20
20
EN
S1-5
S1-4
S1-3
S1-2
S1-1
12345678
DI
P
S1-8
S1-6
S1-7
S1-4
S1-3
S1-2
S1-5
S1-1
A
P1
P2
P3
P4
P5
P6
DIP
6
DIP
7
DIP
8
S1
Default
0
0
0
A
Actuator
Internal ignition /
Video request
Switchboard call
Single-family
intercom call
Two-family
intercom call
¹
Doctor
A
Single-family
intercom call
Two-family
intercom call
¹
Switchboard call
Single-family
intercom call
Two-family
intercom call
¹
Doctor
1
0
0
A
Single-family
intercom call
Doctor
Switchboard call
Single-family
intercom call
Two-family
intercom call
¹
Doctor
0
1
0
A
Two-family
intercom call
¹
Doctor
Switchboard call
Single-family
intercom call
Two-family
intercom call
¹
Doctor
1
1
0
A
Single-family
intercom call
Internal ignition /
Video request
Switchboard call
Single-family
intercom call
Two-family
intercom call
¹
Doctor
0
0
1
A
Two-family
intercom call
¹
Internal ignition /
Video request
Switchboard call
Single-family
intercom call
Two-family
intercom call
¹
Doctor
1
0
1
A
Switchboard call
Internal ignition /
Video request
Switchboard call
Single-family
intercom call
Two-family
intercom call
¹
Doctor
0
1
1
A
Switchboard call
Actuator
Switchboard call
Single-family
intercom call
Two-family
intercom call
¹
Doctor
1
1
1
Description of button functions and settings
Settings for bracket Art. 5714KC and Style door-entry phone Art. 2608
Position of the microswitches for bracket Art. 5714KC and Style door-
entry phone Art. 2608
The values of
S1-1
,
S1-2
,
S1-3
,
S1-4
and
S1-5
define the
call address
of the bracket and door-entry phones as shown in the table below.
Ź
For door-entry phones Art. 2608, Art.
2610 and Art. 2628, set dip switches
S1-6, S1-7, S1-8
to
OFF
Cod.
Two-fam.
intercom
S1
Cod.
Two-fam.
intercom
S1
Cod.
Two-fam.
intercom
S1
Cod.
Two-fam.
intercom
S1
1
A
9
E
17
I
25
M
2
A
10
E
18
I
26
M
3
B
11
F
19
J
27
N
4
B
12
F
20
J
28
N
5
C
13
'
21
K
29
O
6
C
14
'
22
K
30
O
7
D
15
H
23
L
8
D
16
H
24
L
The values of
S1-6, S1-7
and
S1-8
define the
operating mode
of the Bravo Kit System, as shown in the table below.
¹ For two-family intercom calls (between door-entry phones and/or door entry monitors), set the 2 users to contiguous call addresses (marked with the
same letter AA…CC..OO in the microswitch programming table on page 20).