background image

Owner’s Manual  -  

PTTC/PTTE/PTTH-09/12B-1

7

IMPORTANTNOTETOTHEOWNER

This equipment is to be serviced by professionally trained

personnel only. If this equipment is improperly installed,

adjusted or altered by an unqualified person, a safety

hazard may result.

IMPORTANT NOTE TO THE SERVICER

Read this manual and familiarize yourself with the specific

items which must be adhered to before attempting to

service this unit. The precautions listed in this manual

should not supersede existing practices but should be

considered as supplemental information.

TRANSPORTATION DAMAGE 

All units are securely packed in shipping containers ap-

n

o

tr

a

c

e

h

T

.

n

o

it

a

i

c

o

s

s

A

ti

s

n

a

r

T

e

f

a

S

l

a

n

o

it

a

N

e

h

t

y

b

d

e

v

o

r

p

should be checked upon arrival for external damage. If

damage is found, immediately make a written request for

inspection by the carrier’s agent.
In the event of damage:

1. Note on the delivery receipt any visible damage to

shipment or container.

2. Notify carrier promptly and request an inspection.
3. File the claim with the following supporting documents

within the six month statute of limitations.

a. Original Bill of Lading, certified copy, or indemnity

bond.

b. Original paid freight bill or indemnity.
c. Original invoice or certified copy, showing trade and

other discounts or reductions.

d. Copy of the inspection report issued by carrier’s

representative at the time damage is reported to the

carrier.

The carrier is responsible for making prompt inspection of

e

h

T

.

m

i

a

l

c

h

c

a

e

f

o

n

o

it

a

g

it

s

e

v

n

i

h

g

u

o

r

o

h

t

a

r

o

f

d

n

a

e

g

a

m

a

d

distributor or manufacturer will not accept claims from

dealers for transportation damage.

UNPACKING THE UNIT

1. Cut the carton banding and open the carton.
2. Remove the literature, hardware pack, upper styrofoam

shipping blocks, and styrofoam corner posts.

3. Remove the front assembly.
4. Lift the unit from the remaining carton.
5. Dispose of the cardboard and styrofoam at an approved

Recycle Center. Check all contents for damaged or

missing parts. In case of concealed damage, notify the

carrier as soon as possible—preferably within 5 days.

Refer to step 3 of the Transportation Damage section if

damage or missing parts are noted.

OPERATING  INSTRUCTIONS

Check the data specification plate and ensure the proper 

voltage and current rating for the type of power plug on the 

unit is available.  DO NOT REMOVE THE GROUNDING 

PRONG FROM THE POWER CORD..         See Figure 1 for the 

types of acceptable plugs. Do not use an extension cord 

for the installation of this product. Refer to the data 

specification plate for electrical requirements.

13 amp

Figure 1

• LCDI or AFCI Power Cords - Underwrites Laboratories

and the National Electric Code (NEC) now require

power cords that sense current leakage and can open

the electrical circuit to the unit on units rated at 250

volts or less.  In the event that unit does not operate,

check the reset button located on or near the head of

the power cord as part of the normal troubleshooting

procedure

Note:

 

Plug may be different than the actual product. Please 

refer to actual product.

.

LCDI Power Cord

VOLTAGE MEASUREMENTS
Before connecting the unit, measure the supply voltage.

Voltage must fall within the voltage utilization range given

in Table 1.

Operating Voltage

Unit Voltage

Rating

Voltage Utilization Range

Minimum

Maximum

230/208

187

253

115

103

126

Table 1

Operating Voltage

120V

240V

240V

18 amp

15 amp

-4-

RESET

TEST

Содержание Century PTTC09B-1

Страница 1: ...www marsdelivers com Owner s Manual Room Air Conditioner Cool Only PTTC09B 1 PTTC12B 1 Cool w Elect Heat PTTE09B 1 PTTE12B 1 Heat Pump PTTH09B 1 PTTH12B 1 ...

Страница 2: ...f common sense a matter of thinking before acting Most dealers have a list of specific good safety practices follow them The precautions listed in this Installation Manual areintendedassupplementaltoexistingpractices However ifthereisadirectconflictbetweenexisting practices and the content of this manual the precautions listed here take precedence RECOGNIZE THIS SYMBOL AS A SAFETY PRECAUTION WARNI...

