background image

6

GENERAL SAFETY INSTRUCTIONS (cont.)

e) Maintain power tools. 

Check for misalignment or binding of moving parts, breakage of parts and

any other condition that may affect the power tools operation. If damaged, have the power tool

repaired before use. Many accidents are caused by poorly maintained power tools.

f) Keep cutting tools sharp and clean. 

Properly maintained cutting tools with sharp cutting edges

are less likely to bind and are easier to control.

g) Use the power tool, accessories and tool bits etc., in accordance with these instructions and

in the manner intended for the particular type of power tool, taking into account the working

conditions and the work to be performed. 

Use of the power tool for operations different from

intended could result in a hazardous situation.

5) SERVICE
a) Have your power tool serviced by a qualified repair person using only identical

replacement parts. 

This will ensure that the safety of the power tool is maintained.

ADDITIONAL SAFETY INSTRUCTIONS FOR PUMPS

CAUTION: 

Not intended for cleaning and other maintenance of swimming pools.

CAUTION: 

Commercial Electric recommends the power outlet to be used for the water pump, be

protected by a 30mA residual current device or earth leakage circuit breaker.

WARNING! 

This product is intended for pumping water in a home domestic application. Do

not use it for corrosive, abrasive, explosive or dangerous liquids. Fluids other than water

will damage the water pump and/or create a fire hazard.

This appliance is not intended for use by person (including children) with reduced physical,

sensory or mental capabilities, or lack of experience and knowledge, unless they have been

given supervision or instruction concerning use of the appliance by a person responsible for

their safety.
Children should be supervised to ensure that they do not play with the appliance.

•  Ensure the water pump is disconnected from mains power when installing.
•  Do not install or operate the water pump in an explosive environment or near flammable material.
•  Do not operate the water pump without liquid.
•  Do not run the water pump dry.

WARNING! 

The water pump together with associated pipework operate under pressure. Do

not disconnect water pump or pipework until internal pressure has been released. Failure to

do this could result in personal injury and damage to property.

•  Avoid inserting hands into the inlets/outlets of the water pump while it is connected to mains power.
•  Before using the water pump, always inspect it visually. Do not use the pump if it is cracked

and/or damaged. If the water pump is damaged, contact Commercial Electric customer service.

•  The water pump has a built-in thermal protection overload switch. The water pump stops if an

overload occurs. The motor restarts automatically after it has cooled down.

Never work or perform maintenance on the pump without first making sure it has been disconnected

from the mains power.
Pollution of the liquid could occur due to leakage of lubricants.

IMPORTANT:

Avoid inserting hands into the mouth of the pump if it is connected to the mains.

The electrical connection must always be made in a dry area. Make sure that electrical connections

are protected from inundations.
Protect the plug and the power cable from heat, oil or sharp edges.
If damaged, The power cable must be replaced by a qualified electrician.

!!

!!

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

    

Содержание PPT-800

Страница 1: ...00 INSTRUCTION MANUAL 0112 WARNING Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious injury Save all warnin...

Страница 2: ...or garden watering and washing cars transferring water from tanks ponds and dams and transferring water for domestic irrigation This product is not suitable for use with drinking potable water SPECIFI...

Страница 3: ...r Cover 3 Suction Inlet 4 Pump Housing 5 Drain Screw 6 Pressure Tank 7 Pressure Gauge 8 On Off Switch 9 Handles 10 Filter 11 Power Cable not shown 12 Air Valve Cover not shown 13 Air Valve not shown 1...

Страница 4: ...TRUCTIONS ADDITIONAL SAFETY INSTRUCTIONS FOR PUMPS SUGGESTED APPLICATIONS PACK CONTENTS FITTINGS AND TOOLS REQUIRED FOR INSTALLATION SET UP INSTALLATION OPERATION HINTS WHEN USING THE PUMP MAINTENANCE...

Страница 5: ...hermal protection overload switch The water pump stops if an overload occurs The motor restarts automatically after it has cooled down Using an extension lead Always use an approved extension lead sui...

Страница 6: ...e safety equipment Always wear eye protection Safety equipment such as dust mask nonskid safety shoes hard hat or hearing protection used for appropriate conditions will reduce personal injuries c Avo...

Страница 7: ...al sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Ch...

Страница 8: ...watering and washing cars and boats Transferring water for domestic irrigation CAUTION Not to be used to circulate swimming pool water PACK CONTENTS 1 x Automatic pressure pump PPT 800 1 x Pre filter...

Страница 9: ...nected when using the pump Connecting Hose or Pipe to the Suction Inlet 1 Remove the plastic protection cover from the suction inlet 3 Fig 2 Note It is recommended that you use a suction set with suct...

Страница 10: ...ose or pipe and impede the priming process see section starting the pump for description on priming the pump Fig 5 7 150mm WATER TANK GATE VALVE NON RETURN VALVE UNION COUPLING SUCTION LINE FIRM BASE...

Страница 11: ...s the pump will not run dry Ensure that this is checked when in operation Note A leaking hose or pipe will draw in air and therefore not draw in any water WATER TANK NON RETURN VALVE SUCTION LINE UNIO...

Страница 12: ...mum diameter of 19mm 3 4 A smaller diameter output hose or pipe will result in a lower flow rate Note Ensure the output hose or pipe is not restricted in any way and no pressure is obstructing the hos...

Страница 13: ...vity completely fill the pump housing 4 with water Fig 13 5 Replace the filter 10 into the filter cavity 6 Tighten the transparent filter cover 2 securely by turning clockwise Note Do not operate the...

Страница 14: ...only operate when water is drawn at the discharge outlet 1 At all other times the pump will cease operation to conserve energy When water is used and the pump s pressure decreases to 1 5 bar the pump...

Страница 15: ...least 150mm from a solid structure i e wall or fence Running the pump with no water flowing through the pipes will reduce the life of the pump and is not recommended The pump must be turned off at th...

Страница 16: ...als are not covered under warranty Cleaning the Pump Housing Use a moist cloth to wipe down the pump housing 4 Allow to dry thoroughly before storing in a dry location that is protected from bad weath...

Страница 17: ...let and filter for any foreign matter Pump is not producing enough pressure Check all parts of the pump and clean and check the tank pressure Water source does not have enough water Wait until the wat...

Страница 18: ...owing the motor to cool Ensure the pump is in a well ventilated area The motor is faulty or damaged Contact Commercial Electric customer service Poor Performance low pressure flow Faulty suction line...

Страница 19: ...ally friendly way Please recycle where facilities exist Check with your local council authority for recycling advice Recycling packaging reduces the need for landfill and raw materials Reuse of recycl...

Страница 20: ...T RETURN THE PRODUCT TO YOUR NEAREST BUNNINGS WAREHOUSE WITH YOUR BUNNINGS REGISTER RECEIPT PRIOR TO RETURNING YOUR PRODUCT FOR WARRANTY PLEASE TELEPHONE OUR CUSTOMER SERVICE HELPLINE TO ENSURE A SPEE...

Отзывы: