21
101810
If pilot flame pattern is incorrect, as shown in Figure 20
• turn heater off (see To Turn Off Gas to Appliance, page 19)
• see Troubleshooting, pages 22 through 25
BURNER FLAME PATTERN
Figure 21 shows a correct burner flame pattern. Figure 22 shows an incorrect
burner flame pattern. The incorrect burner flame pattern shows yellow tipping of
the flame. It also shows the flame higher than 1/2 the glass panel height.
NOTICE
Do not mistake orange flames with yellow tipping. Dirt or other fine
particles enter the heater and burn causing brief patches of orange
flame.
If burner flame pattern is incorrect, as shown in Figure 22
• turn heater off (see To Turn Off Gas to Appliance, page 19)
• see Troubleshooting, pages 22 through 25
CORRECT FLAME PATTERN
AT HIGH POSITION
1/2 GLASS HEIGHT
1/2 GLASS HEIGHT
INCORRECT FLAME PATTERN
AT HIGH POSITION
Yellow
Tipping
INSPECTING
BURNER
Continued
WARNING ICON
G 001
WARNING
If yellow tipping occurs, your heater could produce increased
levels of carbon monoxide. If burner flame pattern shows yellow
tipping, follow instructions at bottom of this page.
Figure 22 - Incorrect Burner Flame Pattern
Figure 21 - Correct Burner Flame Pattern
Содержание CGP18TB
Страница 31: ...31 101810 NOTES...