![COMEM eSDB-10C Скачать руководство пользователя страница 59](http://html1.mh-extra.com/html/comem/esdb-10c/esdb-10c_instruction-manual_2640451059.webp)
59
Appendix D - MODBUS communications
Register
address
Operation Notes
Operation for controlling
0x1
W
Start cycle
0x2
W
Abort cycle
0x3
W
Test cycle
0x5
W
Reset Cycle
0x7
W
Reset and format test set
Operation for monitoring
0x2000 R
Salts percentage 1
0x2001 R
Temperature T1
0x2002 R
Events number
0x200C R
Temperature T2
0x200D R
Temperature T3
0x2010 R
Fan status
0x2011 R
Solenoid Valve Status
0x2012 R
Cycle Status
0x2013 R
Error Status
0x3000 R
Hours
0x3001 R
Minutes
0x3002 R
Seconds
0x3003 R
Day
0x3004 R
Month
0x3005 R
Year
Data logging
EVENT - 1
0x2100 R
Day
0x2101 R
Month
0x2102 R
Years
0x2103 R
Hours
0x2104 R
Cycles numbers
0x2105 R
Event Type
0x2106 R
Salts weight
0x2108 R
Temperature T1
0x2109 R
Temperature T2
0x210A R
Temperature T3
EVENT - ...
EVENT -
300
0x2F04 R
Day
0x2F05 R
Month
0x2F06 R
Years
0x2F07 R
Hours
0x2F08 R
Cycles numbers
0x2F09 R
Event Type
0x2F0A R
Salts weight
0x2F0C R
Temperature T1
0x2F0D R
Temperature T2
0x2F0E R
Temperature T3
MODBUS register
eSDB10/15/30
MODBUS address
Table 9
Table 10
DIP 8 DIP 7 DIP 6 DIP 5 DIP 4 DIP 3 DIP 2 DIP 1 Address
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
1
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
2
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
3
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
4
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
5
OFF
OFF
OFF
OFF
OFF
ON
ON
OFF
6
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
7
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
8
OFF
OFF
OFF
OFF
ON
OFF
OFF
ON
9
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
10
OFF
OFF
OFF
OFF
ON
OFF
ON
ON
11
OFF
OFF
OFF
OFF
ON
ON
OFF
OFF
12
OFF
OFF
OFF
OFF
ON
ON
OFF
ON
13
OFF
OFF
OFF
OFF
ON
ON
ON
OFF
14
OFF
OFF
OFF
OFF
ON
ON
ON
ON
15
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
16
Figure 16
Содержание eSDB-10C
Страница 1: ...Self dehydrating breathers eSDB 10 15 30 EN IT DE ES FR INSTRUCTION MANUAL...
Страница 64: ...64...
Страница 65: ...65...