background image

Visit our website for more details

www.CommandAccess.com

U.S. Customer Support

1-888-622-2377

Canada Customer Support

1-855-823-3002

T E C H N I C A L   I N F O R M A T I O N

MM4 S

witcheS

PTS Video

Click or Scan

2 Beeps

3 Beeps

5 Beeps

6 Beeps

B

eepS

e

xplanation

S

olution

Over Voltage

Under Voltage

Retraction or Dogging 

failure

Push to Set

> 30V unit will shut down. Check voltage & adjust to 24 V.

< 20V unit will shut down. Check voltage & adjust to 24 V. 

Device physically binding during retraction or pulled from the dogged position.

Device is recording it’s new position and power mode after the 6th beep.

t

rouBleShooting

 & D

iagnoSticS

4 Beeps

Failed Sensor

Verify all 3 sensor wires are installed correctly. Replace sensor if problem 

persists by contacting office.

Step 1

-

Press the device push pad to the desired setting. (Recommend to fully depress and 
release 5%, giving the device a little room for changing door conditions.)

Step 2

-

 While depressing the push pad, apply power. (i.e. presenting the credential to the 
reader).

Step 3

-

 Continue to keep pad depressed, the device will beep 6 times. After the 
beeps have stopped, release the pad and now the adjustment is complete. 
If not to your liking repeat the three steps. That’s all there is to it. 

S

etting

 ptS

Make sure to set PTS before finishing installation!

**

Important Info

**

•  Input Voltage:  24VDC +/- 10%

•  Wire gauge:  Minimum 18 gauge

•  Average Latch Retraction Current:  2 Amp

•  Average Holding Current:  250 mA

High Torque Mode

•  Average Latch Retraction Current: 600 mA

•  Average Holding Current:  150 mA

Low Torque Mode

1.  After 1

st

 fail: 5 beeps then immediately attempts to retract again.

2.  After 2

nd

 fail: 5 beeps with pause in-between for 30 seconds then device 

attempts to retract again.

3.  After 3

rd

 fail: 5 beeps every 7 minutes, device will not attempt to retract.

To Reset: Depress bar for 5 seconds at any time.

ON

OFF

OFF

OFF
ON

OFF

Low Torque
Standard Torque

PTS programming locked

ON ON High Torque

1

S

witch

 

p

rogram

2

•  Average Latch Retraction Current: 900 mA

•  Average Holding Current:  215 mA

Standard Torque Mode- S

hipS

 S

tandard

S

pecificationS

Add MM4S Program 

sticker

Содержание SLP-UL-M-KIT

Страница 1: ...23 3002 A Kit Includes A 1 Motor Mount Assembly w MM4S series module B 2 Phillips Screws C 1 Push Go Connector D 1 MM4S switch program sticker E 1 5 64 Hex Wrench F 1 5 32 Drill Bit G 1 8 Lead w VD Connector Tools Required Power Drill The Command Access SLP UL M KIT is a field installable motorized latch pullback kit for the Sargent 80 series B C D E E Scan or Click here Installation Video F G ...

Страница 2: ...e push pad apply power i e presenting the credential to the reader Step 3 Continue to keep pad depressed the device will beep 6 times After the beeps have stopped release the pad and now the adjustment is complete If not to your liking repeat the three steps That s all there is to it Setting PTS Make sure to set PTS before finishing installation Important Info Input Voltage 24VDC 10 Wire gauge Min...

Страница 3: ...NTROL SYSTEM NO VOLTAGE LOCKING HARDWARE CAT Electrified Exit Device Installation Example Recommended Power Supplies All Command Access exit devices field installable kits have been thoroughly cycle tested with Command Access power supplies at our factory For more information click here or go to our website ...

Страница 4: ...STEP 1 Disassemble Exit Device A Remove End Cap Filler Plate B Remove 4 screws from baserail C Partially slide push pad off approx 2 3 D Using 5 32 drill bit Open up the 2 back screw holes 3 4 ...

Страница 5: ...STEP 2 Install Motor Mount A Attach the link assembly to the end of the activating bracket Next place activating bracket into center of the motor mount C Re install metal rod securing activating bracket to motor mount B Secure link assembly to activating bracket with Hex wrench provided Activating Bracket Metal Rod AB Mount Link Assembly Baserail ...

Страница 6: ...ired setting Recommend to fully depress and release 5 giving the device room for changing door conditions Step 2 While depressing the push pad apply power i e Presenting the credential to the reader Step 3 Continue to keep pad depressed the device will beep 6 times After the beeps have stopped release the pad and now the adjustment is complete If not to your liking repeat the 3 steps Setting PTS S...