4.2.2 Quick programming
For the quick programming of the following functions:
•
generic actuator (ACT)
•
internal intercom calls (INT)
•
internal paging calls (PAG)
•
Self activation main external unit (AI)
•
Automatic lock-release (Doctor mode) (D)
1
f
Set the
S2
DIP switches combination corresponding to the
functions that you want to programme
for
ALL KEYS
as
.
Example
choose
S2
DIP switches combination:
DIP 1
DIP 2
DIP 3
DIP 4
0
1
0
0
for set all the following function:
PAG /
INT
AI
NULL
ACT
4.2.3 Special key programming
If the preset function do not reflect requirements, EACH KEY can be programmed differently by carrying out the steps below.
Special key programming allow to programm the following functions:
•
generic actuator and coded actuator (ACT)
•
internal intercom calls and general intercom calls to another user code (INT)
•
internal paging calls and general paging to another user code (PAG)
•
Self activation main external unit (AI)
•
Automatic lock-release (Doctor mode) (D)
4.2.3.1 HOW TO PROGRAM THE
ACTUATOR FUNCTION
Example: key
√
Take note of the S1 setting and restore it when programming is complete
1
Enter programming mode
f
Set S2 DIP-switch 5-6 to the combination 01
» the Privacy LED flashes
ON
1 2 3 4 6 7
5
8
2
2.1 Choose the function:
refer to the
S2
DIP-switches
combination in which the actuator function (
ACT
) is listed for the keys you wish to program.
Example: 1010
ON
1 2 3 4 6 7
5
8
2.2 Addressing:
f
for generc actuator
set S1 DIP switches to the combination 11111111
f
for coded actuator
set S1 DIP switches with the desired address in accordance with
ON
1 2 3 4 6 7
5
8
3
Select the key to be associated with the function
f
Press and release the key to be associated with the function
» the lock-release LED lights up
» a confirmation tone will sound.
4
Exit programming mode
f
To exit programming mode, set S2 DIP switches 5-6 to the combination 00
» the Privacy LED switches off
ON
1 2 3 4 6 7
5
8
5
When programming is complete,
f
Set
S2
DIP switches 1-2-3-4 to the combination 1111 (
PROG
setting). In this DIP switch
setting, the keys control the programmed functions; the NON-programmed keys control
functions referred to on line 0000 (
"4.2.1 Preset function table")
.
f
Restore the user code setting on
S1
.
ON
1 2 3 4 6 7
5
8
ON
1 2 3 4 6 7
5
8