![Comfort Glow GSD2211 Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/comfort-glow/gsd2211/gsd2211_manual_2641330006.webp)
6
UNPACKING
1. Remove heater cabinet and hood from carton. Log is wrapped and inside heater.
Do not remove at this time.
2. Remove all protective packaging applied to heater for shipment.
3. Make sure your heater includes one hardware packet.
4. Check heater for any shipping damage. If damaged, call our Technical Service Department at
1-814-643-1775. Please do not return it to the store.
SAFETY PILOT
This heater has a pilot with an Oxygen Depletion Sensing (ODS) safety shutoff system.
The ODS/pilot shuts off the heater if there is not enough fresh air and cuts off main burner gas in the
event of flame out.
ELECTRIC PUSH BUTTON IGNITION SYSTEM
This heater is equipped with an electronic push button control system. This system requires
one AAA battery (provided).
THERMOSTAT HEAT CONTROL
The control automatically cycles the burner on and off to maintain a desired room
temperature.
DUAL FUEL CAPABILITY
Your heater is equipped to operate on either propane or natural gas. The heater is
shipped from the factory ready for connecting to propane. The heater can easily be
changed to natural gas by having your qualified installer follow the instructions on page
14 and the markings on the heater.
BLOWER KIT (OPTIONAL)
The blower kit helps to distribute the warmed air into the space more rapidly.
State of Massachusetts:
The installation must be made by a licensed plumber or gas fitter in
the Commonwealth of Massachusetts. Sellers of unvented propane or natural gas-fired
supplemental room heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale
of the unit.
In the State of Massachusetts, unvented propane or natural gas-fired space heaters shall
be prohibited in bedrooms and bathrooms.
In the State of Massachusetts the gas cock must be a T-handle type. The State of
Massachusetts requires that a flexible appliance connector cannot exceed three feet
in length.
LOCAL CODES
Install and use heater with care. Follow all codes. In the absence of local codes, use the latest edi-
tion of The National Fuel Gas Code, ANSI Z223.1, also known as NFPA 54*.
*Available from:
American National Standard Institute, Inc.
National Fire Protection Association, Inc.
1430 Broadway
1 Batterymarch Park
New York, NY 10018
Quincy, MA 02269-9101
This heater is designed for vent-free operation. State and local codes in some areas prohibit the use
of vent-free heaters.
PRODUCT FEATURES