MANUAL VERSION 2.0/0817

PRODUCT MANUAL

ENGLISH

Содержание C-G3-TEL

Страница 1: ...G8 TEL G3 TEL MANUAL VERSION 2 0 0817 PRODUCT MANUAL ENGLISH...

Страница 2: ...event of problems contact your equipment supplier in the first instance Before exchanging cards ESD precautions must be observed Installation reference for Germany The G3 TEL G8 TEL card may be connec...

Страница 3: ...from the telephone to the Intercom system 13 Configure auto dialler mode 13 Speech storage 17 Pre recorded audio for speech storage 20 Recording messages at the Intercom station 20 PABX mode 22 Outgoi...

Страница 4: ...n By dialling the telephone interface it is possible to dial into the Intercom Server from any telephone within the telephone network By doing this Intercom functions can be carried out with the DTMF...

Страница 5: ...connection RJ11 Power supply via Intercom Server Emergency power consumption 0 1 Ah h Operating temperature range 0 C to 50 C 32 F to 122 F Storage temperature range 30 C to 60 C 22 F to 140 F Relativ...

Страница 6: ...nnection to the main processor e g during initialising or reset LED flashes fast card is inserted in the wrong slot or speech messages are loaded Status telephone line LINE LED is permanently on on ho...

Страница 7: ...m Server GE 800 the connection board G8A TEL has to be used included in extent of supply Pin assignment connection board G8A TEL G3 TEL The G3 TEL is designed for the Intercom Server GE 300 The card c...

Страница 8: ...through after a configurable time Display the dialled telephone number The telephone number dialled in PABX mode is shown on the display In addition a cursor shows if the dialling process has been co...

Страница 9: ...all number several times in a dialling sequence Example Call numbers 1 Guard 1 2 Guard 2 3 SIP mobile phone 1 4 SIP mobile phone 2 In the daytime Dialling sequence 1 is selected by a time switch When...

Страница 10: ...u will be immediately connected to an emergency station This message is repeated until the call is taken over via the telephone Messages at the telephone Location message The telephone receives the lo...

Страница 11: ...rsation can be set up or other functions can be carried out in the Intercom Server If the telephone is only hanged up without pressing the connection is automatically disconnect ed after approx 6 seco...

Страница 12: ...on Telephone within the public telephone net Initiate a call Calm down message Telephone is ringing Going off hook Location message Enter password Individual message optional Call Conversation End Can...

Страница 13: ...ing the conversation at the telephone Repeated speech messages can be interrupted with see also Individual messages on page 19 However each message has to be listened to at least once Cancel conversat...

Страница 14: ...alled max 8 digits e g an exchange number for dialling out or for selecting a certain provider Admissible characters 0 to 9 or P for one second pause In the field DTMF decoding time ms enter if requir...

Страница 15: ...ve code Input initiates dialling window in CCT 800 In the example above screenshot one input triggers the switch over of the dialling sequences 1 and 2 for the subscriber 1 telephone interface Level i...

Страница 16: ...e will be transferred via the telephone interface as Active 2 Standard The call type will be grouped to none of the above listed call types Initiate call Call via dialling interface At the Intercom st...

Страница 17: ...0 Ruf Call Appel 11 Rufe Calls Appels 12 Notruf Emergency call Appel de secours 13 Notrufe Emergency calls Appels de secours 14 Bitte bewahren Sie Ruhe Sie werden sofort zu einem Not rufservice durchg...

Страница 18: ...al data on page 5 For an overview of switching on several speech messages in auto dialler mode see Switch on speech messages on page 10 and Examples for the call procedure on page 12 NOTES Calm down m...

Страница 19: ...f the Intercom station to or from which the call is initiated If the message shall be valid for all Intercom stations enter In the drop down list Call Type select the event or the type of the respecti...

Страница 20: ...tion Speech storage messages see Standard speech messages on page 17 can also be recorded at the Intercom station The recording can be performed in normal operation in order to test the speech stor ag...

Страница 21: ...essage and release T when the message is complete Press 0 to listen to the recording Press 1 to save the recorded message Further options Press X to cancel without saving Press 2 to load a recorded me...

Страница 22: ...t is possible to define several phone numbers per telephone interface via the PA function see Phone call by direct outward dialling on page 26 which can be dialled directly at the Intercom sta tion wi...

Страница 23: ...ll from the telephone to the Intercom system Initiate call A call in PABX is initiated in the same way as in auto dialler mode see page 13 Cancel conversation A conversation in PABX mode is cancelled...

Страница 24: ...f the sequence hast to be dialled if the call was not accepted In the drop down list Dial tone telephone select the dial tone for the telephone or deactivate it Options None British 440Hz and Telephon...

Страница 25: ...an ap propriate configuration in CCT 800 is required see Calm down message for call requests on page 18 Phone call by dialling manually To set up a phone call by dialling the telephone interface manua...

Страница 26: ...f all required numbers are entered click on Accept The entered numbers are indicated in the field PA Numbers PA numbers in CCT 800 After dialling at the telephone outgoing phone call For outgoing phon...

Страница 27: ...ring the last digit of the respective telephone number the after dial mode is switched automatically from DTMF dialling to Intercom dialling I e it is possible to after dial into the Intercom system V...

Страница 28: ...istening to a channel and talking into a channel at the telephone 7T predefined conference Initiating a 7T conference at the telephone 8T conference On the telephone a conference can be initiated in t...

Страница 29: ...g function at the telephone at PABX mode an appropriate configuration in CCT 800 is required see After dialling at the telephone outgoing phone call on page 26 ATTENTION Button 7 When using the teleph...

Страница 30: ...Technical support G8 TEL G3 TEL 30 2 0 0817 Technical support For more information about our products and services visit www commend com...