background image

- 25-

15. Input Household number

P - Management PIN - E - 15 - E - Household Number - E-Multi Sub number - E 

This function is for inputting household number with lobby phone in case of a guard
station unit is not installed

Press the Program button (P).

Enter the Management PIN.

Press the 

Call button (E).

Household  PIN 

Entry Mode

Press the 

Call button (E).

Press the 

Call button (E).

Press the 

Call button (E).

Press the Program Number (15).

Lift up the receiver from the Household and press the Guard button to page the Main Entrance
Interphone, where the Household Number will be displayed. 
(Then, the displayed number must be changed for it is the default number from the factory.)

Enter the Household number and press the Page button (E).

ex) Entering as first

1234

ex) Entering as Unit 101

Enter the Multi Sub number and press the Page button (E).

Follow the same procedure to enter other Households.
Press the Cancel button (X) to end.

ex) Entering as Master

4 3 2 1

Содержание DRC-GAB

Страница 1: ...s caused by abnormal operation of the product Thank you for purchasing COMMAX products Please carefully read this User s Guide in particular precautions for safety before using a product and follow in...

Страница 2: ...e Building Management PIN 29 20 Appendix Various Program Summaries 30 21 How to use lobby phone 31 22 Wiring Method 32 22 Mscellaneous 36 23 Specifications 36 Table of Contents Thank you for purchasin...

Страница 3: ...ric shock fire when using a damaged power cable Please don t handle the power cable with a wet hand It may cause an electric shock Please plug out the power cable from the socket when not using it for...

Страница 4: ...e power cable Please don t use any chemical products such as wax benzene alcohol or cleanser Please don t drop the product on the ground and don t apply a shock It may cause a failure Please use the d...

Страница 5: ...No FUN No FUN 1 C MIC 2 CAMERA 3 SPEAKER 4 FND DISPLAY 5 RF ID 6 PROGRAM BUTTON 7 GUARD BUTTON 8 INPUT BUTTON 9 ELETRONIC KEY BUTTON 10 CANCEL BUTTON 11 CAMERA ANGLE 12 AJUSTMENT BUTTON 13 TALK VOLUME...

Страница 6: ...Button P Program This button is used to Program Electronic Key Button K Key This button is used to release the door by using PIN Available only when the Electronic Key option has been set as OFF When...

Страница 7: ...tton This button is used to reset the Building PIN or the Management PIN Change the message on FND To change the message on FND press the Program button P for 5 seconds 1 Displaying system version 010...

Страница 8: ...N Reenter using the Management PIN 2 3 Management PIN Press the Reset button Both the Building and the Management Building PINs are reset to default 3 All Remote Cardkey Deletion of 8 3 is to be used...

Страница 9: ...he common PIN for each main entrance By default this PIN is set as 1234 Management PIN shall be stated as Building PIN here below 4 2 Household PIN Each household has its own PIN By default this PIN i...

Страница 10: ...Press the Call button E Press the Program Number 0 Press the Call button E PASS will blink Enter the new PIN Press the Call button E Management PIN has been updated Press the Program button P Enter th...

Страница 11: ...ter the old PIN 4321 Press the Call button E Press the Program Number 1 Press the Call button E PASS will blink Enter the new PIN Press the Call button E Building PIN has been updated Press the Progra...

Страница 12: ...c Key button K Press the Program Number 20 Press the Call button E hono will blink Enter the Household Number Press the Call button E PASS will blink Enter the old Household PIN Press the Call button...

Страница 13: ...ton E Press the Program Number 16 Press the Call button E hono will blink Enter the Household Number The Household Number will be indicated Press the Call button E The Household PIN will be indicated...

Страница 14: ...umber Press the Call button Serial Number has been updated Press the Program button P Enter the Management PIN Press the Call button E Press the Program Number 3 Press the Call button E The Serial Num...

Страница 15: ...to the RF ID Receptor and the Card Number will appear on the Display Window FND Press the Cancel button X to end Remote Cardkey testing Press the Program button P Enter the Management PIN Press the Ca...

