background image

 

HOMEDEPOT.COM 

 

 

Please contact 1-877-527-0313 for further assistance. 

Maintenance (continued) 

 

 

□ 

Turn the meter off by turning the switch to the OFF position. 

□ 

Disconnect the test leads and any connectors from the terminals on the meter. 

□ 

Use a screwdriver to unscrew and remove the battery cover located on the back of the meter. If you are replacing the fuse, unscrew all 
of the screws on the back of the meter. 

□ 

Remove the used batteries or damaged fuse. 

□ 

Replace with a new battery or fuse. 

□ 

Reattach the battery cover and secure with the screws. 

TEST LEAD REPLACEMENT 

Replacement test leads must meet the manufacturer’s specifications (EN 610 10-031 standard, CAT III 600V 10A, or better). 

 

Care and Cleaning 

 

 

□ 

Periodically wipe the meter with a damp cloth and mild detergent.  

□ 

Do not use abrasives or solvents. 

□ 

Dirt or moisture in the terminals can affect readings. 
 

To clean the terminals: 

□ 

Turn the meter off and remove all test leads. 

□ 

Shake out any dirt that may be in the terminals. 

□ 

Soak a new cotton swab with a cleaning and oiling agent (such as WD-40). 

□ 

Work the swab around in each terminal. The oiling agent insulates the terminals from moisture-related contamination. 

Содержание MS8132A

Страница 1: ...ee our full line of products available for your home improvement needs Thank you for choosing Commercial Electric Item 826 403 Model MS8132A USE AND CARE GUIDE DIGITAL MULTIMETER Questions problems mi...

Страница 2: ...nd pollution degree 2 The meter can be used for measuring DC voltage AC voltage resistance diode and batteries Use the meter strictly according to the provisions of this manual Otherwise the warranty...

Страница 3: ...esistance continuity diodes or capacitance WARNING Before measuring current check the meter s fuse and turn off power to the circuit before connecting the meter to the circuit WARNING Do not measure v...

Страница 4: ...switch Rotate to select a measurement mode C Common input jack Connect to the black test lead D Positive input jack Connect to the red test lead to measure DC voltage AC voltage resistance diode and...

Страница 5: ...lue polarity indicator negative sign 3 Battery low voltage indicator 4 Measurement display value ACCURACY Function Range Accuracy ACV 1V 300V 2 0 of reading 10 digits DCV 1V 300V 2 0 of reading 8 digi...

Страница 6: ...voltage measurement CAUTION To avoid electrical shock and or damage to the meter do not attempt to take any voltage measurement that might exceed 300V DC or AC rms CAUTION Do not measure AC DC voltage...

Страница 7: ...3 Completing a diode measurement WARNING To avoid damage to the meter or equipment being measured cut off all power supply to the measured circuits and discharge all high voltage capacitors before me...

Страница 8: ...maintenance or repair work carried out on the meter while it is live should be carried out by a qualified electrician WARNING When you open the meter remember that some internal capacitors can retain...

Страница 9: ...r fuse Reattach the battery cover and secure with the screws TEST LEAD REPLACEMENT Replacement test leads must meet the manufacturer s specifications EN 610 10 031 standard CAT III 600V 10A or better...

Страница 10: ...roblems missing parts Before returning to the store call Commercial Electric Customer Service 8 a m 7 p m EST Monday Friday 9 a m 6 p m EST Saturday 1 877 527 0313 HOMEDEPOT COM Retain this manual for...

Отзывы: