background image

3. Frequency limited 

If

Ǐ

T

Limited frequency temperature of module

ǐ

≤T

Module

˘Ǐ

T

frequency reducing temperature at normal speed of module

ǐ

, you should limit the 

frequency raising of compressor. 

4. Reducing frequency at normal speed and power turn-off: 

If

Ǐ

T

frequency reducing temperature at normal speed of module

ǐ

≤T

Module

˘Ǐ

T

frequency reducing temperature at high speed of module

ǐ

, you should 

adjust the compressor frequency by reducing 8Hz/90s till the lower limit; After it was running 90s at the lower limit, 
if

Ǐ

T

frequency reducing temperature at normal speed of module

ǐ

≤T

Module

, you should stop the machine for module overheating 

protection;

5. Reducing frequency at high speed and power turn-off: 

If

Ǐ

T

frequency reducing temperature at high speed of module

ǐ

≤T

Module

˘Ǐ

T

Power turn-off temperature of module

ǐ

you should adjust the 

compressor frequency by reducing 30Hz/90s till the lower limit; After it was running 90s at the lower limit, if 

Ǐ

T

frequency reducing temperature at normal speed of module

ǐ

≤T

Module

, you should stop the machine for module overheating 

protection;

6. Power turn-off:

If the 

Ǐ

T

Power turn-off temperature of module

ǐ

≤T

Module

, you should stop the machine for module overheating protection; If 

T

Module

˘Ǐ

T

Limited frequency temperature of module

ǐ

and the compressor has been stopped for 3 minutes, the machine 

should be allowed to operate.     
7. If the discharging temperature protection of compressor continuously occurs for six times, it should not be 
resumed automatically, and you should press the ON/OFF button to resume. During the process of running, if the 
running time of compressor exceeds the 

Ǐ

t

Protection times clearing of module

ǐ

, the discharge protection is cleared to 

recount. Stopped or transferred to supply air mode will clear the trouble times immediately (if the trouble can not 
be resumed, mode transferring also will not clear it). 

(9) Compressor overloads protection   

If you measure the compressor overload switch action in 3s, the compressor should be stopped for overloading. 
The machine should be allowed to operate after overload protection was measured to resume. 
If the overloading protection continuously occurs for three times, it should not be resumed automatically, and you 
should press the ON/OFF button to resume. The protection times of compressor is allowed to clear after the 
compressor run

Ǐ

t

Protection times clearing of compressor overloading

ǐ

30 minutes. 

(10) Phase current overcurrent protection of compressor 

During the running process of compressor, you could measure the phase current of the compressor, and control 
it according to the following steps: 

1. Raising the frequency slowly: 

During the process of raising phase current and frequency of compressor, if the 

Ǐ

I

Slowly raising frequency phase current

ǐ

≤I

Phase current

˘Ǐ

T

Limited frequency phase current

ǐ

, the frequency raising speed should be executed according to the 

Ǐ

F

Preventing protection frequency raising speed

ǐ

; If I 

Phase current

˘Ǐ

I

Slowly raising frequency phase current

ǐ

, you should exit the slowly raising 

control.

2. Frequency limited 

If

Ǐ

I

Limited frequency phase current

ǐ

≤I

Phase current

˘Ǐ

T

frequency reducing phase current

ǐ

, you should limit the frequency raising of 

compressor. 

3. Reducing Frequency   

If [I 

Frequency Reducing Phase Current

]≤I

Phase Current

˘

[I 

Power Turn-Off Phase Current

], the compressor shall continue to reduce 

frequency till the lowest frequency limit or out of the condition of reducing frequency; 

4. Power turn-off 

If I 

Phase Current

≥[I

Power Turn-Off Phase Current

], the compressor phase current shall stop working for overcurrent protection; 

if I 

Phase Current

≤[I

Frequency Reducing Phase Current

], and the compressor have stopped working for 3 min, the machine shall 

be allowed to operate; 
5. If the overcurrent protection of compressor phase current continuously occurs for six times, it should not be 
resumed automatically, and you should press the ON/OFF button to resume. During the process of running, if the 
running time of compressor exceeds the 

Ǐ

t

Clearing Time of Compressor Phase Current Times

ǐ

, the overcurrent protection is 

cleared to recount. 

(11) Starting-up Failure Protection for Compressor 

Stop the compressor after its starting-up fails, restart it after 20s if the fault doesn’t shows, and if they are all 
failing for the successive start 3 times, it shall be reported as Starting-up Failure, and then restart up it after 3 min. 
When it still not be able to operate through carry out the above process for 5 times, it is available if press ON/OFF. 
And the compressor should be cleared the times after it run 2 min. 

(12) Out-of-Step Protection for Compressor 

The out-of-step protection signal should be detected immediately after starting-up compressor, and once find the 
out-of-step protection signal, the out-of-step protection shall be stopped; if it can run for lasting power turn-off 3 
min, the machine shall be allowed to operate. 

Содержание CARAT18-CD

Страница 1: ...1 Summary and features Summary and features SERVICE MANUAL FOR 23SEER DIAMOND SPLITS CARAT18 CD CARAT24 CD...

Страница 2: ...r W Fuse A Sound Pressure Level dB A H M L Sound Power Level dB A H M L Dimension W H D mm Dimension of Package L W H mm Net Weight Gross Weight kg 2 CARAT18 CD 208 230V 60Hz 830 750 650 550 13 18 2 5...

Страница 3: ...enser Pipe Diameter mm Rows Fin Gap mm Electric expand valve Overload Protector Throttling Method Starting Method Working Temp Range Compressor Type L R A A Compressor RLA A Compressor Power Input W O...

Страница 4: ...odel Output of Swing Motor W Fuse A Sound Pressure Level dB A H M L Sound Power Level dB A H M L Dimension W H D mm Dimension of Package L W H mm Net Weight Gross Weight kg CARAT24 CD 208 230V 60Hz 10...

Страница 5: ...ser Pipe Diameter mm Rows Fin Gap mm Electric expand valve Overload Protector Throttling Method Starting Method Working Temp Range Compressor Type L R A A Compressor RLA A Compressor Power Input W Out...

Страница 6: ...Outdoor unit Wall Pipe Drainage hose Air in Air out Wrapping Tape Connection pipe Air inlet Front Panel Displayer Air outlet Filter Guide panel Wireless remote control Displayer Setting temp Heating C...

Страница 7: ...installation dimensions of indoor unit 4 Outline and installation dimension Outline and installation dimension W D H Dimension Applicable models Unit mm Ceiling Right Tube exit Sign Left Tube exit Sig...

Страница 8: ...Outline and installation dimensions of outdoor unit Bolt Wrench Nut Dimension Applicable models Unit mm...

Страница 9: ...Electrical circuit diagram Electrical circuit diagram 5 5 5 5 5 These circuit diagrams are subject to change without notice please refer to the one supplied with the unit INDOOR UNIT OUTDOOR UNIT...

Страница 10: ...range should be 16 30 61 86 Fahrenheit scale 2 Working condition and procedure of heating mode When unit turn on and enter into Heating mode indoor unit enter into anti cool wind mode when unit is st...

Страница 11: ...tate Display Table Note in the case that the unit is switched off with the remote controller or the compressor is switched on again failure display waiting time 200s shall be cleared 4 Frequency limit...

Страница 12: ...on state the system will continue to operate if timing start is set when the system is at stop as the preset time is reached the system will start to run in preset mode Timing stop if timing stop is s...

Страница 13: ...ced Running Function of the Inner Units 1 Enter into Forced Running Control Within 5 minutes after power up press the Lights Off button on the remote controller continuously for three times within 3 s...

Страница 14: ...temperature changes When running with force the outdoor fans shall run in the highest air flow 1 Outer fans control logic in cooling dehumidifying mode 1 If Toutdoor ambient temperature Tinlet tempera...

Страница 15: ...eiving the order of power turn on or preheating it will carry out charging control at first 2 Charging stops Charging will stop if meet the two following conditions a The preheating of compressor has...

Страница 16: ...pping the machine or transferring to supply air will clear the trouble times immediately if the trouble can not be resumed mode transferring will not clear it 2 Overload protection function Overload p...

Страница 17: ...it was running 90s at the lower limit if T heating overload frequency reducing temperature at normal speed T outer pipe then Cooling overload protects machine stopping 4 Power turn off If the T heati...

Страница 18: ...overcurrent and the compressor has been stopped for 3 minutes the machine should be allowed to operate 5 If the overcurrent protection continuously occurs for six times it should not be resumed automa...

Страница 19: ...t Protection times clearing of compressor overloading 30 minutes 10 Phase current overcurrent protection of compressor During the running process of compressor you could measure the phase current of...

Страница 20: ...cleared out the failure and its times immediately when turning off or delivering wind cooling dehumidifying mode conversed the inverted mode don t clear out the failure when it can t recover to operat...

Страница 21: ...button for 2 seconds above in every 0 5 seconds the value on ten place ofMinutewillbeincreased1 Duringblinking repress the Clock button signalwillbe constantly displayed and itdenotesthe setting succe...

Страница 22: ...n its signal will be displayed When switching the mode or changing fan speed this function will be canceled automatically Notice This is a general use remote controller it could be used for the air co...

Страница 23: ...at all five positions SWING UP and DOWN BUTTON Timer On setting Signal ON will blink and display signal will conceal the numerical section will become the timer on setting status During 5 seconds blin...

Страница 24: ...e not available for some units 4 Press TURBO button can realize the ON and OFF of TURBO function or timer off This function indicates that moisture on evaporator of indoor unit will be blowed after th...

Страница 25: ...ontroller will display H1 If switch to heat mode the position will display H1 which flickers for 5s in which case press button H1 will disappear and setting temp be displayed After remote controller i...

Страница 26: ...or light off If cancel the light function the mark will disap per on the remote controller screen by pressing this button In which case the displayer indicator light will be off if the AC receives thi...

Страница 27: ...Exploded View of Components and Parts of Indoor unit 7 Explosive view and spare parts list Explosive view and spare parts list CARAT18 CD I...

Страница 28: ...rainage hose 1 37 Rubber Plug Water Tray 1 38 Axile Bush 1 39 Jumper 1 40 Display Cover 2 1 41 Display Board 1 42 Shield cover of Electric Box 1 43 Ambient Temperature Sensor 1 44 Tube Sensor 1 45 Ele...

Страница 29: ...Exploded View of Components and Parts of outdoor unit CARAT18 CD O...

Страница 30: ...31 Wire Clamp 1 1 32 Wire Clamp 2 1 33 Insulation GasketC 1 34 Terminal Board 1 35 Terminal Board support Assy 1 36 Electric Box 1 37 Radiator 1 38 Electric expand valve fitting 1 39 Electronic Expans...

Страница 31: ...Exploded View of Components and Parts of Indoor unit CARAT24 CD I...

Страница 32: ...Holder 1 40 Fan Bearing 1 41 O Gasket of Cross Fan Bearing 1 42 O Gasket sub assy of Bearing 1 43 Rem ote Controller 1 44 Electric Box Assy 1 45 Display Board 1 46 Jum per 1 47 Electric Box 1 48 Tube...

Страница 33: ...Exploded View of Components and Parts of outdoor unit CARAT24 CD O...

Страница 34: ...lectric Box 1 35 Radiator 1 36 Electric Box Assy 1 37 Cut off Valve liquid 1 38 Electronic Expansion Valve 1 39 Electric expand valve fitting 1 40 4 way Valve Assy 1 41 Sensor Container 1 42 Magnet Co...

Страница 35: ...nd the remote startup has no response The remote controller does not receive signals after it is powered the buzzer will sound unless it has malfunction The circuit or the part of the air conditioner...

Страница 36: ...e thick and thin pipes is good Heat insulation must also be provided for the joint andthe exposed part of the copper pipe Block of outdoor heat ex changer Clean the dust accumulated on the surface of...

Страница 37: ...pacitor of compressor Replace the capacitor The voltage is too low or too high Manostat is recommended Wrong wire connection Connect the circuit diagram correctly When cooling or heating outdoor fanru...

Страница 38: ...Touch of pipeline of outdoor unit Separate the touching pipeline Touch of inner plates Louver of outdoor unit touched outer case Abnormal sound inside compressor Change compressor Adjust location of...

Страница 39: ...Note When replacing the controller make sure insert the wire jumper into the new controller otherwise the unit display C5 Indoor PC Board...

Страница 40: ...Front Side Indoor PCB 1 2 healthy function neutral wire 3 4 5 PG 6 7 8 To be conected with Swing Motor 9 PG 10 20k 25o C 15k 25o C 11 12...

Страница 41: ...Back side VIEW 1 2 PG 3 4 5 MCU 6 7...

Страница 42: ...Test1 5V Test2 Test3 Test4 The key testing Points Back side...

Страница 43: ...T C 8 L1 L2 Choke loop A 5 2 H m 5 9 K1 G8P 1A4TP12VDC 30A 10 K2 OJE SS 112HMF 10A 11 K3 K4 K6 JZC 32F 012 H 5A 12 L Reactor A 4 1 H m 5 1 13 BD1 BD2 Converter 25A 600V D25XB60 14 BD3 Converter D3SBA6...

Страница 44: ...HALL 6 FAN MOTOR 7 4 Way Valve To be connected with 4 way Valve YV 8 9 Power Source L line 10 Connect to Earth 11 PowerSource N line 12 1 Connect to one terminal of Inductor Whilt 13 PFC Connect to C2...

Страница 45: ...3 Key Testing Point Test Test2 Test3 Test4 Test5 Test6 Test7 Tset8 Test9 GND Test10 C A B D E F G H I J K L M Test11 N O P Q R Test16 Test12 Test13 Test14 Test15 S T...

Страница 46: ...t6 Capacitor C56 terminal Capacitor C56 12V 13VDC Test7 Capacitor C58 terminal C D V 5 8 5 C Test8 Capacitor C83 terminal C D V 3 3 3 8 C Test9 Capacitor C80 terminal C D V 8 1 5 1 0 8 C Test10 Betwee...

Страница 47: ...PCB of Outdoor Unit Front Side PCB of Outdoor Unit Back Side...

Страница 48: ...r Therefore if the power supply is turned off charge charging voltage DC280V to 380V remains and discharging takes a lot of time After turning off the power source if touching the charging section bef...

Страница 49: ...EOLQN RQFH V 2II EOLQN WZLFH V 2II EOLQN IRXU WLPHV FRROLQJ GHKXPLGLI LQJ H FHSW WKH LQGRRU IDQ PRWRU LV UXQQLQJ RWKHUV ZLOO VWRS WR UXQ KHDWLQJ DOO VWRS UXQQLQJ FRROLQJ GHKXPLGLI LQJ FRPSUHVVRU RXWG...

Страница 50: ...O ZRUN HDW DOO ZLOO VWRS RROLQJ GHKXPLGLI LQJ FRPSUHVVRU ZLOO VWRS LQGRRU IDQ PRWRU ZLOO ZRUN HDW DOO ZLOO VWRS RROLQJ GHKXPLGLI LQJ DIWHU UXQQLQJ IRU PLQV ODWHU WKH FRPSUHVVRU ZLOO VWRS WR UXQ LQGRRU...

Страница 51: ...running Cooling dehumidifying compressor stops running indoor fan motor works Heating all will stop running Overload normal works compressor running frequency declines Cooling dehumidifying compresso...

Страница 52: ...WLPHV 3RZHU YROWDJH LV QRW VWDDEOH 5HSODFH WKH RXWGRRU FRQWURO ERDUG 3 QGRRU XQLW DLU UHWXUQ LV SRRU RU IDQ VSHHG LV WRR ORZ 40 L3 DQ PRGXOH SURWHFWLRQ RROLQJ RXWGRRU IDQ PRWRU FRPSUHVVRU VWRS UXQQLQJ...

Страница 53: ...lt with the voltage testing circuit on control panel AP1 Replace the control panel AP1 Measure the AC voltage between terminal L and N on wiring board XT power supply Voltage within 210VAC 250VAC Shut...

Страница 54: ...in correct order If the voltage input of the machine is within normal range Use AC voltmeter to measure the voltage between terminal L and N on the wiring board XT If the compressor coil resistance is...

Страница 55: ...agram Then Restart the unit Remove the wires on the two ends of capacitor C2 Then use capacitance meter to measure the capacitor C2 Verify as per the Parameters Sheet Stop the unit and disconnect the...

Страница 56: ...outdoor ambient temperature higher than 53 20 minutes after the complete unit is powered off Is heat dissipation of the indoor unit and outdoor unit abnormal Normal protection please operate it after...

Страница 57: ...AP1 for outdoor unit control board Power on the unit Is stop time of the compressor longer than 3 minutes Restart it up after 3 minutes Does startup fail Are the wires for the compressor connected co...

Страница 58: ...nnected correctly Is connection sequence right Is the connection made in clockwise direction Connect the wires correctly Replace the control panel AP1 If the fault is eliminated Replace the compressor...

Страница 59: ...inutes after the complete unit is powered off Is the terminal FA for the PMV connected correctly Connect the wires correctly Resistances between the first four pins close to the terminal hole and the...

Страница 60: ...r short circuit Replace it as per the wiring diagram and reconnect the wires If the fault is eliminated Remove the PFC capacitor and measure resistance between the two terminals Is the resistance arou...

Страница 61: ...rmally before the failure occurs The AP1 voltage detection circuit is at fault Check wiring inside of the indoor and outdoor units Are wires broken Check the communication circuit of the outdoor unit...

Страница 62: ...ing Measure voltage at the Test 15 position as shown in the diagram with a voltmeter Value jumping Measure voltage at the Test 11 position as shown in the diagram with a voltmeter Value jumping Measur...

Страница 63: ...N N N N Temp Resistance Temp Temp Resistance Temp Resistance Resistance Appendix 1 form for indoor outdoor unit s ambient sensor numerical value of resistance...

Страница 64: ...N N N N Temp Resistance Temp Temp Temp Resistance Resistance Resistance Appendix 2 form for indoor outdoor unit s tube temperature sensor numerical value of resistance...

Страница 65: ...N N N N Temp Resistance Temp Temp Temp Resistance Resistance Resistance Appendix 3 form for indoor outdoor unit s air exhaust temperature sensor numerical value of resistance...