background image

PM300 Instructions Rev. 1.0   Page 3

Primary

Solenoid

Remove Circuit  Board

Primary

Solenoid

Cut wires from Adams Rite Circuit board and remove 

board.

Tape back two Blue. 

Connect White wire from harness to White and Red wires from solenoid. 

Next, connect Black wire from harness to Black wire from solenoid.

Step 3.

Step 1.

Step 2.

PM300 

 

Step 4.   Connect wiring harness to PM300 module.

Cable Black (PM300-Green)

Remove pushbar and separate push pad from device to gain access to the solenoid/circuit board assembly.

Adams Rite wire connections instructions:

Connect white and red wire from the solenoid 

to white wire from the cable(PM300-Yellow)

Содержание PM300UNIV

Страница 1: ...Power Supply Options for PM300UNIV and PM300UNIV D in Standard Mode The PM300 works best with the Command Access PS1N PS2 PS2BB all PS5 series regulated power supplies The PM300 will also work with most Regulated power supplies rated at 24VDC and 1 5A or higher Although we do not recommend using power supplies that we have not thoroughly tested with the PM300 if you choose to do so anyway we recom...

Страница 2: ...the power from the power supply The harness should be connected to the positive and negative leads from the power supply Generic examples and specific retrofits are shown below Power transfer from hinge jamb to exit device A power transfer hinge or door loop may be used provided the wire gauge meets or exceeds 22 gauge Wire Run Guidelines For best results we recommend that your maximum wire run no...

Страница 3: ...d wires from solenoid Next connect Black wire from harness to Black wire from solenoid Step 3 Step 1 Step 2 PM300 Step 4 Connect wiring harness to PM300 module Cable Black PM300 Green Remove pushbar and separate push pad from device to gain access to the solenoid circuit board assembly Adams Rite wire connections instructions Connect white and red wire from the solenoid to white wire from the cabl...

Страница 4: ...Red primary solenoid wire to White harness wire Next connect Black primary solenoid wire to Black harness wire Disregard the two Secondary Black wires PM300 PM300 Remove Circuit Board Corbin Russwin wire connections instructions Precision wire connections instructions Cut wires from board and remove circuit board from bar Step 1 Step 1 Step 1 Step 2 Step 3 Connect harness wire to PM300 Module Step...

Отзывы: