Comet System T2314 Скачать руководство пользователя страница 4

 

  IE-SNC-T23(4)14-04 

Dimensions 

– T2314 

 
 
 
 
 
 

Transmitter with RS232 

 
 
 
 
 
 
 

Dimensions 

– T2414 

 
 
 
 
 
 

Transmitter with RS485 

 
 
 
 
 
 
 
 

Dimensions 

– T2314L, T2414L 

 
 
 
 
 
 
 
 

Connection:

 see Appendix B 

 

 
 
 

Содержание T2314

Страница 1: ...cturer reserves the right to make technical changes to the device without previous notice Misprints reserved Manufacturer is not responsible for damages caused by using the device in conflict with thi...

Страница 2: ...www cometsystem com It supports make the adjustment of the device too This procedure is described at file Calibration manual pdf which is installed commonly with the software Change of some parameter...

Страница 3: ...r side The cable should be led in one line i e NOT to tree or star Termination resistor should be located at the end For short distance other topology is allowed Terminate the network by a termination...

Страница 4: ...4 IE SNC T23 4 14 04 Dimensions T2314 Transmitter with RS232 Dimensions T2414 Transmitter with RS485 Dimensions T2314L T2414L Connection see Appendix B...

Страница 5: ...IE SNC T23 4 14 04 5 Typical application wiring connection of terminals T2314 power from communication port T2314 power from external voltage source T2414 RS485...

Страница 6: ...bit registers Read Holding Registers 04 0x04 Reading of 16 bit input gates Read Input Registers 16 0x10 Setting of more 16 bit registers Write Multiple Registers Jumper and button Jumper and button ar...

Страница 7: ...g Note In case there is a need for reading of measured values from the device with higher resolution than one decimal measured values in device are stored also in Float format which is not directly co...

Страница 8: ...ce with setup software TSensor to communication protocol HWg Poseidon and set correct device address This communication protocol supports read temperature at C relative humidity one of computed value...

Страница 9: ...sure or error state of value If selected pressure unit is mBar or oz in2 or mmHg or inH2O or kPa there is shown only value number without corresponding pressure unit symbol 3 near by left display marg...

Страница 10: ...allowed manipulation It is not allowed to operate the device under conditions other than specified in technical parameters Devices are not designed for locations with chemically aggressive environmen...

Страница 11: ...connector marked RS232 directly to the PC connect power to connector marked RS485 Power voltage 6V DC from an external acdc adapter connect to pin 9 0V connect to pin 5 Also mutually connect pin 2 and...