Confi guring the intercom directory

1. 

Access the installer menu.

2. 

Select the 

Special Settings

 menu by pressing 

 and press 

 

to access it.

INSTALLER MENU

Special Settings

3. Press button 

 to access the 

Call 

menu.

SPECIAL SETTINGS MENU

Alarms

Door open

Self-ignition

Call

Set ringtone repetition
Set call times

4. 

Press button 

 to access the 

Intercom Directory 

menu.

CALL

Intercom Directory

5. 

Press the 

 button.

INTERCOM CALLS DIRECTORY

Not assigned

Not assigned

Not assigned

Not assigned

Not assigned
Not assigned

Edit

6. Press button 

 to access the 

Con

fi gure name 

menu.

CONFIGURE DIRECTORY

Configure ViP address

Configure name

• 

Confi guring the Privacy / Doctor button

1. 

Access the installer menu.

INSTALLER MENU

Configure buttons

2. 

Select the 

Confi gure button

menu by pressing 

 and press 

 to access it.

3. 

Select the 

Confi gure Privacy/Doctor

 

menu by pressing 

 and 

press 

 to access it.

CONFIGURE BUTTONS

Configure Privacy/Doctor

1

2

4. Select the function you wish to assign to the button using 

 and 

press 

 to confi rm.

CONFIGURE PRIVACY / DOCTOR

Doctor mode
Privacy
privacy mode

5. 

Press 

 to exit and save the changes.

The Privacy function disables the ringtone for calls from the external unit 
and intercom. The Doctor function, as well as disabling the door-entry phone 
ringtone in the same way as the Privacy function, also enables automatic 
activation of the lock-release in response to a call from the external unit.

Содержание VIP System

Страница 1: ...the complete Internet Protocol system simple and versatile Installer manual www comelitgroup com ...

Страница 2: ...or Font Software that has been modified and is distributed under the Tavmjong Bah Arev names The Font Software may be sold as part of a larger software package but no copy of one or more of the Font Software typefaces may be sold by itself THE FONT SOFTWARE IS PROVIDED AS IS WITHOUT WARRANTY OF ANY KIND EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO ANY WARRANTIES OF MERCHANTABILITY FITNESS FOR A...

Страница 3: ...s external units 30 Mounting external unit Art 4682C and additional buttons Art 33433 33434 33436 30 Mounting digital directory Art 3360A 31 Mounting Vandalcom series external units 32 Connecting audio video unit Art 4662C for use with buttons on Vandalcom external unit Art 3269 1 2 32 Connecting audio unit 1682 or audio video unitArt 4682C for use with buttons on Vandalcom external unitArt 3262I ...

Страница 4: ...t 3370 71 Connecting backlit module with actuator relay Art 3327 72 Connecting IKall call button module Art 3343 3 4 6 73 Connecting IKall series audio unit for VIP system Art 1682 74 Connecting IKall series digital call module Art 3360A 75 Connecting Vandalcom series digital call modules Art 3070B and Art 3072B with IKall series external units Art 4682C or 1682 76 Connecting Vandalcom series digi...

Страница 5: ...P system means that networks can be created using cascade or branch connections with no restrictions Main features The VIP System delivers optimal performance across an intelligible infrastructure untangling the communication control security automation and monitoring apparatus needed for access and building control Multiple simultaneous audio video conversations An unlimited number of users and d...

Страница 6: ...ware for PC installation for the programming and configuration of all wired devices in the system Also allows button programming and management of names in external unit directories Includes a special cable for connection between switch 1440 and PC When connecting a PC to a VIP system the special cable supplied with software Art 1449 must be used VIP Manager Art 1449 VIP system configuration softw...

Страница 7: ...dily port in standby Flashing data passing through the port Off port not connected IN1 IN2 100 Mb riser Ethernet ports Used for the connection of distributors such as repeaters switches internal units etc OUT1 OUT2 OUT3 OUT4 10 Mb extension Ethernet port Used for the connection of distributors such as repeaters switches internal units etc External power supply terminals Connection of power supply ...

Страница 8: ...eneral the repeater will receive power from the input port and supply power to the remote device door entry phone switch repeater via the output port This distinction was made to interrupt power supply propagation between the In port and the Out port by removing Jumpers JP1 and JP2 in order to separate for example the power supplies to two risers The device even operates correctly if the output po...

Страница 9: ...tion Min 0 7 W Max 2 6 W value for complete backplate monitor product Power supply 36 57 Vdc 3A Max Dimensions H 6 2 cm W 7 2 cm D 9 cm 1 Connection terminals 2 VIP POE selector for fitting to the latter if the internal unit is used on a standard not VIP PoE network 3 RJ45 Ethernet connector for connecting the internal unit to the VIP network 4 SD Card slot For wiring details refer to the diagrams...

Страница 10: ...N1 1 2 3 4 1 Connection terminals 2 VIP POE selector for fitting to the latter if the internal unit is used on a standard not VIP PoE network 3 RJ45 Ethernet connector for connecting the internal unit to the VIP network 4 SD Card slot For wiring details refer to the diagrams section at the end of this manual We recommend using VIP Manager software Art 1449 to configure the internal unit see specif...

Страница 11: ... the end of this manual Use VIP Manager software Art 1449 to configure the internal unit see specific manual For wiring details refer to the diagrams section at the end of this manual We recommend using VIP Manager software Art 1449 to configure the internal unit see specific manual However the main parameters can also be configured directly on the device itself see page 67 Technical characteristi...

Страница 12: ...or Open terminal RTE Timed relay control terminals Power supply terminals TX TX Ethernet transmission line terminals RX RX Ethernet reception line terminals Technical characteristics Power supply 12 Vac Temperature thresholds 30 55 C Dimensions H 10 2 cm W 5 5 cm D 3 5 cm Powercom series external units Powercom module Art 3331 0 1 2 for audio video units Powercom series colour audio video unit for...

Страница 13: ...isplay Also functions as a coded electronic key module Names can be scrolled using the two search buttons or by entering the initial letter of the required name Once the right name has been found press the call button The user code can also be entered to make a direct call 1 Power supply terminals PR Programming terminals TX RX RS232 line terminals not used RS232 line negative terminal not used D ...

Страница 14: ...r audio units Door entry phone porter unit for VIP system complete with terminal block Technical characteristics Power supply 33 Vdc Temperature thresholds 30 55 C Dimensions H 10 2 cm W 5 5 cm D 3 5 cm IKall series audio unit for VIP system Art 1682 SE GND V V 1 SE Door lock connection terminals NC NO Normally closed and normally open output terminals COM Common terminal RTE GND Timed relay contr...

Страница 15: ...als COM Common terminal RTE GND Timed relay control terminals V V Power supply terminals TX TX Ethernet transmission line terminals RX RX Ethernet reception line terminals Additional call button module Versions with 3 4 and 6 buttons are available IKall call button module Art 33433 33434 33436 Digital call module complete with electronic directory with graphic LCD display Also functions as a coded...

Страница 16: ... module complete with electronic directory with graphic LCD display Also functions as a coded electronic key module The user code can be entered directly to make a call Vandalcom series digital call module for VIP system Art 3070B for Powercom external units Art 4662C and IKall external units Art 4682C Technical characteristics Power supply 12 Vac 33 Vdc Temperature thresholds 30 55 C Dimensions H...

Страница 17: ... module complete with electronic directory with graphic LCD display Name scrolling is carried out using two search buttons Once the right name has been found press the call button Vandalcom series digital call module for VIP system Art 3072B for Powercom external units Art 4662C and IKall external units Art 4682C Technical characteristics Power supply 12 Vac 33 Vdc Temperature thresholds 30 55 C D...

Страница 18: ...es audio video unit Art 4662C to complete installation Versions with 0 1 and 2 buttons are available Module Art 3262I 0 1 2 designed for audio units IKall series Module with facility for audio porter units Requires audio unit Art 1682 to complete installation Versions with 0 1 and 2 buttons are available Vandalcom series 4 button module Art 3064 C for VIP system Module with 4 additional call butto...

Страница 19: ...ld terminal Camera 2 shield terminal Camera 3 shield terminal Camera 4 shield terminal VIP system accessories Remote camera module Art 1445 Remote camera module Art 1445 transmits the video signals received from 4 cameras D D GND Technical characteristics Absorption Min 0 7 W Max 2 6 W Power supply 36 57 Vdc 3A Max Temperature thresholds 30 55 C Dimensions 4 DIN modules H 3 6 cm W 6 5 cm D 8 3 cm ...

Страница 20: ...modules H 3 6 cm W 6 5 cm D 8 3 cm 1 Terminal block for on board relay inputs and output 2 Terminals for connection of expansion module Art SK9071 3 Network connection Ethernet port 4 VIP Standard POE power supply selector Input terminal 1 Open collector output terminal Common terminal for NC NO Earth terminal Input terminal 2 On board relay normally closed terminals Earth terminal Art Sk9071 conn...

Страница 21: ...43 Technical characteristics Absorption Min 0 7 W Max 2 6 W Power supply 12 Vdc Temperature thresholds 30 55 C Dimensions 8 DIN modules H 5 5 cm W 14 cm D 9 5 cm 1 Connection terminal blocks Terminals not used Art 1443 connection terminals Art 1443 12 VDC power supply terminals A B J1 J10Relayoutputterminals PAL NTSC video output module Art 1446 Expansion module Art SK9071 For wiring details refer...

Страница 22: ...Mb 250 m Art 1440 10 Mb Art 1440 10 Mb 250 m Art 1440 100 Mb Art 1440 100 Mb 250 m Art 1440 10 Mb Art 1440 100 Mb 120 m Art 1440 100 Mb Connection distances Connection distances between external unit and Switch Art 1440 Connection distances between 2 Switches Art 1440 Art 1395 Art 1595 A Max 0 5 mm2 Ø 0 8 mm AWG 20 10 m 25 m 0 5 mm2 Ø 0 8 mm AWG 20 Comelit Art 4576 4578 10 m 25 m 1 mm2 Ø 1 2 mm AW...

Страница 23: ...nnection distance between two Switches Art 1440 Max 8 The connection distance between a Switch and a Repeater varies depending on the port used on Switch Art 1440 250 m Art 1440 Art 1447 10 Mb 120 m Art 1440 Art 1447 100 Mb 120 m Art 1447 Art 1447 Art 1447 120 m The connection distance between 2 Repeaters is always 120 m See diagram VIP 005 ConnectiondistancesfromSwitchArt 1440 RepeaterArt 1447tod...

Страница 24: ...ted Pair similar to the UTP but with a metal sheath The UTP and STP can fall into various categories Category 5 CAT 5 cables or greater must be used for the VIP system Crimping pliers 6 P 8 P We recommend using 8 pole Panduit pliers code MPT5 8A Tester for RJ45 cables The tester must only be used while the system is off The tools required for fitting are as follows 2 RJ45 connectors for each secti...

Страница 25: ...lours in some cables the white colour wires are completely white 3 Spread the wires out into a fan in the order in which you need to crimp them from left to right The cable configuration is illustrated in Table 1 and Figure A Table 1 Connector 1 Connector 2 White Orange White Orange Orange Orange White Green White Green Blue Blue White Blue White Blue Green Green White Brown White Brown Brown Brow...

Страница 26: ...each the edge of the connector 7 Make sure the wires are fully inserted by inspecting the side of the transparent connector Next insert the connector into the crimping pliers and using both hands crimp the connector so as to secure the wires The pliers should not open if they did not close fully 8 Now repeat steps 1 to 7 above to crimp the cable on the other side Complete connector example ...

Страница 27: ...rious products we recommend a document is compiled to keep track of the location of the device within the system An example of how to compile such a document is provided below For all products the VIP address is programmed using VIP Manager software Art 1449 with the exception of monitors Art 6202 Art 6304 Art 6501 and Art 1952 which can be used to set the VIP address even locally The Mac address ...

Страница 28: ...ns Art 3337 3 4 6 4662C 4662C 3331 0 1 2 3331 0 1 2 360û 2 1 3 360 5 4 2 3 1 3337 3 4 6 1 4662C 4662C 3331 0 1 2 3331 0 1 2 360û 2 1 3 360 5 4 2 3 1 3337 3 4 6 2 4662C 4662C 3331 0 1 2 3331 0 1 2 360û 2 1 3 360 5 4 2 3 1 3337 3 4 6 3 4662C 4662C 3331 0 1 2 3331 0 1 2 360û 1 360 5 4 2 3 1 3337 3 4 6 4 4662C 4662C 3331 0 1 2 3331 0 1 2 360û 2 1 3 360 5 4 2 3 1 3337 3 4 6 5 4662C 4662C 3331 0 1 2 333...

Страница 29: ...O 6PQ RS 7T U V 8WXY Z 9 X 0 PR TX RX 2 1A B C 2D E F 3G H I 4J K L 5M N O 6PQRS 7T U V 8WXYZ 9 X 0 360û 360 2 1 3 PR TX RX 1A B C 2D E F 3G H I 4J K L 5M N O 6PQ RS 7T U V 8WXY Z 9 X 0 PR TX RX 3 1A B C 2D E F 3G H I 4J K L 5M N O 6PQRS 7T U V 8WXYZ 9 X 0 360û 360 2 1 3 PR TX RX 1A B C 2D E F 3G H I 4J K L 5M N O 6PQ RS 7T U V 8WXY Z 9 X 0 PR TX RX 4 Mounting digital directory Art 3370 NC C NO LP...

Страница 30: ...5 2 1 4 33433 33434 33436 33410 33411 33412 6 3 2 1 4 8 3 2 1 33410 33411 33412 4682C 33433 33434 33436 4682C 1 3 2 1 33410 33411 33412 4682C 3 1 33433 33434 33436 33410 33411 33412 4682C 2 C 4682C 3 5 2 1 4 33 34 36 33410 33411 33412 3 3 2 1 4682C 4 3 2 1 4682C 5 33410 33411 33412 4682C 4682C 3 5 2 1 4 33433 33434 33436 33410 33411 33412 7 OPTIONAL ...

Страница 31: ... TX RX PR TX RX PR TX RX 2 1 3 PR TX RX 1 360 1A B C 2D E F 3G H I 4J K L 5M N O 6PQRS 7T U V 8WXYZ 9 X 0 360û 360 2 1 3 PR TX RX 2 1 3 PR TX RX 2 1A B C 2D E F 3G H I 4J K L 5M N O 6PQRS 7T U V 8WXYZ 9 X 0 PR TX RX PR TX RX 3 360 1A B C 2D E F 3G H I 4J K L 5M N O 6PQRS 7T U V 8WXYZ 9 X 0 360û 360 2 1 3 2 1 3 PR TX RX 4 ...

Страница 32: ... T O A L T O black orange blue black 3269 2 3269 2 4662C 4662C 4662C 4662C 2 black blue orange A L T O A L T O black orange blue black 3269 2 3269 2 4662C 4662C 4662C 4662C 3 black A L T O A L T O black orange blue black 3269 2 3269 2 4662C 4662C 4662C 4662C 1 black blue orange A L T O A L T O orange blue 3269 2 3269 2 C 4662C 4662C 4662C 5 black blue orange A L T O A L T O black orange blue black...

Страница 33: ...2 4682C 1682 3262I 2 3268I 2 3262I 2 3268I 2 3 A L T O A L T O A L T O white green orange 4682C 1682 4682C 1682 4682C 1682 4682C 1682 3262I 2 3268I 2 1 orange white green white green orange A L T O A L T O A L T O white green orange A L T O 4682C 1682 4682C 1682 4682C 1682 4682C 1682 4682C 1682 4682C 1682 3262I 2 3268I 2 3262I 2 3268I 2 2 orange white green white green orange A L T O A L T O A L T...

Страница 34: ...34 Mounting audio video unit Art 4662C or 4682C for use with additional buttons Art 3064 C 2 3 1 5 4 6 ...

Страница 35: ...t 3270 and Art 3272 can only be connected with Powercom external unit Art 4662C Art 4662C Art 3270 Art 3272 S 1 2 1 2 P R 1 Art 4662C Art 3270 Art 3272 S 1 2 1 2 P R 2 Art 4662C Art 3270 Art 3272 S 1 2 1 2 P R 3 Art 4662C S P R 6 Art 4662C Art 3270 Art 3272 S 1 2 1 2 P R 4 Art 4662C Art 3270 Art 3272 S 1 2 1 2 P R 5 ...

Страница 36: ...all external unit Art 4682C and Powercom external unit Art 4662C For mounting with external unit Art 4662C see page 34 Art 3070B Art 3072B Art 4682C 4682C V S V 1 Art 3070B Art 3072B Art 4682C 4682C S 2 Art 3070B Art 3072B Art 4682C 4682C V S V 3 Art 3070B Art 3072B Art 4682C 4682C S 4 Art 3070B Art 3072B Art 4682C 4682C 3 Art 3070B Art 3072B Art 4682C 4682C V S V 4 ...

Страница 37: ...BEN 14 5 cm 14 5 cm 1 2 2 3 145 150 cm 115 125 cm ALTO UP HAUT OBEN 4 5 cm 14 5 cm 1 2 2 3 145 150 cm 115 125 cm 2 3 4 5 1 145 150 cm 115 125 cm ALTO UP HAUT OBEN 14 5 cm 14 5 cm 1 2 2 3 145 150 cm 115 125 cm 2 3 4 5 1 1 3 2 ALTO UP HAUT OBEN 1 2 2 3 1 2 3 4 5 6 2 3 4 5 1 145 150 cm 115 125 cm 2 3 4 5 1 7 8 ...

Страница 38: ...ux monitor Art 6202 with wall bracket Art 6120 145 150 cm 115 125 cm 145 150 cm 115 125 cm 145 150 cm 115 125 cm 145 150 cm 115 125 cm 145 150 cm 115 125 cm 1 2 3 4 5 6 145 150 cm 115 125 cm 145 150 cm 115 125 cm 7 8 9 ...

Страница 39: ...39 Mounting Sette Stelle monitor Art 6501 23 cm 16 7 cm 150 cm 23 cm 16 7 cm 150 cm 23 cm 16 7 cm 150 cm 23 cm 16 7 cm 150 cm 1 2 3 4 23 cm 16 7 cm 150 cm 5 ...

Страница 40: ...40 Mounting 7Stelle monitor Art 6501 with flush mounted box Art 6517 1 2 3 4 5 6 ...

Страница 41: ...2 8 cm 115 125 cm 140 145 cm 2 1 2 CLICK 3 3 16 cm 9 cm 2 8 cm 115 125 cm 140 145 cm 2 1 2 CLICK 3 3 16 cm 9 cm 2 8 cm 115 125 cm 140 145 cm 2 1 2 CLICK 3 3 16 cm 9 cm 2 8 cm 115 125 cm 140 145 cm 2 1 2 CLICK 3 3 16 cm 9 cm 2 8 cm 115 125 cm 140 145 cm 1 2 3 4 5 6 2 1 2 CLICK 3 3 16 cm 9 cm 2 8 cm 115 125 cm 140 145 cm 7 ...

Страница 42: ...max 7 cm Lmin 6 5 cm 1 2 1 1 2 2 1 2 2 1 1 m 160 c 130 cm Lmax 7 cm Lmin 6 5 cm 1 2 2 1 130 Lmax 7 cm Lmin 6 5 cm 1 2 2 2 1 1 130 Lmax 7 cm Lmin 6 5 cm 1 1 2 2 2 1 1 13 8 cm 13 8 cm 160 cm 130 cm Lmax 7 cm Lmin 6 5 cm 1 2 1 2 1 2 2 1 2 2 1 1 1 2 3 4 5 6 1 2 1 2 1 2 1 2 2 1 2 2 1 7 8 13 8 cm 13 8 cm 160 cm 130 cm Lmax 7 cm Lmin 6 5 cm 1 2 1 2 1 2 2 1 2 2 1 1 9 ...

