![COMEM eSDB-10C Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/comem/esdb-10c/esdb-10c_instruction-manual_2640451013.webp)
13
Operations
Table 8
Action description
Tool Pictures/Notes
1
Inform COMEM about the
switching of the eSDB due
to a suspect overvoltage.
0039 0444 449311
2
Disconnect the supply
voltage
3
Remove the electronic box
cover unscrewing the 6
screws
B
4
Check with a tester on the
terminal 31-32 and verify
the absence of tension.
D
5
Locate the overvoltage
protection position on
the bottom left of the
electronic control board.
Look for the varistor and
the fuse.
6
Remove the Varistor
screwing the 2 screws on
the terminals and then slip
off the varistor.
A
7
Remove the fuse with its
plastic protection
Action description
Tool Pictures/Notes
8
Insert the pin of the new
varistor in the terminal then
fasten the 2 screws on the
terminal.
A
9
Mount a new Fuse in its
plastic protection.
10
Mount the Fuse on the
board with its plastic
protection.
C
11
Close the electrical box
B
12
Powering the device
The varistor has to be
assembled in the same
position of the before one
bending the pins in order to
guarantee a right position, far
from the other components.
WARNING