![Comet scout 135 classic Скачать руководство пользователя страница 29](http://html1.mh-extra.com/html/comet/scout-135-classic/scout-135-classic_instruction-manual_2640648029.webp)
29
to children playing.
9 PROBLEMS, CAUSES AND SOLUTIONS
WARNING
• Before undertaking any action, follow the instructions in the
“Switching off”
section. If it is not possible
to restore correct operation of the high pressure cleaner using the information in the table below, contact
a
Skilled Technician
.
PROBLEMS
CAUSES
SOLUTIONS
By setting the switch (2)
to “1”, the water cleaner
does not start.
Remember also what
mentioned in the note
of section “Interrupting
the use (Total Stop)”
A safety device of the system
to which the water cleaner is
connected (fuse, differential
switch, etc.) has triggered.
Reset the protection device.
In case of a new triggering, do not use
the water cleaner and apply to a Skilled
Technician.
The plug of the power supply
cable is not inserted correctly.
Disconnect the plug from the socket and
reconnect it correctly.
The water cleaner
vibrates a lot and is
noisy.
The water suction filter/
gasket (33) and/or the inner
water inlet filter is dirty.
Observe what mentioned in the section
“Routine maintenance” and “Special
maintenance”.
The water supply is not enough. Check that the tap is completely opened
and that the capacity of the hydraulic
network conforms with what mentioned
in the section “Features and technical
specifications”.
The water cleaner does
not reach the maximum
pressure.
The nozzle-holding head (18) is in
low pressure position (Fig. 1-a).
Rotate the nozzle-holding head as shown
in Fig. 1-b.
The water nozzle (20) is worn.
Replace the nozzle according to what
mentioned in the section “Features and
technical specifications”.
Poor detergent suction. The nozzle-holding head (18) is in
low pressure position (Fig. 1-b).
Rotate the nozzle-holding head as shown
in Fig. 1-a.
The used detergent is too viscous. Use a detergent that is recommended by
the producer,by observing the thinning
indicated on the label.
Product missing in the tank.
Add product to the tank.
No water comes out
from the nozzle (20).
Water missing.
Check that the tap of the water network is
completely opened.
Water nozzle clogged.
Clean and/or replace the nozzle according
to what mentioned in the section
“Features and technical specifications”.
The water cleaner stops
during the operation.
A safety device of the system
to which the water cleaner is
connected (fuse, differential
switch, etc.) has triggered.
Reset the protection device.
In case of a new triggering, do not use
the water cleaner and apply to a Skilled
Technician.
The amperometric protection
device has cut in.
Observe what mentioned in the section
“Safety devices”.
Rotating the main
switch (2), the motor
hums but does not start.
The electrical system and/or the
extension are not suitable.
Observe what mentioned in the section
“Checks and connection to mains
electricity supply”.
The water cleaner does
not supply hot water.
The Diesel in the tank is below
the minimum level.
Add Diesel
The Diesel filter is clogged.
Observe what mentioned in the section
“Special maintenance”.
EN
Содержание scout 135 classic
Страница 2: ......
Страница 4: ...1 ...
Страница 5: ...2 ...
Страница 188: ...NOTE ...
Страница 189: ...NOTE ...
Страница 190: ...NOTE ...
Страница 191: ......