7
7
CAUTION: This heater creates warm air currents.
These currents move heat to wall surfaces next to
heater. Installing heater next to vinyl or cloth wall
coverings or operating heater where impurities (such
as, but not limited to, tobacco smoke, aromatic
candles, cleaning fluids, oil or kerosene lamps, etc.)
in the air exist, may discolor walls or cause odors.
CHECK GAS TYPE
Use only natural gas. If your gas supply is not natural gas, do not
install heater. Call dealer where you bought heater for proper
type heater.
IMPORTANT:
Vent-free heaters add moisture to the air. Although
this is beneficial, installing heater in rooms without enough venti-
lation air may cause mildew to form from too much moisture. See
Air for Combustion and Ventilation, pages 4 through 6.
CLEARANCES TO COMBUSTIBLES
(Vent-Free Operation Only)
WARNING: Maintain the minimum clearances. If
you can, provide greater clearances from floor, ceil-
ing, and adjoining side and back walls.
Carefully follow the instructions below. This stove is a freestanding
unit designed to set directly on the floor.
IMPORTANT:
You must
maintain minimum wall and ceiling clearances during installation.
The minimum clearances are shown in Figure 4. Measure from
outermost point of stove top.
Minimum Wall and Ceiling Clearances (see Figure 4)
A. Clearances from outermost point of stove top to any combus-
tible side wall should not be less than 12 inches.
B. Clearances from outermost point of stove top to any combus-
tible back wall should not be less than 6 inches (Includes Cor-
ner Installations).
C. Clearances from the stove top to the ceiling should not be less
than 48 inches.
INSTALLATION
Continued
Figure 4 - Minimum Clearance to Walls and Ceiling (Stove May
Vary Depending on Model)
Front View
Top View
Side View
Front of
Stove Unit
12"
Minimum
12"
Minimum
48"
Minimum
Ceiling
Side Wall
Side Wall
Back Wall
Side Wall
Side Wall
12
"
Minimum
12
"
Minimum
6
"
Minimum
6"
Minimum
48"
Minimum
Ceiling
Floor
Back Wall
Corner
Wall
Wall
6
"
Minimum
6
"
Minimum
Front of
Stove Unit
Front of
Stove Unit
INSTALLATION
Check Gas Type
Clearances to Combustibles