background image

22901 La Palma Ave, Yorba Linda, CA 92287 www.commandaccess.com

PM300UNIV

Installation instructions

PM300 Instructions Rev. 1.0   Page 1

Overview of Product

The PM300 is a power booster interface module that fits inside of an electric latch pullback exit device. When installed in the exit device 

it typically allows for a much longer wire run from the power supply to the exit device (typically up to 700’ with 18/2 wire) than the exit 

device manufacturer’s original recommendations. This is great solution for projects that were pre-wired with too thin of a gauge wire or 

where a discerning architect wants all the power supplies consolidated in a central room for simplified maintenance.   Additionally, this is a 

great solution when the original exit device manufacturer’s power supply is not available or is cost prohibitive.  

  

Here’s how the PM300 works – When the exit device is triggered, the power supply sends power to quickly charge the PM300.  Within 

500ms, the PM300 releases its high current pulse to the exit device solenoid giving it what it needs to retract the latch bolt. Once the latch 

bolt is retracted, the PM300 switches to the Pulse Width Modulation (PWM) mode that reduces the current and allows the solenoid to 

remain energized continuously, if desired.  This unit is also equipped with a mode switch that allows the option of High Output mode for 

those applications the require a higher pulse (special power supply required).  

Specifications:

   

Operating Voltage Range: 26.5V +/-15% 

 

 

 

Wires:   Input to PM300 non-polarized Black (+), Black (-) 

 

 

 

 

Output from PM300: Yellow=Pull Coil; Orange= Hold Coil; Green=Common 

 

 

 

Relays:   We recommend that minimum 5A relays are used with the PM300 when used with  

 

 

 

 

 

 

power supplies other than those listed below.

Power Supply Options for 

PM300UNIV

 and 

PM300UNIV-D

 in Standard Mode: 

The PM300 works best with the Command Access PS1N, PS2, PS2BB & all PS5 series regulated power supplies. The PM300 will also work 

with most Regulated power supplies rated at 24VDC and 1.5A or higher. Although we do not recommend using power supplies that we 

have not thoroughly tested with the PM300, if you choose to do so anyway we recommend you consider the following:

Wires directly to the solenoid for most solenoid activately devices.  Adapter cables are offered 

for numerous manufactures, such as, Adams Rite, Corbin/Yale, Precision, and more.

Models:

If the output fuses are glass type, they will need to be rated at minimum of 3.5 A. If the fuses are the resetable type, they should 

have a trip rating of 1Amp or higher and a hold of a 1/2 Amp or greater.  

(

If these values are not listed, the power supply manufacturer should be able to give you this information.  We recommend that you consult with the power supply 

manufacturer to confirm that if replacing the fuses with a higher value is necessary that doing so will not damage the power supply or create any kind of safety risk)

(Note: Not compatible with Adams Rite, Dorma, Yale, Corbin Russwin, Precision latch retraction power supplies)

2.

1.  The Regulated power supply should be rated 24VDC at 1.5 Amps or higher. 

**Use of this item may void other factories warranties**

Comments? Please email us at [email protected]

or call us: 1-888-622-2377 (6-ACCESS)

PM300UNIV

**Command Access is not a licensee, or affiliated, associate or connected with Ingersol Rand, Assa Abloy, Dorma, Stanley 

Security Solutions, Schlage, Cal Royal, Corbin Russwin, Precision, Sargent**

Power Supply Options for 

PM300UNIV 

and 

PM300UNIV 

in High Output Mode:

In High Output mode, the PM300 is design to be powered by the Command Access PS1N, PS5-4, and PS5-6 power supplies only. 

PM300UNIV-D

-  Sames as PM300UNIV above with the added feature of a .5 second delay. 

Содержание PM300UNIV

Страница 1: ...Power Supply Options for PM300UNIV and PM300UNIV D in Standard Mode The PM300 works best with the Command Access PS1N PS2 PS2BB all PS5 series regulated power supplies The PM300 will also work with most Regulated power supplies rated at 24VDC and 1 5A or higher Although we do not recommend using power supplies that we have not thoroughly tested with the PM300 if you choose to do so anyway we recom...

Страница 2: ...the power from the power supply The harness should be connected to the positive and negative leads from the power supply Generic examples and specific retrofits are shown below Power transfer from hinge jamb to exit device A power transfer hinge or door loop may be used provided the wire gauge meets or exceeds 22 gauge Wire Run Guidelines For best results we recommend that your maximum wire run no...

Страница 3: ...d wires from solenoid Next connect Black wire from harness to Black wire from solenoid Step 3 Step 1 Step 2 PM300 Step 4 Connect wiring harness to PM300 module Cable Black PM300 Green Remove pushbar and separate push pad from device to gain access to the solenoid circuit board assembly Adams Rite wire connections instructions Connect white and red wire from the solenoid to white wire from the cabl...

Страница 4: ...Red primary solenoid wire to White harness wire Next connect Black primary solenoid wire to Black harness wire Disregard the two Secondary Black wires PM300 PM300 Remove Circuit Board Corbin Russwin wire connections instructions Precision wire connections instructions Cut wires from board and remove circuit board from bar Step 1 Step 1 Step 1 Step 2 Step 3 Connect harness wire to PM300 Module Step...

Отзывы: