ComfortStar CPP012CD(O) Скачать руководство пользователя страница 10

9

installation manual 

6.1   Installation Place 

6.    OUTDOOR UNIT INSTALLATION

There is enough room for installation and maintenance. 
The air outlet and the air inlet are not impeded, and can 

not be reached by strong wind. 
It must be a dry and well ventilating place. 
The  support  is  flat  and  horizontal  and  can  stand  the 

weight of the outdoor unit. And will no additional noise or 

vibration. 
Your  neighborhood  will  not  feel  uncomfortable  with  the 

noise or expelled air. 
It is easy to install the connecting pipes or cables. 
Determine the air outlet direction where the discharged air 

is not blocked. 
There is no danger of fire due to leakage of inflammable 

gas. 
The piping length between the outdoor unit and the indoor 

unit may not exceed the allowable piping length. 
In the case that the installation place is exposed to strong 

wind  such  as  a  seaside,  make  sure  the  fan  operating 

properly  by  putting  the  unit  lengthwise  along  the  wall  or 

using a dust or shield.

(Refer to Fig.6-1)

 

If  possible,  do  not  install  the  unit  where  it  is  exposed  to 

direct sunlight.  
If necessary, install a blind that does not interfere with the 

air flow. 
During  the  heating  mode,  the  water  drained  off  the 

outdoor unit ,The condensate should be well drained away 

by  the  drain  hole  to  an  appropriate  place,  so  as  not  to 

interfere other people.  
Select  the  position  where  it  will  not  be  subject  to  snow 

drifts, accumulation of leaves or other seasonal debris. If 

unavoidable, please cover it with a shelter. 
Locate  the  outdoor  unit  as  close  to  the  indoor  unit  as 

possible. 
If possible, please remove the obstacles nearby to prevent 

the  performance  from  being  impeded  by  too  little  of  air 

circulation. 
The  minimum  distance  between  the  outdoor  unit  and 

obstacles  described  in  the  installation  chart  does  not 

mean  that  the  same  is  applicable  to  the  situation  of  an 

airtight  room.  Leave  open  two  of  the  three  directions 

(M,N,P) 

(Refer to Fig.6-5) 

t r o 

n g 

  w 

i n 

The  outdoor  unit  should  be  installed  in  the  location  that 

meets the following requiements: 

All  the  pictures  in  this  manual  are  for  explanation 

purpose  only.  They  may  be  slightly  different  from  the 

air  conditioner  you  purchased(depend  on  model).The 

actual shape shall prevail. 

 

Fig.6-1

NOTE 

1. Split type outdoor unit 

6.2   Figure of body size 

A

B

D

Содержание CPP012CD(O)

Страница 1: ...PA 12 TPA 18 TPA 24 TPA 36DU TPA 48DU Outdoor Unit CPP009CD O CPP012CD O CPP018CD O CPP024CD O CPP036CD O DU CPP048CD O DU If used as MULTI unit please refer to the Installation operation manuals pack...

Страница 2: ...strong and firm location which is able to withstand the set s weight If the strength is not enough or installation is not properly done the set will drop to cause injury The appliance must be installe...

Страница 3: ...not be sufficient enough to eliminate the noise The appliance is not intended for use by young children or infirm persons without supervision Don t install the air conditioner in the following locatio...

Страница 4: ...vement without further notices Cautions on remote controller installation Remote controller Remote controller holder Mounting screw B ST2 9x10 C H CANCEL LOCK SET TEMPERATURE C AUTO COOL DRY HEAT FAN...

Страница 5: ...INSPECTING AND HANDLING THE UNIT At delivery the package should be checked and any damage should be reported immediately to the service agent When handling the unit take into account the following 5...

Страница 6: ...y by wrenching the nuts after having adjusted the body s position well Refer to Fig 5 5 Select the position of installation hooks according to the hook holes on the installation board positions on the...

Страница 7: ...our corners if the lift of the indoor unit and the drainpipe is not influenced Refer to Fig 5 13 right Hang the air in grill to the panel then connect the lead terminator of the swing motor and that o...

Страница 8: ...ge test Check whether the drainpipe is unhindered New built house should have this test done before paving the ceiling The unit with pump Remove the test cover and stow about 2000ml water to the water...

Страница 9: ...g 5 19 Fig 5 18 One way Two way In case of one duct connection In case of two duct connection NOTE Fig 5 17 5 4 Install the distribution duct Conditioned air can be distributes by means of a distribut...

Страница 10: ...direct sunlight If necessary install a blind that does not interfere with the air flow During the heating mode the water drained off the outdoor unit The condensate should be well drained away by the...

Страница 11: ...lve of vacuum meter 2 Cut off the connection between pressure meter and vacuum pump 3 Close the vacuum pump Fig 6 7 NOTE All the pictures in this manual are for explanation purpose only They may be sl...

Страница 12: ...ell with the tapes to prevent leakage Execute heat insulation work completely on both sides of the gas piping and the liquid piping Otherwise this can sometimes result in water leakage 1 2 3 5 6 7 4 B...

Страница 13: ...orque N M Turn clockwise to close Stop Valve size Shaft valve body Cap Valve lid 6 4 5 4 6 6 Hexagonal 13 5 16 5 11 5 13 9 9 5 12 7 8 1 9 9 18 22 15 9 13 5 16 5 Hexagonal 23 27 22 2 27 33 Hexagonal wr...

Страница 14: ...ion 3 The drain plug is used to empty the water receiver for maintenance of the air conditioner Please stuff it imposition at all times during operation to avoid leakage The body s pump pipe and the d...

Страница 15: ...ment has to be connected with this power line For detailed installation acceptance please refer to your power supplier if restrictions do apply for products like washing machines air conditioners or e...

Страница 16: ...impeded The heating insulation works well The ground wiring is connected correctly The length of the tubing and the added stow capacity of the refrigerant have been recorded The power voltage fits the...

Страница 17: ...ding to the wiring scheme or it damages the unit Before obtaining access to terminals all supply circuits must be disconnected CAUTION Indoor Outdoor connection The power supply must comply with the r...

Страница 18: ...ls TECHNICAL BULLETIN Heat Sink Compound Thermal Paste Make sure to use Heat Sink Compound not provided when replacing Mini Split electronic boards Clean up thoroughly old paste on chips located under...

Отзывы: