PM300 Instructions Rev. 1.0 Page 3
Primary
Solenoid
Remove Circuit Board
Primary
Solenoid
Cut wires from Adams Rite Circuit board and remove
board.
Tape back two Blue.
Connect White wire from harness to White and Red wires from solenoid.
Next, connect Black wire from harness to Black wire from solenoid.
Step 3.
Step 1.
Step 2.
PM300
Step 4. Connect wiring harness to PM300 module.
Cable Black (PM300-Green)
Remove pushbar and separate push pad from device to gain access to the solenoid/circuit board assembly.
Adams Rite wire connections instructions:
Connect white and red wire from the solenoid
to white wire from the cable(PM300-Yellow)