Comfort Glow GSD2211 Скачать руководство пользователя страница 23

23

TROUBLESHOOTING

 WARNING: 

If you smell gas:

 

• Shut off gas supply.

 

• Do not try to light any appliance.

 

• Do not touch any electrical switch; do not use any phone in your building.

 

• Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

  • If you cannot reach your gas supplier, call the fire department.

IMPORTANT:

 Operating heater where impurities in air exist may create odors. Cleaning supplies, paint, paint 

remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix 
with combustion air and create odors. 
 

WARNING: 

Make sure that power is turned off before proceeding. 

 WARNING:

 Turn off and let cool before servicing. Only a qualified service person should service 

 

and repair heater. 

 

CAUTION:

 Never use a wire, needle, or similar object to clean ODS/pilot. This can damage ODS/ pilot unit.

PROBLEM 

POSSIBLE CAUSE 

CORRECTIVE ACTION

When ignitor button 
is pressed in, there 
is no spark at ODS/
pilot.

1. Ignitor electrode is 
  positioned wrong.
2. Ignitor electrode is broken.
3. Ignitor electrode is not 
  connected to ignitor cable.
4. Ignitor cable is pinched or 

wet.

5. Damaged ignitor cable.
6. Bad push button ignitor.
7. Bad Battery

1. Replace electrode.

2. Replace electrode.
3. Replace ignitor cable.

4. Free ignitor cable if pinched by any 

metal or tubing. Keep ignitor cable dry.

5. Replace ignitor cable.
6. Replace push button ignitor.
7. Check Battery and replace if needed.

When ignitor button
is pressed in, there
is a spark at ODS/
pilot but no ignition.

1. Gas supply is turned off or
  equipment shutoff valve is
 closed.
2. Control knob not fully
  pressed in while pressing
  ignitor button.
3. Air in gas lines when 
 installed.
4. ODS / pilot is clogged.
5. Gas regulator setting is not 

correct.

6. Control knob not in PILOT 

position.

7. Depleted gas supply (propane).

1. Turn on gas supply or open equipment 

shutoff valve.

2. Fully press in control knob while
  pressing ignitor button.
3. Continue holding down control knob. 
  Repeat igniting operation until air is 
 removed.
4. Clean ODS/pilot (see Care and 
  Maintenance, page 21-22) or replace 
  ODS/pilot assembly.
5. Replace gas regulator.
6. Turn control knob to PILOT position.
7. Contact local propane/LP gas company.

SERVICE HINTS
When Gas Pressure Is Too Low

• pilot will not stay lit
• burners will have delayed ignition

• heater will not produce specified heat

• for propane/LP units, propane/LP gas supply may be low
You may feel your gas pressure is too low. If so, contact your local natural or propane/LP gas supplier.

Содержание GSD2211

Страница 1: ...ed by a qualified installer service agency or the gas supplier This is an unvented gas fired heater It uses air oxygen from the room in which it is installed Provisions for adequate combustion and ven...

Страница 2: ...re and Maintenance 21 Troubleshooting 23 Replacement Parts 26 Accessories 27 Warranty 29 SERVICE HINTS When Gas Pressure Is Too Low pilot will not stay lit burners will have delayed ignition heater wi...

Страница 3: ...o the gas The odor helps you detect a gas leak However the odor added to the gas can fade Gas may be present even though no odor exists Make certain you read and under stand all warnings Keep this man...

Страница 4: ...rly This heater has an Oxygen Depletion Sensing ODS safety shutoff system The ODS shuts down the heater if not enough fresh air is available See Air for Combustion and Ventilation page 8 If heater kee...

Страница 5: ...5 PRODUCT IDENTIFICATION Stove Cabinet Hood Screen Logs Ignitor Button Control Knob Stove Cabinet Hood Screen Logs Control Cover...

Страница 6: ...gas by having your qualified installer follow the instructions on page 14 and the markings on the heater BLOWER KIT OPTIONAL The blower kit helps to distribute the warmed air into the space more rapi...

Страница 7: ...onfined space This heater shall not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air Adjoining rooms are conn...

Страница 8: ...TU hr Example Gas heater logs __________BTU hr Gas water heater 30 000 BTU hr Other gas appliances ____BTU hr Vent free heater 26 000 BTU hr Total ____BTU hr Total 56 000 BTU hr Do not include direct...

Страница 9: ...spaces open to the outdoors These spaces include attics and crawl spaces Follow the National Fuel Gas Code NFPA 54 ANS Z223 1 Air for Combustion and Ventilation for required size of ventilation grill...

Страница 10: ...oor ceiling and adjoining wall than required CAUTION This heater creates warm air currents These currents move heat to wall surfaces next to heater Installing heater next to vinyl or cloth wall coveri...

Страница 11: ...panel extending the full width and depth of the appliance An optional blower kit is available from your retailer See Accessories page 27 If planning to use blower follow instructions provided with bl...

Страница 12: ...en routing the power cord be sure that the cord does not come into contact with any hot surface Operating Voltage is 110 to 120 VAC at 60 Cycle IMPORTANT Ensure the blower and gasket are oriented corr...

Страница 13: ...3 4 to install the other three 3 legs 6 With assistance lift the stove off of the padded surface and set upright onto the newly installed legs Nut Threaded Studs Figure 0 1 BATTERY INSTALLATION Step 1...

Страница 14: ...s Proceed to installing the gas line as instructed in the Owner s Manual Convert to natural gas Step 1 Remove access panel WARNING This appliance can be used with propane or natural gas It is shipped...

Страница 15: ...age could occur Install external regulator with the vent pointing down as shown in Fig 9 Pointing the vent down protects it from freezing rain or sleet Purchase the optional equipment shutoff valve fr...

Страница 16: ...alve 3 Check all connections for gas leaks NOTICE Most building codes do not permit concealed gas connections Check your local building code prior to using a Flexible Gas Line for this installation CA...

Страница 17: ...lames contacting logs will create soot It is very important to install the logs exactly as instructed Do not modify logs Use only logs supplied with heater Each log is marked with a number this number...

Страница 18: ...o gas supply Check reconnected fittings for leaks Test Pressures Equal To or Less Than 1 2 PSIG 3 5 kPa 1 Close equipment shutoff valve See Fig 12 2 Pressure supply piping system by either using compr...

Страница 19: ...ch has been under water E Any safety screen or guard removed for servicing an appliance must be replaced prior to operating the heater LIGHTING INSTRUCTIONS 1 STOP Read the safety information as noted...

Страница 20: ...to Appliance page 20 see Troubleshooting page 23 25 Note The pilot flame on natural gas units will have a slight curve but flame should be blue and have no yellow or orange color WARNING If yellow ti...

Страница 21: ...pected yearly by a qualified service person We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt To clean these parts we recommend using compressed air no...

Страница 22: ...gain Remove any large particles of dust dirt lint or pet hair with a soft cloth or vacuum cleaner nozzle 5 Blow air into the primary air holes on the orifice holder 6 In case any large clumps of dust...

Страница 23: ...able 6 Bad push button ignitor 7 Bad Battery 1 Replace electrode 2 Replace electrode 3 Replace ignitor cable 4 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 5 Replace ign...

Страница 24: ...s clogged 1 Contact your gas supplier 2 Clean burner see Care and Mainte nance page 21 22 or contact customer service Burner backfiring during combustion 1 Burner orifice is clogged or damaged 2 Burne...

Страница 25: ...Clean ODS pilot see Care and Maintenance page 21 22 Gas odor exists even when control knob is in OFF posi tion 1 Gas leak See Warning Statement at top of page 23 2 Control valve is defective 1 Locate...

Страница 26: ...ical Service Department at 1 814 643 1775 8 30 a m 4 30 p m CST Monday Friday 1 2 3 ITEM No DESCRIPTION QTY PART NUMBER GSD2211 Series GSD2846 Series 1 Screen Assembly 1 EXP A3007 EXP A3005A 2 Legs 4...

Страница 27: ...TION QTY PART NUMBER GSD2211 GSD2846 1 Log Set Complete 1 700 S1018 700 M1018 1 1 Log 1 1 700 S1018 01 700 M1018 01 1 2 Log 2 1 700 S1018 02 700 M1018 02 1 3 Log 3 1 700 S1018 03 700 M1018 03 1 4 Log...