background image

 6

Installation (continued)

Removing the mounting plate

NOTE:

 The mounting plate (D) and mounting plate bolt (C) 

come pre-assembled on the light fixture (A) for shipping.

 

Remove the mounting plate (D) from the back 
of the fixture by loosening the mounting plate 
bolt (C) using the Allen key (DD).

NOTE:

 Only unscrew the bolt (C) far enough to remove the 

mounting plate (D). Do not fully remove the bolt (C).

D

C

DD

Installing the mounting plate

 

Route the junction box wires through the large 
center hole in the mounting plate (D).

 

Align the holes on the mounting plate (D) 
with the holes on your junction box. Use two 
#8 screws (AA), depending on the size of 
the holes in your junction box, to attach the 
mounting plate (D) to your junction box

 

Please make sure

 the “TOP” is upwards.

AA

D

Hanging the fixture to the 

mounting plate

 

Place the small sphere head of the hanger 
wire (E) between the back of the small groove 
located on the bottom of the center hole of the 
mounting plate (D).

 

Ensure the photocell (B) is facing upwards 
when the light fixture (A) is installed.

NOTE:

 Ensure the light fixture (A) can safely hang onto the 

mounting plate (D) to allow for use of two hands to make the 
wiring connections.

D

E

A

A

B

D

E

B

Содержание PHX12-3K-BZ

Страница 1: ...your home Visit us online to see our full line of products available for your home improvement needs Thank you for choosing Commercial Electric USE AND CARE GUIDE PHOENIX LED ARCHITECTURAL WALLPACK Q...

Страница 2: ...device must accept any interference received including any interference that may cause undesired operation This equipment has been tested and found to comply with the limits for a Class A digital devi...

Страница 3: ...description of the problem Pre Installation PLANNING INSTALLATION Before installing the light fixture ensure that all parts are present Compare parts with the Hardware Included and Package Contents s...

Страница 4: ...ew 2 BB Wire nut 3 CC Clear photocell light sensor screw on cap 1 DD Allen key 1 PACKAGE CONTENTS B F E D A C Part Description Quantity A Light fixture 1 B Photocell light sensor 1 C Mounting plate bo...

Страница 5: ...ductive load Do NOT wire to dimming switch When mounting the fixture make sure the photocell orientation is at the top for wall mount When mounting to a wall make sure the fixture is 7 in on center aw...

Страница 6: ...mounting plate D Align the holes on the mounting plate D with the holes on your junction box Use two 8 screws AA depending on the size of the holes in your junction box to attach the mounting plate D...

Страница 7: ...r tightness by pulling wires Line Black White Lighting Fixture Green Common Ground 3 8 in A D BB 6 Mounting the light fixture Place the light fixture A onto the mounting plate D so the top sloped groo...

Страница 8: ...ns OFF NOTE If photocell B is located in an area under heavy shade the photocell may not detect enough light and may turn the light fixture on CC F A B Option 2 Switch controlled Switch controlled ope...

Страница 9: ...ers The light fixture is wired through a dimmer switch Do not use a dimmer switch to control the light fixture Replace the dimmer with a standard ON OFF switch The light stays ON The light sensor is i...

Страница 10: ...Questions problems missing parts Before returning to the store call Commercial Electric Customer Service 9 a m 5 p m EST Monday Friday 1 844 548 3776 HOMEDEPOT COM Retain this manual for future use...

Отзывы: