. Installation
5
Note
①
Avoid the range of direct sunlight
②
Recommended height is pertinent
from 1450 ~ 1500mm
③
Avoid the installation near magnetic
activity, humid temperatures and gas
If you use UTP CABLE[CAT.5], connect
4 lines between monitor and interphone.
the rest 4 lines to GND after connecting
DOOR CAMERA & INTERPHONE Wiring
6. Operation
5
Each device should be connected by
If you use UTP CABLE[CAT.5] for
separated cables.
CAMERA1and CAMERA2, 2 lines of UTP
cable are required.
Monitor
Camera
Monitor
Interphone
UTP Cable
UTP Cable
※
To display firmware version on the screen, press [
▽
] button
※
To reset to PAL mode, press the [Select] button and [
▽
] button at the same time.
※
To reset to NTSC mode, press the [Select] button and [
△
] button at the same time.
Note :
When it is reset to PAL or NTSC, all saved data is deleted and language setting is
changed as English
Note :
When install CCTV camera, video standard(PAL or NTSC) must be same with
installed door camera
Note
: Only Camera 1 is available in factory default setting condition. In order to use
camera 2, jumper cap should be removed to activate no. 21 port.
※
Volume control button: It is to adjust talking volume from counter side.
※
Calling sound level control button: It is to adjust calling sound
※
Screen resolution Button: Set the screen status at MENU -> GUI setting
※
Usage of camera 2(refer to no. 21 on above drawing): In order to use 2
nd
camera,
jumper cap should be removed to activate no. 21 port.