Страница 43: ... 5 1 160 cm 130 cm Lmin 6 cm 2 ALTO UP HAUT OBEN 1 130 c Lmax 10 cm 2 3 4 5 1 Lmin 6 cm 1 2 1 2 1 2 1 1 2 2 Lmax 10 cm ALTO UP HAUT OBEN 2 3 4 5 1 160 cm 130 cm Lmin 6 cm 1 2 1 2 1 Lmax 10 cm ALTO UP HAUT OBEN 2 3 4 5 1 160 cm 130 cm 13 8 cm 13 8 cm 1 2 Lmin 6 cm 1 2 1 2 3 4 5 6 1 2 1 2 1 1 2 2 1 1 2 1 1 2 2 7 8 Lmax 10 cm 2 3 4 5 1 Lmin 6 cm 1 2 1 2 1 2 1 1 2 2 9 10 cm 6 cm 1 2 2 1 2 1 1 2 2 10 ...

Страница 44: ...c Address During the installation of various products we recommend a document is compiled to keep track of the location of the device within the system An example of how to compile such a document is provided below For all products the VIP address is programmed using VIP Manager software Art 1449 with the exception of monitors Art 6202 and Art 5900 which can be used to set the VIP address even loc...

Страница 45: ... 224 6 7 8 33 1 6 97 1 6 7 161 1 6 8 225 1 6 7 8 34 2 6 98 2 6 7 162 2 6 8 226 2 6 7 8 35 1 2 6 99 1 2 6 7 163 1 2 6 8 227 1 2 6 7 8 36 3 6 100 3 6 7 164 3 6 8 228 3 6 7 8 37 1 3 6 101 1 3 6 7 165 1 3 6 8 229 1 3 6 7 8 38 2 3 6 102 2 3 6 7 166 2 3 6 8 230 2 3 6 7 8 39 1 2 3 6 103 1 2 3 6 7 167 1 2 3 6 8 231 1 2 3 6 7 8 40 4 6 104 4 6 7 168 4 6 8 232 4 6 7 8 41 1 4 6 105 1 4 6 7 169 1 4 6 8 233 1 4...

Страница 46: ... switch on the rear of the module Art 4662C with the same code assigned to the internal unit in accordance with the information provided in the programming table on page 45 The following procedure can be used to program buttons with VIP codes in the range between 1 and 255 only To program higher VIP addresses use VIP Manager software Art 1449 PR PR PR 1 2 4 PR 3 ...

Страница 47: ... switch on the rear of the module Art 4682C with the same code assigned to the internal unit in accordance with the information provided in the programming table on page 45 The following procedure can be used to program buttons with VIP codes in the range between 1 and 255 only To program higher VIP addresses use VIP Manager software Art 1449 PR PR 1 2 PR 3 PR 4 ...

Страница 48: ... 3337 connected to the system Make a note of the address which has just been set on module Art 3337 and the VIP address of the external unit to which it is connected as in the following example Art 4662C VIP address Art 3337 Module index 00000600 236 This procedure is used to assign an index to modules Art 3337 The module index must then be used with the VIP Manager software to complete module pro...

Страница 49: ...Art 3343 connected to the system Make a note of the address which has just been set on module Art 3337 and the VIP address of the external unit to which it is connected as in the following example Art 4682C VIP address Art 3337 Module index 00000600 236 This procedure is used to assign an index to modules Art 3343 The module index must then be used with the VIP Manager software to complete module ...

Страница 50: ... cannot be changed Accessing the installer menu Programming internal units We recommend using VIP Manager software Art 1459 to program the internal units However the main parameters of some internal units Planux 7Stelle Smart and CPS can be set directly on the product itself where necessary Planux monitor Art 6202 and Smart monitor Art 6304 only with optional buttons Art 6332 Setting the menu lang...

Страница 51: ...Press to access it 4 Press button to access the VIP address menu 5 Set the logic address for the main monitor in the same residential unit using buttons Use buttons to pass from one digit to the next 6 Move over the Slave option using buttons and press to confirm 7 Move over the Slave address option using buttons and change the address using buttons INSTALLER MENU Configure monitor CONFIGURE MONIT...

Страница 52: ...RE SELF IGNITION Intercom Self ignition Alarms Edit Lock release Actuator Activate output Function disabled 4 Select the function you wish to assign to the button using and press to confirm 5 Once the desired function has been selected press to change the settings If the Intercom function is selected CONFIGURE VIP ADDRESS 0 0 0 0 0 1 0 1 ViP address Left Right Slave Master Backplate 1 Active Selec...

Страница 53: ...at rest time Configuration during call 5 Select the fields which can be changed using and change the value using or RELAY DURING CALL Door 0 0 0 0 0 0 0 0 Interlocutor Active Left Right Relay 1 Door 0 0 0 0 0 0 0 0 Interlocutor Active Relay 1 6 Press to exit and save the changes ACTUATOR SETTING 0 0 0 0 0 1 0 1 ViP address Left Right Output Module 255 Active 0 1 If the Actuator function is selecte...

