background image

IOM -

 

SELF-ACTING DIAPHRAGM VALVES 

MAXOMATIC VMXBERL24C 

©COMEV

AL

 V

A

L

VE SYSTEMS 

T

echnical Dept. Ref. IOM-SELF-ACTING DIAPHRAGM V

A

L

VES, MAXOMA

TIC VMXBXERL24C-Ed.15/05

Comeval V

alve Systems reserves the right to alter any technical data contained in this Manual without prior notice. Regularly u

pdated data on www

.comeval.es

4.2  Area of Application

These valves represent a simple, economical, reliable and easy to maintain on-line solution for hydraulic applications for 
open/close by Solenoid, as well as for control of pressure, fl ow, level, or combination thereof. Thus they are an excellent 
choice for applications with irrigation or industrial water, where it is not normally required a high response speed, high 
accuracy or low hysteresis, provided the fl uid and pressure and temperature conditions be compatible with the valve 
building materials.

4.3 Technical data – remarks

For data such as main features, duties/limits of use, dimensions, weights, etc. refer to Data Sheet.

4.4 Marking/nameplate

Nameplate description of the valve:

5. – INSTALLATION
5.1 General remarks on installation

The following points should be taken into account in addition to the general principles governing installation work:

     

ATTENTION!

- Remove fl ange covers or any other remaining packing/storage protection if present.
- The interior of the valve and the pipeline must be free of foreign particles.
- The valve is unidirectional. Follow the arrow in the cover for installation.
- Lay pipelines such that damaging transverse, bending and torsional forces are avoided.
- Protect valves from dirt during construction work.
- Protect the valve soft parts from heating caused by welding works at the plant during commissioning.
- Product parts such as pilot circuit must not be used to take up external forces that they are not designed for: e.g. 
do not use them as climbing aids, or as connecting points for lifting gear, etc.
- Suitable materials handling and lifting equipment should be used for assembly work. During assembly work, en-
sure that the valve is fi xed adequately. See data sheet for weights.
-The preferred installation position is in horizontal pipeline with cover upwards, or alternatively in vertical pipelines.
- You must only operate the unmounted valve while observing all the safety measures.

Page 3

Valve closed,                               Valve opening or closing,                                    Valve opened,

    activation chamber full                         activation chamber partially full     

 activation chamber empty

Mark

Description

Manufacturer logo

    www.comeval.es

Website of manufacturer

MAXOMATIC

Series name

VMXBXERL24C

Valve code

DN

Nominal diameter

Y.VV

Manufacturing year (Y.14 = 2014)

ZZZZZ-N

Batch / Serial no.

TS

Min. / Max. temperature

PS

Working Pressure

Содержание MAXOMATIC Series

Страница 1: ...OTES ON POSSIBLE DANGERS 2 2 1 Significance of symbols 2 2 2 Explanatory notes on safety information 2 3 0 PRESERVATION STORAGE AND TRANSPORT 2 4 0 DESCRIPTION 2 4 1 General Description Operating Principles 2 4 2 Area of Application 3 4 3 Technical data remarks 3 4 4 Marking nameplate 3 5 0 INSTALLATION 3 5 1 General remarks on installation 3 5 2 Assembling additional modules 4 5 3 Requirements at...

Страница 2: ...turn can cause serious injury to persons or damage to property 3 PRESERVATION STORAGE AND TRANSPORT ATTENTION Use proper packing for transportation Keep storage protection before installation The valve surface is protected by an epoxy paint In order to prevent damage corrosion or rust on the surface avoid ex treme temperatures keep at 5ºC to 50ºC avoid high environmental humidity or corrosive envi...

Страница 3: ... covers or any other remaining packing storage protection if present The interior of the valve and the pipeline must be free of foreign particles The valve is unidirectional Follow the arrow in the cover for installation Lay pipelines such that damaging transverse bending and torsional forces are avoided Protect valves from dirt during construction work Protect the valve soft parts from heating ca...

Страница 4: ...under operation in case hands are introduced inside the valve When the valve discharges to atmosphere we recommend to set an orifice plate downstream of the valve properly sized to control the flow rate and minimize cavitation This will also help to diaphragm opening and will ease foreign particles removal When using the valve as an end seal the employers liability insurance association of the gas...

Страница 5: ...gh velocities as refe rence max 4 m s or lower in case of abrasive media Prevent pulsing flow or water hammers which are very harmful for valves and the rest of the components Flooding of the product is not recommended Allow enough space for valve installation operation and maintenance It is recommended to install a proper sized mesh strainer upstream the valve in order to protect seating surfaces...

Страница 6: ...rd obstructions or blocking in the Pilot system Check the valve surface inside and outside and retouch coating protection when needed If advanced corrosion or ero sion is observed double check service and valve features and replace the valve properly In case of body cover leakage retighten the bolts in a crosswise moderate and uniform manner If leakage cannot be corrected dismount the cover clean ...

Страница 7: ...d inspect the body and diaphragm clean or replace parts Body seat wear Strainer or Pilot circuit clogged Check if the fluid reaches the activation chamber by unplugging the corresponding connection Revise filtering and Pilot circuit Solenoids calcified or with impurities Check the Solenoid core clean or replace if needed Valve is not regulating properly Pilot is not well adjusted Check tightening ...

Страница 8: ...ng from those laid down by specifications or other agreements Justified complaints will be eliminated by repair carried out by us or by a specialist appointed by us No claims will be accepted beyond the scope of this warranty The right to replacement delivery is excluded The warranty shall not cover maintenance work Our guarantee coverage does not cover for any commissioning maintenance or install...

Страница 9: ... 05 Comeval Valve Systems reserves the right to alter any technical data contained in this Manual without prior notice Regularly updated data on www comeval es 12 LAYOUT AND PARTS LIST Page 9 Nº PART 1 Body 2 Cover 3 Diaphragm 4 Bolts nuts 5 Valve 4 way 6 1 Solenoid 24Vdc 6 2 Solenoid latch 7 Pilot 8 Nameplate 9 Tubing 10 Inner strainer LAYOUT MAIN PARTS ...

Отзывы: