![Comelit 8461V Скачать руководство пользователя страница 23](http://html1.mh-extra.com/html/comelit/8461v/8461v_technical-manual_2640083023.webp)
23
Programming buttons for other functions
Legend
Lock- release
AI
Self-ignition
K
Guardian doorentry phone call
D
Doctor
PROG
Programmed functions
Example:
on a monitor with user code 5, P1 programming = self-ignition, P2= Doctor.
1.
Set S2 DIP switch 6 to the combination 01.
»
the privacy LED flashes.
S2 DIP
1 2 3 4 5 6
0 0 0 0 0 1
S2
2.
Refer to the table on page
and select a combination in which the desired/necessary functions are listed for the keys
you wish to program.
E.g. 1
: for P1= self-ignition, P2= Doctor, set S2 DIP switches 1-2-3-4 to the combination 0110 (P1=AI,P2=D).
3.
Press and release the keys to which you wish to assign the functions
»
the lock-release LED lights up.
»
une tonalité de confirmation retentit.
4.
To exit programming mode, set S2 DIP switches 5-6 to the combination 00
»
the privacy LED switches off.
5.
When programming is complete, set S2 DIP switches 1-2-3-4 to the combination 1111.
DIP S2
Art. 6721W(/BM) + Art. 6734
DIP 1
DIP 2
DIP 3
DIP 4
P1
P2
P3
P4
P5
0
0
0
0
AI
D
1
0
0
0
AI
D
0
1
0
0
AI
1
1
0
0
K
0
0
1
0
1
0
1
0
0
1
1
0
AI
D
K
1
1
1
0
AI
0
0
0
1
D
AI
1
0
0
1
K
AI
0
1
0
1
K
1
1
0
1
K
0
0
1
1
AI
D
1
0
1
1
0
1
1
1
1
1
1
1
PROG