Страница 3: ...y Indicates a hazardous situation that if not avoided could result in death or serious injury Indicates a hazardous situation that if not avoided may result in minor or moderate injury Indicates important but not hazard related information used to indicate risk of property damage Indicates a hazard that would be assigned a signal word WARNING or CAUTION ...

Страница 4: ...ectric parts Do not use the socket if it is loose or damaged Do not use the power cord close to heating appliances Always install circuit breaker and a dedicated power circuit Do not open the unit during operation Do not use the power cord near flammable gas or combustibles such as gasoline benzene thinner etc ƽ It may cause fire ƽ It may cause fire and electric shock ƽ It may cause an explosion o...

Страница 5: ...the power cord is not compressed Turn off the main power switch when not using the unit for a long time Always insert the filters securely Clean the filter once every two weeks Do not drink water drained from air conditioner Appearance may be deteriorated due to change of product color or scratching of its surface There is danger of fire or electric shock It contains contaminants and could make yo...

Страница 6: ...he power supply cord is now supplying electricity to the unit On some products this is also indicated by a light on the plug head Operation of Current Device Please contact Customer Service with a new cord please contact Customer Service NOTICE 3 ...

Страница 7: ... will not accept claims from dealers for transportation damage UNPACKING THE UNIT 1 Cut the carton banding and open the carton 2 Remove the literature hardware pack upper styrofoam shipping blocks and styrofoam corner posts 3 Remove the front assembly 4 Lift the unit from the remaining carton 5 Dispose of the cardboard and styrofoam at an approved Recycle Center Check all contents for damaged or m...

Страница 8: ...e for a complete description of the installation proce dure NOTE Wallsleeveisnotshippedwithchassis and must be purchased separately Wall Sleeve Outside Wall Outside Inside Level 1 4 Bubble Tilt To Outside Figure 2 CHASSIS INSTALLATION 1 Remove front grille See Figure A Lift up on Filter Handle Figure A The front grille can be removed for more thorough cleaning or to make the model and serial numbe...

Страница 9: ... chassis into the sleeve Ensure that the ground wire is not pinched or in the path of the condenser fan Loosen locking plate screw and rotate tab with tab behind wall case flange See Figure C then tighten locking plate screw Locking Plate Figure C 6 If outlet is on the left side of the unit route power cord as shown in Figure D Power Cord Clamp Figure D MOUNTING SCREW GRDUND WIRE ...

Страница 10: ...om will be circulated and condit ioned When set at OPEN some inside air is exhausted outside Locating Locating Hole Hole Screw Hole Screw Hole OPEN position CLOSE position Mesh end toward back Mesh end toward front Figure E To open or close the vent 1 Remove the front grille 2 Remove the vent card screw 3 Remove the vent card turn it over and replace it by locating rear hole in card over locating ...

Страница 11: ...onal injury or death do not service this unit without first opening all disconnects and or removing the unit cord set plug from the wall outlet WARNING To avoid the risk of electrical shock personal injury or property damage do not use an extension cord with this unit WARNING To avoid the risk of fire property damage or personal injury use only copper conductors WARNING To avoid the risk of person...

Страница 12: ...URE OR TIME RAISES TEMPERATURE OR TIME SETS FAN SPEED SETS MODE RESET FILTER DISPLAYS TEMPERATURE TIME TURNS UNIT ON OR OFF AIR CONDITIONER FEATURES ON OFF button MODE button button FAN button SWING button SLEEP button TIMER button Timer on Timer off Sending signal swing operation sleep operation lock set speed Set time Set temperature heat operation fan operation dry operation cool operation auto...

Страница 13: ... Pressing or button once will increase or decrease set temperature by 1 F C Hold or button for 2s set temperature on remote controller will change quickly Release the button after your required set temperature is reached When setting Timer On or Timer Off press or button to adjust the time See TIMER Button for setting details When selecting auto mode air conditioner will operate automatically acco...

Страница 14: ...t the time for Timer Off Pressing or button once will increase or decrease the time by 0 5h Hold or button for 2s time will change quickly Release the button after your required set time is reached Then press TIMER button to confirm it T OFF and H icon will stop blinking When unit is off press this button to set Timer On T ON and H icon will be blinking Within 5s press or button to adjust the time...