Страница 54: ...ess Configure name Configuring the Privacy Doctor button 1 Access the installer menu INSTALLER MENU Configure buttons 2 Select the Configure buttons menu by pressing and press to access it 3 Select the Configure Privacy Doctor menu by pressing and press to access it CONFIGURE BUTTONS Configure Privacy Doctor 1 2 4 Select the function you wish to assign to the button using and press to confirm CONF...

Страница 55: ...is pressed The Backplate function determines whether to call the main or secondary internal unit with the same VIP address 11 Press to exit and save the changes Configuring the self ignition directory 1 Access the installer menu 2 Select the Special Settings menu by pressing and press to access it INSTALLER MENU Special Settings 3 Select the Self ignition menu by pressing and press to access it SP...

Страница 56: ...ht Edit S o u t h g a t e 7 Enter the desired name using buttons to change the letters to move right or left and to delete EDIT ENTRY Configure Name S M I T H Left Right Edit CONFIGURE DIRECTORY Configure ViP address Configure name CONFIGURE VIP ADDRESS 0 0 0 0 0 1 0 1 ViP address Left Right Camera number Automatic camera 1 8 Press button to return to the previous menu 9 Select the Configure VIP a...

Страница 57: ...to return to the previous menu Setting the Door Open function The function can be used to monitor the input of an external unit programmed with the Door Open function When the input is opened or closed the key LED on the monitor lights up to indicate that the door is open 1 Access the installer menu 2 Select the Special Settings menu by pressing and press to access it INSTALLER MENU Special Settin...

Страница 58: ...0 0 3 0 0 1 0 0 1 6 Press to exit and save the changes Setting the ringtone repetition Setting the Alarm function This menu can be used to set the VIP address which will be contacted when a priority call is sent The procedure applies for all 4 call types the example below illustrates a Panic priority call 1 Access the installer menu 2 Select the Special Settings menu by pressing and press to acces...

Страница 59: ...ition Set call times SET CALL TIMES Intercom talk time Talk time Reply wait time Reset wait time 4 Select the Reply wait time menu by pressing and press to access it 5 Change the value using buttons SET REPLY WAIT TIME Reply wait time 0 6 0 6 Press to exit and save the changes Within this menu the time can be set for various functions The Reply wait time setting is shown below as an example which ...

Страница 60: ...Left Right Normally open Monostable 0 5 0 0 Minutes 0 0 Hours Days 0 0 0 0 The output is set as Normally open by default tick the box next to Normally open to change this setting to Normally closed The output is set as Monostable by default tick the box next to Monostable to change this setting to Bistable Fill in the Activation period fields for Monostabile mode 5 Press to exit and save the chang...

Страница 61: ...0 Active The VIP address field identifies the internal unit or CPS to which you want to divert the call The Wait time field identifies the wait time before the call is diverted 5 Press to exit and save the changes Reset configuration This function can be used to restore the factory set values of the monitor deleting all configurations applied in the meantime 1 Access the installer menu 2 Select th...

Страница 62: ...a specific device Master INTERCOM Configure ViP address Slave 1 1 Access the Configure VIP address menu to set the address of the device you want to associate with the intercom function 2 Select whether to call the Master or Slave backplate for the set address If you select Slave you will also need to set the exact number of the slave as desired Self ignition function This function can be used to ...

Страница 63: ... 4 Select whether to interact with the relay of the external unit making the call or a different one If you select External unit you will need to configure its VIP address Actuator function This function is used to activate the relay output of an IO actuator module or that of an expansion device connected to it Configure ViP address ACTUATOR Module 1 Output 1 1 Access the Configure VIP address men...

Страница 64: ...P 169 254 241 41 A 16 GW 0 0 0 0 ID 00000001 SUB 0 SW 1 5 3 Reset configuration This function can be used to restore the factory set values of the monitor deleting all configurations applied in the meantime CONFIGURE MONITOR About ViP address Reset configuration CONFIGURE MONITOR About ViP address Reset configuration CONFIRM Continue CANCEL Special Settings Actuator Directory This menu can be used...

Страница 65: ...ure Name Master Slave 1 2 Access the Configure Name menu to set the name which will appear in the directory 3 Access the Configure VIP address menu to enter the address of the device you want to associate with the call 4 Select whether to call the Master or Slave device If you select Slave you will also need to set the exact number of the device to call Set ringtone repetition This menu can be use...

Страница 66: ...ce which will be called when an alarm call is made 2 Select whether to activate the audio message when the call is sent Door open This menu can be used to set the address of the external units to be monitored DOOR OPEN 00002003 C 1 Access the Address menu by pressing the icon to add the address of the door to be monitored Activate output This menu can be used to set the operating mode of the relay...

Страница 67: ...ess About Associated camera Associated video output ViP address About Associated camera Associated video output ViP address About Associated camera Associated video output Active Confirm Cancel Camera ViP address Automatic camera Camera number 00002001 Setting the associated video output Advanced Settings ViP address About Associated camera Associated video output Advanced Settings ViP address Abo...

Страница 68: ...O JKL GHI WXYZ TUV PQRS Advanced Settings ViP address About Associated camera Associated video output ViP address About Associated camera Associated video output ViP address About Associated camera Associated video output Confirm Cancel Camera ViP address Automatic camera Camera number ViP address About Associated camera Associated video output ViP address About Associated camera Associated video ...

Страница 69: ...n actuator module Art 1443 or of an extension unit connected to it The following example illustrates the function configuration procedure for an Alarm call the same also applies for the other types available in the menu In the module field select whether to activate an output on board the actuator Art 1443 Builtin or specify the number of the expansion device with which you want to interact In the...

Страница 70: ... J2 1395 0 3 2 0 0 1 2 RX RX TX E T R D O N O N C TX C O M 4662C L 1441 OUT 4 3 OUT OUT 2 1 IN 2 1 IN 1440 OUT 1 N C 6203W N V V AL G N D P F C S S S 6231 6202W 0 V P A N C F P V 0 C N 1 OP OP 0 V 1 OUT AL 6304 OUT 1 AL 1 N C P F C IN 1 S N A P V 0 V 0 AL OUT 1 V 0 OP OP 3 N C S P F C N A P V 0 6501 1 2 ...

Страница 71: ...1 IN 1440 OUT 1 N C 6203W N V V AL G N D P F C S S S 6231 6202W 0 V P A N C F P V 0 C N 1 OP OP 0 V 1 OUT AL 1395 0 3 2 0 0 1 2 3370 D D X R X T R P RX RX TX E T R D O N O N C TX C O M 4662C J1 J2 J1 J2 6304 OUT 1 AL 1 N C P F C IN 1 S N A P V 0 V 0 AL OUT 1 V 0 OP OP 3 N C S P F C N A P V 0 6501 1 2 ...

Страница 72: ... IN 2 1 IN 1440 OUT 1 N C 6203W N V V AL G N D P F C S S AL OUT 1 V 0 OP OP 1 N C 0 V P F C N A P V 0 6202W 6231 S S 6231 6202W 0 V P A N C F P V 0 C N 1 OP OP 0 V 1 OUT AL S S C F P D N G AL 6203W C N 1 4662C 3327 M O C TX C N O N O D R T E TX RX RX 2 1 0 0 2 3 0 1395 N O N C C O M SW1 12 12 ...

Страница 73: ...OUT 4 3 OUT OUT 2 1 IN 2 1 IN 1440 OUT N V V S 6231 6202W 0 V P A N C F P V 0 C N 1 OP OP 0 V 1 OUT AL E S NC NO D N G V V M O C 4682C R T E RX RX TX TX 1595 120 230 V 33436 AL OUT 1 V 0 OP OP 3 N C S P F C N A P V 0 6501 100 240 V 1 2 6304 OUT 1 AL 1 N C P F C IN 1 S N A P V 0 V 0 ...

Страница 74: ...VIP system Art 1682 VIP 001IE J1 J1 J2 L 1441 OUT 4 3 OUT OUT 2 1 IN 2 1 IN 1440 OUT N V V E S NC NO D N G V V M O C 1682 R T E RX RX TX TX 1595 120 230 V 33436 1 N C 6203W AL G N D P F C S S 100 240 V 6203B 1 N C 6203W AL G N D P F C S S 6203B ...

Страница 75: ... V S V 1 1445 CN 1 S V 2 H H S V 3 H S V 4 H D D G N D A U X G N D E S NC NO D N G V V M O C 4682C R T E RX RX TX TX RX RX TX TX ORANGE WIRE WHITE ORANGE WIRE WHITE GREEN WIRE GREEN WIRE 1595 120 230 V Vac 24 Vac 24 485 D D 485 P R G D N G S 3360A J2 J1 J2 J1 1952 1 N C 6304 OUT 1 AL 1 N C P F C IN 1 S N A P V 0 V 0 ...

Страница 76: ...S 6231 6202W 0 V P A N C F P V 0 C N 1 OP OP 0 V 1 OUT AL 1 N C 6203W AL G N D P F C S S AL OUT 1 V 0 OP OP 3 N C S P F C N A P V 0 6501 100 240 V 1682 3268I 1 3070B X T R X R P D S J2 J1 S YELLOW V BLUE S D 3072B 12 12 P R X R T X 12 12 V V V V V BROWN 2E7T000696 D D Connecting Vandalcom series digital call modules Art 3070B and Art 3072B with IKall series external units Art 4682C or 1682 VIP 002...

Страница 77: ...C N A P V 0 6501 100 240 V RX RX TX TX ORANGE WIRE WHITE ORANGE WIRE WHITE GREEN WIRE GREEN WIRE 2 1 0 0 1 2 0 1395 4662C 3269 1 M O C TX C N O N O D R T E TX RX RX 3270 X T R X R P 12 12 D D S J2 J1 S YELLOW ORANGE S D D 3272 12 12 P R X R T X 2M1500299 Connecting Vandalcom series digital call modules Art 3270 and Art 3272 with Powercom series external unit Art 4662C VIP 001IE ...

Страница 78: ...064 C CV3 E S NC NO D N G V V M O C R T E RX RX TX TX 1595 120 230 V 4682C 3268I 1682 3262I Connecting Art 3064 C with audio video unit 4682C or audio unit Art 1682 Use the cable included in Art 3262I Art 3268I Remove jumper ...

Страница 79: ...C N 1 OP OP 0 V 1 OUT AL S V 1 1445 CN 1 S V 2 H H S V 3 H S V 4 H D D G N D A U X G N D 1952 1 N C 6304 OUT 1 AL 1 N C P F C IN 1 S N A P V 0 V 0 E S NC NO D N G V V M O C 4682C R T E RX RX TX TX RX RX TX TX ORANGE WIRE WHITE ORANGE WIRE WHITE GREEN WIRE GREEN WIRE 1595 120 230 V Vac 24 Vac 24 485 D D 485 P R G D N G S 3360A J2 J1 J2 J1 ...

Страница 80: ...C K P S E S NC NO D N G V V M O C 4682C R T E RX RX TX TX RX RX TX TX ORANGE WIRE WHITE ORANGE WIRE WHITE GREEN WIRE GREEN WIRE 1595 120 230 V Vac 24 Vac 24 485 D D 485 P R G D N G S 3360A J2 J1 J2 J1 MONITOR 1952 1 N C 6304 OUT 1 AL 1 N C P F C IN 1 S N A P V 0 V 0 Connecting PAL NTSC module Art 1446 VIP 007I ...

Страница 81: ...0 V P F C N A P V 0 6202W 6231 S OUT 1447 IN E S NC NO D N G V V M O C 4682C R T E RX RX TX TX RX RX TX TX ORANGE WIRE WHITE ORANGE WIRE WHITE GREEN WIRE GREEN WIRE 1595 120 230 V Vac 24 Vac 24 485 D D 485 P R G D N G S 3360A J2 J1 J2 J1 Connecting repeater module Art 1447 VIP 005 ...

Страница 82: ... OP OP 0 V 1 OUT AL AL OUT 1 V 0 OP OP 1 N C 0 V P F C N A P V 0 6202W 6231 S 6231 6202W C N 1 0 2 3 0 1441 0 5 5 OUT 1440 IN 1 2 IN 1 2 OUTOUT 3 4 OUT RS 485 SK9071 B IN 2 1 1 CN 1443 IN D D D N G V 12 G N D D N G C O M OC 1 NC NO 12V 24V AC DC VIP 201 A B A B A B A B A D D B A B A D D B A B A B A B A B A 1234 67 5 8 ON SW 4902 SK9071 B A B A B A B A B A D D B A B A D D B A B A B A B A B A 1234 6...

Страница 83: ... 2 100mA MAX 12 Vdc AL OUT 1 V 0 OP OP 1 N C 0 V P F C N A P V 0 6202W 6231 S V V N OUT 1440 IN 1 2 IN 1 2 OUTOUT 3 4 OUT 1441 L 12 Vdc LED FUNCTION ALARM FIRE ALARM CFP Request to exit RTE button input variant VIP RTE Planux VIP output and input variant VIP FMP ...

Страница 84: ...4 OUT 1441 L 12 Vdc 12 Vdc 100mA MAX LED FUNCTION ALARM FIRE ALARM CFP V V N OUT 1440 IN 1 2 IN 1 2 OUTOUT 3 4 OUT 1441 L 6304 OUT 1 AL 1 N C P F C IN 1 S N A P V 0 V 0 12 Vdc 100mA MAX LED FUNCTION ALARM PANIC CFP 7Stelle output and input variant VIP FM7 Smart output and input variant VIP FMS ...

Страница 85: ...ARM CFP Easycom output and input variant VIP FME Vin Vout 2G60000653 CV1 4682C 3268I E S NC NO D N G V V M O C R T E RX RX TX TX 1595 120 230 V 1682 3262I 2G60001021 12Vdc 16Vdc MAX N 4 Connection of Vandalcom nameplate lighting lamp with audio unit Art 1682 or audio video unit Art 4682C Ikall ...

Страница 86: ... F C N A P V 0 V V N OUT 1440 IN 1 2 IN 1 2 OUTOUT 3 4 OUT 1441 L O N C N C 12 24V AC DC 1122 A 12V 470nF 6304 OUT 1 AL 1 N C P F C IN 1 S N A P V 0 V 0 OUT 1 AL 1 N C P F C IN 1 S N A P V 0 V 0 1229 20 m MAX V V N OUT 1440 IN 1 2 IN 1 2 OUTOUT 3 4 OUT 1441 L O N C N C 12 24V AC DC 1122 A 12V 470nF 1 N C 6203W AL G N D P F C S S 6203B 1229 20 m MAX 1 N C AL G N D P F C S S Connecting Smart additio...