11
button simultaneously for 5 seconds, you can turn the sub device into a repeater mode. The Red
LED blinks every 1 second to indicate a repeater mode. To turn the power off, use the
⑤
Power
switch at the bottom of the device. Repeater mode is enabled only if a constant power is supplied
by a power adaptor (5V / 1A DC power adaptor).
•
•
Pairing (Main WI-249LM/Repeater)
Press the
⑥
Volume switch on a repeater for 5 seconds to go in to pairing mode. The Red LED
blinks every 0.5 seconds to indicate that the repeater is in pairing mode. A sound of a double beep
indicates the pairing is completed. The pairing mode lasts for 60 seconds.
•
•
Paring (Repeater/Sub WI-249LS)
Press the 3Paging switch on a repeater for 5 seconds to go in to pairing mode. The Red LED blinks
every 0.5 seconds to indicate that the repeater is in pairing mode. A sound of a double beep
indicates the pairing is completed. The pairing mode lasts for 60 seconds.
Repeat the same method if more than one sub devices are to be paired with the repeater.
•
•
Red LED Indication When Setting Up a Repeater.
Red LED blinks every 1 second if the sub device is in Repeater mode.
•
•
Red LED Indication When Main Pages Sub Device
Red LED blinks every 0.05 seconds if the Main device pages sub devices including ones not paired
with a repeater.
•
•
Red LED Indication When Sub Pages Main Device
Red LED blinks every 0.05 seconds if the Sub device pages main device.
•
•
Factory Default Setting
To initiate a factory default setting, first turn off the device using the 5Power switch located at the
bottom of the device. Turn the power switch back on while pressing Paging button and Select
button simultaneously. The display blinks repeatedly every 0.1 second to indicate the device is in
factory default setting mode. Press the Volume switch to initiate the factory default setting. All data
is deleted and set with factory default setting.