1) Building Distributor: One Building distributor can be connected to up to 4

multi-entry panel units, outside distributor, floor distributor, GUARD or porter

(Dip switch setting number in a Building Distributor corresponds to its build number)

2) Floor Distributor: One floor distributor can be connectable up to 4 household

units per floor.

3) In-house Unit: A total of 2 in-house units, one MASTER unit and one SLAVE unit,

are connectable.

4) Guard (porter): From the in-house unit to the GUARD porter, call and

communication are possible.

(The GUARD porter is only capable of receiving incoming calls and CANNOT

make outgoing calls to individual rooms.)

6. Setting Room Numbers to MASTER, SLAVE Units

7. Other Product Compatibility

Setup will be established from the multi-entry panel connected to Channel 1.

In one room or household, there should only be one established MASTER

multi-entry unit. The remaining units should be set as SLAVE units.

Household 

From the room number registration number registration mode, pressing the Door 

Release button sets the unit as MASTER, and pressing the Extension Call button

sets the unit as SLAVE.

After completing registration of the room number, set the multi-entry unit's ID to “1”.

(If a multi-entry unit's ID is set to “0”, it is not in normal operation)

1. Setting the MASTER Unit

1) Set the ID to “0” for the multi-entry panel connected to Channel 1.

(For room number registration mode)

2) While picking up the handset of the in-house videophone, press the “Extension Call”

and the “Door Release” buttons at the same time.

3) Automatic communication is established between the multi-entry panel and

the in-house unit.

4) Then, press the “Door Release” button on the videophone while the call is being

made and an extended “bee” will sound signifying registration. 

At this time, press the assigned household number from the multi-entry panel.

Three, successive, beeps will sound to confirm successful registration.

5) Once the call is ended, the registration is complete.

(Repeat this process to register other room numbers.)

6) After registration is complete for all households, set the ID for each multi-entry

panel to “1”.  

2. Setting the SLAVE Unit

1) Set the ID to “0” for the multi-entry panel connected to Channel 1.

(For room number registration mode)

2) From the in-house unit, pickup the handset and press the Extension Call button

and the Door Release button at the same time.

3) Automatic communication is established between the multi-entry panel and

the in-house unit.

4) Then, press the “Extension Call” button on the videophone while the call

is being made and an extended “bee” will sound signifying registration. 

At this time, press the assigned household number from the multi-entry panel. 
Three, successive, beeps will sound to confirm successful registration.

5) Once the call is ended, the registration is complete.

(Repeat this process to register other room numbers.)

6) After registration is complete for all households, set the ID for each multi-entry

panel to “1”. 

Содержание DRC-nSB

Страница 1: ...the instructions to use your productexactly The company is not responsible for any safety accidents caused in abnormal operation of the product Model No DRC nSB nSC MULTI ENTRY UNIT a513 11 Sangdaewon...

Страница 2: ...e unite by resident Number Calling Talking Time Duration Multi Entry Panel ID Registration Setting Room Numbers to MASTER SLAVE Units Other Product Compattibility Resident Registration Program ButtonA...

Страница 3: ...ormal do not put the plug It may cause an electric shock or a fire Make sure that dust or foreign substances are not gathered on the product Make sure to prevent foreign substances from entering the p...

Страница 4: ...lding distributor CCU BD 7 Multi Entry panels require a power source of DC24V and DC28V if a separate power supply is needed to support more installation distance 8 All in house units Color videophone...

Страница 5: ...lti entry unit s ID is set to 0 then it is not in normal operation 1 On the back of the panel unit you will find the DIP Switch board 2 A multi entry panel using the DIP Switches can be assigned from...

Страница 6: ...om number registration mode 2 While picking up the handset of the in house videophone press the Extension Call and the Door Release buttons at the same time 3 Automatic communication is established be...

Страница 7: ...shown in the image above 8 The user is free to input different household numbers and alter existing registered numbers as desired 8 Resident Registration Program ButtonAsign zip This program is often...

Страница 8: ...the power is supplied from the building distributor If the distance between the building distributor and the Multi Entry panel is greater than 20m a separate power source RF 1A for Audio type Multi E...

Страница 9: ...4V DC28V 5A supplied from building distributor Wiring Power voltage Screen Dimension Standby 80mA Maximum Operation 295mA 5LUX 3LUX WhenpowerissuppliedfromBld Distributor 20m When power is supplied se...

Страница 10: ...Memo 16...

Отзывы: