Command access PM300UNIV Скачать руководство пользователя страница 4

Primary WHITE

Primary WHITE

Position Switch BLACK

PHI Harness

Harness White (PM300 Yellow)

Harness  Black (PM300 Green)

Position Switch BLACK

PHI pushpad and housing

PM300 Instructions Rev. 1.0   Page 4

Primary

Solenoid

Secondary

Solenoid

Red 1

Black 1

Black 2

Black 2

Primary Red

Primary Black

Secondary Black

Secondary Black

Corbin/Yale Harness

HarnessWhite (PM300 -UNIVYellow)

Harness Black (PM300-UNIVGreen)

Remove pushbar and separate push pad from device to gain access to the solenoid/circuit board assembly.

Connect Red primary solenoid wire to White harness wire. Next, connect Black primary solenoid wire to Black harness wire. Disregard the 

two Secondary Black wires

PM300

PM300   

Remove Circuit  Board

Corbin/Russwin wire connections instructions:

Precision wire connections instructions:

Cut wires from board and remove circuit board from bar. 

Step 1.  

Step 1.  

Step 1.  

Step 2.  

Step 3.  

Connect harness wire to PM300 Module.

Step 1.  

Connect upper White solenoid wire to White harness wire. Next connect lower white solenoid wire to Black harness wire. Disregard the two 

Position switch Black wires

Step 2.  

Connect harness wire to PM300 Module.

Remove pushbar and separate push pad from device to gain access to the solenoid/circuit board assembly.

Содержание PM300UNIV

Страница 1: ...Power Supply Options for PM300UNIV and PM300UNIV D in Standard Mode The PM300 works best with the Command Access PS1N PS2 PS2BB all PS5 series regulated power supplies The PM300 will also work with most Regulated power supplies rated at 24VDC and 1 5A or higher Although we do not recommend using power supplies that we have not thoroughly tested with the PM300 if you choose to do so anyway we recom...

Страница 2: ...the power from the power supply The harness should be connected to the positive and negative leads from the power supply Generic examples and specific retrofits are shown below Power transfer from hinge jamb to exit device A power transfer hinge or door loop may be used provided the wire gauge meets or exceeds 22 gauge Wire Run Guidelines For best results we recommend that your maximum wire run no...

Страница 3: ...d wires from solenoid Next connect Black wire from harness to Black wire from solenoid Step 3 Step 1 Step 2 PM300 Step 4 Connect wiring harness to PM300 module Cable Black PM300 Green Remove pushbar and separate push pad from device to gain access to the solenoid circuit board assembly Adams Rite wire connections instructions Connect white and red wire from the solenoid to white wire from the cabl...

Страница 4: ...Red primary solenoid wire to White harness wire Next connect Black primary solenoid wire to Black harness wire Disregard the two Secondary Black wires PM300 PM300 Remove Circuit Board Corbin Russwin wire connections instructions Precision wire connections instructions Cut wires from board and remove circuit board from bar Step 1 Step 1 Step 1 Step 2 Step 3 Connect harness wire to PM300 Module Step...

Отзывы: