Security and Communication
Please follow the following instruction for the installation of the Induction Loop Amplifier module:
– Open the WS station - instruction see respective short reference
– Disconnect the station from the Intercom network and if used, from the external power supply.
– Mount the Induction Loop on the surface or flush mount box as shown in the following picture
– Snap the Induction Loop Amplifier module in the slot of the WS station:
– It is only possible to snap the module in the middle slot of the WS station!
– If in the middle slot a Camera module or a TFT-Display module is used, it is not possible to mount the induction loop amplifier module.
Quick Start
Note:
It is mandatory to install the induction loop on the right side of
the housing, as shown in the connection diagram. Otherwise
disturbing hum may occur. For the installation use the attached
mounting clips and screws (in extent of supply).
Induction loop
Mounting clip
Surface or Flush Mount Kit