Страница 15: ...fan blowing angle Replacement of batteries in remote controller reinstall remove battery cover of battery box 1 Press the back side of remote controller on the spot marked with and then push out the cover of battery box along the arrow direction 2 Replace two No 7 AAA 1 5V dry batteries and make sure the positions of and polar are correct 3 Reinstall the cover of battery box NOTICE During operatio...

Страница 16: ...WN it allows the indoor fan to cycle on off with the compressor When this switch is disabled UP it allows the indoor fan to run continuously The default setting is DOWN fan cycle Fan Cycle Continuous Heat When this switch is enabled DOWN it allows the indoor fan to cycle on off with the heater or the compressor operation When this switch is disabled UP it allows the indoor fan to run continuously ...

Страница 17: ...utomatically decrease Auto fan speed cannot be used when in the Fan Only mode AIR CONDITIONER FEATURES Set Off Filter Reset On Timer Temp Timer Temp Timer Mode Speed Fan Cool Heat Fan Only Med High Low Auto Set Off Filter Reset On Timer Temp Timer Temp Timer Mode Speed Fan Cool Heat Fan Only Med High Low Auto Set Off Filter Reset On Timer Temp Timer Temp Timer Mode Speed Fan Cool Heat Fan Only Med...

Страница 18: ...to Timer mode for 5 seconds then Timer light on Set light off In Timer mode Unit keeps previously set temperature and fan speed Temperature display set temperature no display if power turn off Press Timer once LED display remaining time of set time LED returns to set temperature in 5 seconds When in Fan Only mode LED only displays room temperature not display set temperature Turning the unit ON or...

Страница 19: ...air If the air conditioner is off and is then turned on while set to a Cool setting or if turned from a fan setting to a Cool setting it may take approximately 3 minutes for the compressor to start and cooling to begin Set Off Filter Reset On Timer Temp Timer Temp Timer Mode Speed Fan Cool Heat Fan Only Med High Low Auto Set Off Filter Reset On Timer Temp Timer Temp Timer Mode Speed Fan Cool Heat ...

Страница 20: ... a sensor has failed Set Off Filter Reset On Timer Temp Timer Temp Timer Mode Speed Fan Cool Heat Fan Only Med High Low Auto Set Off Filter Reset On Timer Temp Timer Temp Timer Mode Speed Fan Cool Heat Fan Only Med High Low Auto Set Off Filter Reset On Timer Temp Timer Temp Timer Mode Speed Fan Cool Heat Fan Only Med High Low Auto Set Off Filter Reset On Timer Temp Timer Temp Timer Mode Speed Fan ...

Страница 21: ...rews that mount the condenser coil top cover to condenser shroud Normal Operating Sounds and Conditions POPPING OR GURGLING SOUNDS This sound is the refrigerant traveling through the lines This is a normal sound which may be heard for a few seconds after the unit shuts off WATER TRICKLING SOUNDS This sound is produced by the water as it is picked up and run over the coils This procedure improves t...

Страница 22: ...brown out conditions or circuit interruptions Air flow around any section of the unit has not been restricted DURATION OF WARRANTY REGISTRATION The warranty begins on the date of purchase by the original consumer The consumer must retain a receipted bill of sale as proof of warranty period Without this proof the express warranty begins on the date of shipment from the factory REMEDY PROVIDED BY TH...

Страница 23: ...Owner s Manual PTTC PTTE PTTH 09 12B 1 23 THIS PAGE INTENTIONALLY LEFT BLANK ...

Страница 24: ...GDWD RQ WKH DFWXDO SURGXFW SULRU WR EHJLQQLQJ DQ LQVWDOODWLRQ SUHSDUDWLRQV QFHQWLYH DQG UHEDWH SURJUDPV KDYH SUHFLVH UHTXLUHPHQWV DV WR SURGXFW SHUIRUPDQFH DQG FHUWLILFDWLRQ OO SURGXFWV PHHW DSSOLFDEOH UHJXODWLRQV LQ HIIHFW RQ GDWH RI PDQXIDFWXUH KRZHYHU FHUWLILFDWLRQV DUH QRW QHFHVVDULO JUDQWHG IRU WKH OLIH RI D SURGXFW 7KHUHIRUH LW LV WKH UHVSRQVLELOLW RI WKH DSSOLFDQW WR GHWHUPLQH ZKHWKHU D VSH...

Отзывы: