fusion
protection sleeves should be installed on top
of one another in one splice holder.
7.2.1 The tray organizer has 4 positions to
store splice protectors. Each position can hold
maximum 4 fusion splice protectors of type
SMOUV-1120-02 (length = 45 mm, installed
outer diameter is 2,4 mm) or
equivalent.
Make sure the cable has been
stripped to a maximum length
of 1.1 m.
7.2.2 After each splice is made, the splice
should be stored as indicated on the drawing
(see 7.2.1.). First protector in position 1,
the second in position 2. Continue for other
fibers. Fiber n°5 will be in position 1 of next
location. Coil the excess length of fiber each
time you have positioned the splice protector.
7.1.7 Upon completion of splicing, install the
clear protective cover on the tray.
7.2
If a FOSC-A-TRAY-S16-1 is used.
Tray for up to 16 short fusion splice
protectors