ODPMT200 Series DryLine® Dehydrator User Manual
5
Figure 2 - Changing Alarm Outputs:
Output Pressure Constant
5.0 psig
Output capacity
12.0 SCFH (80Iiters/h)
(total, approx.) 0.2
SCFH (1.5 liters/m)
Output Dew Point,
-49°F (-45°C) or better
Operating Temperature
-30° to +130° F
Range
(-34° to +54° C)
Low Pressure Alarm
1.0 lb/in2 (6.9 kPa)
Electrical Input
115 Vac, 50/60 Hz
Output Connector
3/8” polytube,
compression
Dimensions
18.5” W x 32.0” H x
10.0” D
Optional Alarms:
High Humidity Alarm
Set Point
7.5% RH, factory set
Excess Run Alarm
Set Point
10 minutes, factory set
Power Fail Alarm
loss of input power
Alarm
Factory setting
Where To
Reset
Low
Normally
Alarm switch
Pressure
Closed (N.C.)
center term.
N.O., bottom
term N.C.
Mains
Normally
Power Fail
(Power)
Open (N.O.)
Jumper JP6 on
Alarm PCB
Excess
Normally
Jumper JP5 on
Run
Open (N.O.)
Run Alarm
PCB
High
Normally
Jumper JP4 on
Humidity
Open (N.O.)
Alarm PCB