  WARNING:  Seal  any  fresh 

air vents or ash clean-out doors 

located on floor or wall of fire

-

place. If not, drafting may cause 

pilot  outage  or  sooting.  Use  a 

heat-resistant  sealant.  Do  not 

seal chimney flue damper.

 WARNING: Never install the 

heater

•  in  a  bedroom  or  bathroom 

unless  installed  as  a  vented 

appliance, see page 12.

•  in a recreational vehicle

•  where  curtains,  furniture, 

clothing  or  other  flammable 

objects are less than 42" from 

front, top or sides of heater

•  in high traffic areas

•  in windy or drafty areas

 CAUTION: This heater cre-

ates  warm  air  currents.  These 

currents move heat to wall sur-

faces next to heater. Installing 

heater next to vinyl or cloth wall 

coverings  or  operating  heater 

where impurities (such as, but 

not limited to, tobacco smoke, 

aromatic candles, cleaning flu

-

ids, oil or kerosene lamps, etc.) in 

the air exist, may discolor walls 

or cause odors.

IMPORTANT:

 Vent-free heaters add moisture 

to the air. Although this is beneficial, installing 

heater  in  rooms  without  enough  ventilation 

air may cause mildew to form from too much 

moisture. See 

Air for Combustion and Ventila-

tion

, page 6.

INSTALLATION

NOTICE: This heater is intended 

for  use  as  supplemental  heat. 

Use this heater along with your 

primary heating system. Do not 

install  this  heater  as  your  pri

-

mary heat source. If you have a 

central heating system, you may 

run system’s circulating blower 

while using heater. This will help 

circulate the heat throughout the 

house. In the event of a power 

outage, you can use this heater 

as your primary heat source.

NOTICE:  State  or  local  codes 

may only allow operation of this 

appliance in a vented configura

-

tion. Check your state or local 

codes.

 WARNING: A qualified ser

-

vice person must install heater. 

Follow all local codes.

  WARNING:  Make  sure  the 

selector switch is in the OFF po

-

sition before installing heater. 

 WARNING: Before installing 

in a solid fuel burning fireplace, 

the  chimney  flue  and  firebox 

must be cleaned of soot, creo

-

sote, ashes and loose paint by a 

qualified chimney cleaner. Creo

-

sote will ignite if highly heated. 

A dirty chimney flue may create 

and  distribute  soot  within  the 

house. Inspect chimney flue for 

damage. If damaged, repair flue 

before operating heater.

Содержание CCL3924NRA

Страница 1: ...ycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a quali fi...

Страница 2: ...fired heat er It uses air oxygen from the room in which it is installed Provisions for adequate combustion and ventilation air must be provided Refer to Air for Combustion and Ven tilation section on...

Страница 3: ...ough no odor exists Make certain you read and understand all warnings Keep this manual for reference It is your guide to safe and proper operation of this heater WARNING Any change to this heater or i...

Страница 4: ...er is designed to be smoke less If logs ever appear to smoke turn off heater and call a qualified service person Note During initial operation slight smok ing may occur due to log curing and heater bu...

Страница 5: ...licensed plumber or gas fitter in the Commonwealth of Massachusetts Sellers of unvented propane or natural gas fired supplemental room heaters shall provide to each purchaser a copy of 527 CMR 30 upo...

Страница 6: ...anever Newmaterials increasedinsulationand new construction methods help reduce heat loss in homes Home owners weather strip and caulk around windows and doors to keep the cold air out and the warm ai...

Страница 7: ...g room is supplied with grills or openings add the volume of these rooms to the total volume of the space 2 Multiply the space volume by 20 to determine the maximum Btu Hr the space can support ______...

Страница 8: ...and Ventilation for required size of ventilation grills or ducts Ventilation Air From Outdoors Provide extra fresh air by using ventilation grills or ducts You must provide two perma nent openings on...

Страница 9: ...s without enough ventilation air may cause mildew to form from too much moisture See Air for Combustion and Ventila tion page 6 Installation NOTICE Thisheater isintended for use as supplemental heat U...

Страница 10: ...ble material must be 4 from the side of the fireplace opening see Figure 4 Note When installing your gas logs into a manufactured firebox follow firebox manufacturer s instructions for minimum clearan...

Страница 11: ...A6053 see Accessories page 31 Less than 8 Noncombustible material must be extended to at least 8 See Between 8 and 12 above If you can not extend material you must operate heater with flue damper open...

Страница 12: ...lace Clearances Above Combustible Flooring Figure 8 Minimum Fireplace Clearances If Installed at Floor Level INSTALLING DAMPER CLAMP AC CESSORY FOR VENTED OPERATION Note When used as a vented heater a...

Страница 13: ...e provided with heater approved flexible gas hose not provided if allowed by local codes sealant resistant to propane LP gas not provided electric drill with 3 16 masonry drill bit Note Install option...

Страница 14: ...y to male NPT threads This will prevent excess sealant from going into pipe Excess sealant in pipe could result in clogged heater valves Installation Continued Figure 13 External Regulator With Vent P...

Страница 15: ...or fittings CHECKING GAS CONNECTIONS WARNING Testallgaspiping and connections internal and external to unit for leaks after installing or servicing Correct all leaks at once WARNING Never use an open...

Страница 16: ...Closed Equipment Shutoff Valve Figure 16 Checking Gas Joints Propane LP Tank Equipment Shutoff Valve Control Valve Location Figure 17 Checking Gas Joints Gas Meter Equipment Shutoff Valve Control Valv...

Страница 17: ...ng It is very important to install these logs exactly as instructed Do not modify logs Only use logs supplied with heater 1 Place front log 1 on grate fingers Make sure front log rests firmly between...

Страница 18: ...ON Figure 21 Installing Crossover Log 4 CCL3930PR NRA Shown Log 2 Log 3 Pegs Figure 22 Installing Crossover Log 5 CCL3930PR NRA Shown AUTO OFF ON 7 Figure 24 Installing Crossover Log 7 to Models CCL39...

Страница 19: ...WARNING Burners will come on automatically within one minute when the selector switchisintheONpositionafter the pilot is lit FOR YOUR SAFETY READ BEFORE LIGHTING WARNING If you do not fol low these in...

Страница 20: ...light pilot The pilot is attached to the front burner If needed keep pressing ignitor button until pilot lights Note If pilot does not stay lit contact a qualified service person or gas supplier for...

Страница 21: ...here be tween HI and LO Slide the selector switch to the REMOTE position see Figure 27 Note The burner may light if hand held re mote was on when selector switch was last turned off You can now turn t...

Страница 22: ...Yourlocal computer store hardware store or home center may carry compressed air in a can If using com pressed air in a can please follow the directions on the can If you don t follow directions on th...

Страница 23: ...hen in stalled 5 Depleted gas supply pro pane LP only 6 ODS pilot is clogged 7 Gas regulator setting is not correct REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tub...

Страница 24: ...After ODS pilot lights keep control knob pressed in 30 seconds 3 Fully open equipment shut off valve 4 A Contact local natural or propane LP gas company B Clean ODS pilot see Cleaning and Maintenance...

Страница 25: ...on and Ventilation require ments page 6 1 Turn control knob to LO position and let warm up for a minute 2 Operate burner until air is removed from line Have gas line checked by local natural or propan...

Страница 26: ...ocate and correct all leaks see Checking Gas Con nections page 15 2 Replace control valve 1 Take apart gas tubing and remove foreign matter 2 Locate and correct all leaks see Checking Gas Con nections...

Страница 27: ...0NRA Rating Variable 20 000 39 000 Btu Hr Type Gas Natural Ignition Piezo Manifold Pressure 3 5 W C Inlet Gas Pressure in of water Max 10 5 W C Min 5 W C CCL3924PRA and CCL3930PRA Rating Variable 20 0...

Страница 28: ...27 18 23 12 11 14 4 5 1 2 17 10 21 20 22 6 7 3 9 20 16 8 15 29 28 28 25 26 O F F P I L O T O N H I L O O F F P I L O T O N H I L O 24 31 13 Parts MODELS CCL3924PRA CCL3924NRA CCL3930PRA and CCL3930NRA...

Страница 29: ...Pilot Tube 1 16 103781 02 103781 02 Gas Control Valve LP 1 103781 01 103781 01 Gas Control Valve NG 1 17 103345 01 103345 01 103345 01 103345 01 Lower Bracket 1 18 M11084 38 M11084 38 M11084 38 M1108...

Страница 30: ...elayed ignition heater will not produce specified heat propane LP gas supply may be low You may feel your gas pressure is too low If so contact your local propane LP gas supplier If this product is mi...

Страница 31: ...FMI PRODUCTS LLC at 1 866 328 4538 for information You can also write to the address listed on the back page of this manual RECEIVER AND HAND HELD THERMOSTAT REMOTE CONTROL KIT MLCR M For all Remote...

Страница 32: ...product and or FMI PRODUCTS LLC who will provide original factory replacement parts Failure to use original factory replacement parts voids this warranty Travel handling transportation diagnostic mat...

Отзывы: