1) Press the according button corresponding with the desired residence wished

to be called.

2) After the residence unit answers, conversation with the in-house unit can occur.

3) A “line busy” tone will sound if the residence unit is communicating with another

entrance panel unit.

1) Call duration lasts for 30 seconds.

2) Conversation duration lasts for 60 seconds.

3) If you wish to end a call/conversation, press the Call Button once more.

First set the ID number sequence for the multi-entry unit to “0 ”. After each multi-entry

panel has been installed, the user must program the building distributor's channels to

correspond with each multi-entry units' ID number, 1 to 4.

(CH1 

ID:1,  CH2 

ID:2,  CH3 

ID:3,  CH4 

ID:4)

If a multi-entry unit's ID is set to “0 ”, then it is in household registration mode.

(If a multi-entry unit's ID is set to “0”, then it is not in normal operation.)

1) On the back of the panel unit, you will find the DIP Switch board.

2) A multi-entry panel using the DIP Switches can be assigned from 1 to 3. 

3) When all 4-multi entry panels are installed, Dip switches setting for each

panel is as follows.

This is a video, button-type Multi-Entry unit connected to a building distributor

(CCU-BS) that can support up to 4 Multi-Entry units. It is also connected

to the floor distributor (CCU-FS), also powered by the CCU-BS, which can

connect 4 residences.

2. Part names and Functions

3. Calling In-house unite by resident Number

4. Call / Talk Time Duration

5. Multi-Entry Panel 

(

ID

)

Registration

No.

1

2

3

4

5

6

7

PART NAME

PART NAME

C-MIC

CCD Camera Lamp

CDS Sensor

CCD Camera

Speaker

Call Button

Name Card

Camera Angle adjusting knob

Connection terminal for Door Release

Volume control

RS-232 Program Download Terminal

Entry Panel ID setup dipswitch

Connection to terminal to CCU-BS

No.

8

9

10

11

12

13

Содержание DRC-nSB

Страница 1: ...the instructions to use your productexactly The company is not responsible for any safety accidents caused in abnormal operation of the product Model No DRC nSB nSC MULTI ENTRY UNIT a513 11 Sangdaewon...

Страница 2: ...e unite by resident Number Calling Talking Time Duration Multi Entry Panel ID Registration Setting Room Numbers to MASTER SLAVE Units Other Product Compattibility Resident Registration Program ButtonA...

Страница 3: ...ormal do not put the plug It may cause an electric shock or a fire Make sure that dust or foreign substances are not gathered on the product Make sure to prevent foreign substances from entering the p...

Страница 4: ...lding distributor CCU BD 7 Multi Entry panels require a power source of DC24V and DC28V if a separate power supply is needed to support more installation distance 8 All in house units Color videophone...

Страница 5: ...lti entry unit s ID is set to 0 then it is not in normal operation 1 On the back of the panel unit you will find the DIP Switch board 2 A multi entry panel using the DIP Switches can be assigned from...

Страница 6: ...om number registration mode 2 While picking up the handset of the in house videophone press the Extension Call and the Door Release buttons at the same time 3 Automatic communication is established be...

Страница 7: ...shown in the image above 8 The user is free to input different household numbers and alter existing registered numbers as desired 8 Resident Registration Program ButtonAsign zip This program is often...

Страница 8: ...the power is supplied from the building distributor If the distance between the building distributor and the Multi Entry panel is greater than 20m a separate power source RF 1A for Audio type Multi E...

Страница 9: ...4V DC28V 5A supplied from building distributor Wiring Power voltage Screen Dimension Standby 80mA Maximum Operation 295mA 5LUX 3LUX WhenpowerissuppliedfromBld Distributor 20m When power is supplied se...