Страница 16: ...didn t register a card please delete all saved card referring to 8 5 chapter Caution Do not turn off the products within ten seconds after registering RF cards It might cause a problem in saving RF ca...

Страница 17: ...eck on the right side of the RF ID Card Or place the Card on top of the RF ID Receiver Press the Cancel button X to terminate the feature Press the Program button P Enter Management PIN Press the Call...

Страница 18: ...f the RF ID Card Or place the Card on top of the RF ID Receiver Press the Cancel button X to terminate the feature Press the Program button P Enter the Management PIN Press the Call button E Press the...

Страница 19: ...button E dEL will blink Press the Call button E again The number displayed on screen will change Press the Cancel button X to terminate the feature Press the Program button P Enter the Management PIN...

Страница 20: ...e Management PIN Press the Call button E Enter number 8 Monitor setting number for surveillance Press the Call button E Displaying previous setting on the screen Select a mode 0 Activate electronic ke...

Страница 21: ...ss the Call button E Previous selection is displayed Choose a time From 1 to 25 seconds Use numbers from 1 to 25 Press the Call button E Modification updated Press the Program button P Enter the Manag...

Страница 22: ...Line st Press the Program Number 21 Press the Call button E Previous selection is displayed Press the Call button E Enter the Management PIN Press the Program button P Press the Program button P Prog...

Страница 23: ...button E Press number 5 Page Signal Selection Press the Call button E Previous selection is displayed Select a page signal 0 Melody Tone 1 Bell Ringer Press the Call button E Page signal updated 12 Pa...

Страница 24: ...Selection Press the Call button E Previous selection is displayed Select a wiring method 0 0 Melody 1 Bell Ringer Press the Call button E Save new setting 13 The number of emitting chime setup Press...

Страница 25: ...nce P Building Management PIN E 6 E 0 E Short Distance P Building Management PIN E 6 E 1 E Long Distance By default the unit is set for short distance Do not change if possible Press the Program butto...

Страница 26: ...s the Call button E Press the Program Number 15 Lift up the receiver from the Household and press the Guard button to page the Main Entrance Interphone where the Household Number will be displayed The...

Страница 27: ...umerous videophones If only one videophone exists that unit shall be registered as the Master Press the Program button P Prog will appear Enter the Management PIN Press the Page button E Enter number...

Страница 28: ...button Press the Page button A paging tone will sound Wait for a reply Wait for a reply Press the page button A paging tone will sound Press the Call button E Press the Call button E ex unit 101 16 P...

Страница 29: ...usehold PIN Press the Page button Press the Page button Enter the Building or the Management PIN Press the Electronic key button Press the Electronic key button Press the Call button E Press the Call...

Страница 30: ...nagement PIN E 9 E Remote Cardkey Test 2 P Management PIN E 10 E Remote Cardkey Registration 3 P Management PIN E 11 E All Remote Cardkey Delete Household PIN Delete 4 P Management PIN E 12 E Individu...

Страница 31: ...er Press the Call button ex In case of household 101 Emit call sounds Opening door with household PIN Household number K household PIN E Press the household number Press the Household PIN Press the Ca...

Страница 32: ...22 Wiring Method 1 Lobby camera phone DRC GAC GAB 31...

Страница 33: ...2 System Schematic 32...

Страница 34: ...3 Terminal Board Wiring Diagram 33...

Страница 35: ...3 DRC GAC Expansion 34...

Страница 36: ...on Standby 200mA Max 500mA Conversation Hands free Lens B W C C D 1 3 Color CCD 1 4 Frequency 15 735KHz 60Hz 15 625KHz 50Hz Camera angle Horizon 68 Vertical 55 Minimum Illumination 0 1Lux within 300mm...

Страница 37: ...513 11 Sangdaewon dong Jungwon gu Seongnam si Gyeonggi do Korea Int l Business Dept Tel 82 31 7393 540 550 Fax 82 31 745 2133 Web site www commax com Printed In Korea 2010 09 103...

Отзывы: