INSTALLATION

CONNECTING TO GAS SUPPLY

 WARNING

: A qualified service technician must connect heater to gas supply. Follow all local  

codes. 

 CAUTION:

 Never connect heater directly to the gas supply. This heater requires an external

regulator (not supplied). The external regulator between the gas supply and heater must be installed. 
Gas supplier provides external regulator for natural gas. 

 WARNING

: Never connect heater to private (non-utility) gas wells. This gas is commonly known  

as wellhead gas.
The installer must supply an external regulator for liquid propane. The external regulator is
provided by the gas supplier for natural gas. The external regulator will reduce incoming gas pres-
sure. You must reduce incoming gas pressure to between 11 and 14 in. of water column for propane 
and between 6 and 14 in. of water column for natural gas. If you do not reduce incoming gas pres-
sure, heater regulator damage could occur. Install external regulator with the vent pointing down as 
shown in Fig. 9. Pointing the vent down protects it from freezing rain or sleet.

* Purchase the optional equipment shutoff valve from your local Home Center store.

 CAUTION

: Use only new black iron or steel pipe. Internally tinned copper tubing

 

may be used in certain areas. Check your local codes. Use pipe of ½ in. diameter

 

or greater to allow proper volume gas to heater. If pipe is too small, loss of pressure

 

will occur. Installation must include an equipment shutoff valve, union, and plugged

 

1/8-in. NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must

 

be upstream from heater (See Fig. 10).

IMPORTANT

: Install equipment shutoff valve in an accessible location. The equipment

shutoff valve is for turning on or shutting off the gas to the appliance. Apply pipe joint
sealant lightly to male threads. This will prevent excess sealant from going into pipe.
Excess sealant in pipe could result in clogged heater valves.

Approved

Flexible

Gas Line

or 1/2''

Black Pipe

Fig. 9 - Regulator Conversion

Fig. 10 - Gas Connection

(11"

(6"

14"

14"

Содержание GSD2211

Страница 1: ...ed by a qualified installer service agency or the gas supplier This is an unvented gas fired heater It uses air oxygen from the room in which it is installed Provisions for adequate combustion and ven...

Страница 2: ...re and Maintenance 21 Troubleshooting 23 Replacement Parts 26 Accessories 27 Warranty 29 SERVICE HINTS When Gas Pressure Is Too Low pilot will not stay lit burners will have delayed ignition heater wi...

Страница 3: ...o the gas The odor helps you detect a gas leak However the odor added to the gas can fade Gas may be present even though no odor exists Make certain you read and under stand all warnings Keep this man...

Страница 4: ...rly This heater has an Oxygen Depletion Sensing ODS safety shutoff system The ODS shuts down the heater if not enough fresh air is available See Air for Combustion and Ventilation page 8 If heater kee...

Страница 5: ...5 PRODUCT IDENTIFICATION Stove Cabinet Hood Screen Logs Ignitor Button Control Knob Stove Cabinet Hood Screen Logs Control Cover...

Страница 6: ...gas by having your qualified installer follow the instructions on page 14 and the markings on the heater BLOWER KIT OPTIONAL The blower kit helps to distribute the warmed air into the space more rapi...

Страница 7: ...onfined space This heater shall not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air Adjoining rooms are conn...

Страница 8: ...TU hr Example Gas heater logs __________BTU hr Gas water heater 30 000 BTU hr Other gas appliances ____BTU hr Vent free heater 26 000 BTU hr Total ____BTU hr Total 56 000 BTU hr Do not include direct...

Страница 9: ...spaces open to the outdoors These spaces include attics and crawl spaces Follow the National Fuel Gas Code NFPA 54 ANS Z223 1 Air for Combustion and Ventilation for required size of ventilation grill...

Страница 10: ...oor ceiling and adjoining wall than required CAUTION This heater creates warm air currents These currents move heat to wall surfaces next to heater Installing heater next to vinyl or cloth wall coveri...

Страница 11: ...panel extending the full width and depth of the appliance An optional blower kit is available from your retailer See Accessories page 27 If planning to use blower follow instructions provided with bl...

Страница 12: ...en routing the power cord be sure that the cord does not come into contact with any hot surface Operating Voltage is 110 to 120 VAC at 60 Cycle IMPORTANT Ensure the blower and gasket are oriented corr...

Страница 13: ...3 4 to install the other three 3 legs 6 With assistance lift the stove off of the padded surface and set upright onto the newly installed legs Nut Threaded Studs Figure 0 1 BATTERY INSTALLATION Step 1...

Страница 14: ...s Proceed to installing the gas line as instructed in the Owner s Manual Convert to natural gas Step 1 Remove access panel WARNING This appliance can be used with propane or natural gas It is shipped...

Страница 15: ...age could occur Install external regulator with the vent pointing down as shown in Fig 9 Pointing the vent down protects it from freezing rain or sleet Purchase the optional equipment shutoff valve fr...

Страница 16: ...alve 3 Check all connections for gas leaks NOTICE Most building codes do not permit concealed gas connections Check your local building code prior to using a Flexible Gas Line for this installation CA...

Страница 17: ...lames contacting logs will create soot It is very important to install the logs exactly as instructed Do not modify logs Use only logs supplied with heater Each log is marked with a number this number...

Страница 18: ...o gas supply Check reconnected fittings for leaks Test Pressures Equal To or Less Than 1 2 PSIG 3 5 kPa 1 Close equipment shutoff valve See Fig 12 2 Pressure supply piping system by either using compr...

Страница 19: ...ch has been under water E Any safety screen or guard removed for servicing an appliance must be replaced prior to operating the heater LIGHTING INSTRUCTIONS 1 STOP Read the safety information as noted...

Страница 20: ...to Appliance page 20 see Troubleshooting page 23 25 Note The pilot flame on natural gas units will have a slight curve but flame should be blue and have no yellow or orange color WARNING If yellow ti...

Страница 21: ...pected yearly by a qualified service person We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt To clean these parts we recommend using compressed air no...

Страница 22: ...gain Remove any large particles of dust dirt lint or pet hair with a soft cloth or vacuum cleaner nozzle 5 Blow air into the primary air holes on the orifice holder 6 In case any large clumps of dust...

Страница 23: ...able 6 Bad push button ignitor 7 Bad Battery 1 Replace electrode 2 Replace electrode 3 Replace ignitor cable 4 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 5 Replace ign...

Страница 24: ...s clogged 1 Contact your gas supplier 2 Clean burner see Care and Mainte nance page 21 22 or contact customer service Burner backfiring during combustion 1 Burner orifice is clogged or damaged 2 Burne...

Страница 25: ...Clean ODS pilot see Care and Maintenance page 21 22 Gas odor exists even when control knob is in OFF posi tion 1 Gas leak See Warning Statement at top of page 23 2 Control valve is defective 1 Locate...