be reached by the water cleaner: with these accessories it is therefore necessary to limit the temperature,
by operating on knob (27) in the due way.
It is possible to build in the standard equipment of the water cleaner with a rich range of accessories.
To buy them, apply to the dealer or to an authorised service centre.
3.3.1 o
ptional
acceSSorieS
with
max
.
operating
temperature
lower
than
90 °c/194 °f
• Pipe draining probe: maximum operating temperature 60 °C/140 °F.
• Rotating nozzle lance hose: maximum operating temperature 60 °C/140 °F (there is also a professional
version with maximum operating temperature of 100 °C/212 °F).
• Floor-washing lance: maximum operating temperature 60 °C/140 °F.
• Rotating water jet brush: maximum operating temperature 60 °C/140 °F.
4 INSTALLATION
See Fig. 2 at the front of these operating and maintenance instructions
4.1 a
ssEMblIng
thE
a
ccEssorIEs
a) Assemble the fixed fan-like jet professional nozzle (20) on the nozzle-holding head (18), by tightening
well with a 14-mm socket wrench (not supplied). Operation A of Fig. 2.
b) Screw the end of the high-pressure hose (7) (side without fast coupling for CLASSIC) on the water gun
thread (16) and tighten well with two open end 17-mm wrenches (not supplied). Operation B of Fig. 2.
c) Engage the lance hose (17) onto the water gun (16) and screw well. Operation G of Fig. 2.
d) Unwind the high-pressure hose (7), insert the fast-coupling connector (22) onto the water outlet
connector (6), screw and tighten the ring nut by hand (only CLASSIC). Operation C of Fig. 2.
e) Insert the water suction filter/gasket (33) into the water inlet connector (1), by paying attention to position
the projecting side of the filter inside the connector and screw well the water suction connector (35).
Operation D of Fig. 2
4.2 c
hEcks
and
c
onnEctIon
to
thE
M
aIns
W
atEr
s
upply
CAUTION
• The water supply must be able to guarantee the adequate delivery of water flow to the high pressure
cleaner; refer to the table of technical specifications.
In case of doubt, contact a Skilled Technician.
• Do not supply the water cleaner with water at a temperature in excess of 40°C/104°F or below 5°C/41°F.
• The pressure of the water supply must not be in excess of 8 bar/116 psi.
• Do not operate the high pressure cleaner with a priming depth in excess of 0 m/0 ft.
• Do not operate the high pressure cleaner if it is not connected to a water supply.
• Do not supply the high pressure cleaner with salt water or water containing impurities. In this event,
run the high pressure cleaner for a few minutes with clean water.
WARNING
• Follow current regulations for connection to the mains water supply in the country where the water cleaner
is installed.
4.3 c
hEcks
and
c
onnEctIon
to
thE
M
aIns
E
lEctrIcIty
s
upply
WARNING
• A
Skilled Technician
must check that the electrical supply complies with the data indicated on the
identification label (12) on the high pressure cleaner. It is especially important that the supply voltage does
not differ more than ± 5% from that indicated on the label.
• All connections to mains electricity must be carried out by a
Qualified Eletrician
according to IEC 364
regulations or the equivalent standard in the country where the high pressure cleaner is to be used. It is
especially important that the current outlet where the high pressure cleaner is connected is provided with
an earth conductor and a suitable fuse (according to the size indicated on the identification label and in the
table of technical specifications), and must be protected by a magneto-thermal differential circuit breaker,
whose sensitivity is not in excess of 30 mA.