18
Standard configuration for DIP switches 1-2-3-4
Monitor configuration
Standard configuration for soft-touch keys
Legend
Lock- release
ACT
Actuator
AI
Self-ignition
K
Guardian door-entry phone call
D
Doctor
INT
General or selective programmable intercom - singlefamily call standard for KIT 8461
INTb
General or selective programmable intercom - two-family call standard for KIT 8461
NULL
No function or DO NOT use
PROG
Programmed functions, see pages
19-23
.
In this Dip switch setting, the buttons control the programmed functions; the NON-programmed buttons
control functions referred to on line 0000 (default).
Operation
Answer incoming call
Activation/deactivation automatic answer mode
Press the soft-touch audio activation key to answer incoming call.
f
Press on the audio activation key for 10 sec
»
(ACTIVATION)
+ audio LED with FIXED ILLUMINATION
»
(DEACTIVATION)
+ audio LED OFF
DIP S2
Art. 6721W(/BM) + Art. 6734
DIP 1
DIP 2
DIP 3
DIP 4
P1
P2
P3
P4
P5
0
0
0
0
ACT
AI
NULL
D
NULL
1
0
0
0
NULL
AI
INT
INTb
D
0
1
0
0
INT
AI
INTb
ACT
NULL
1
1
0
0
ACT
NULL
NULL
NULL
K
0
0
1
0
ACT
ACT
ACT
ACT
ACT
ACT
1
0
1
0
INT
ACT
NULL
NULL
INTb
0
1
1
0
AI
D
K
NULL
NULL
1
1
1
0
INTb
INT
AI
INT
NULL
0
0
0
1
NULL
NULL
D
AI
INTb
1
0
0
1
K
NULL
NULL
NULL
AI
0
1
0
1
NULL
K
NULL
ACT
INT
1
1
0
1
NULL
NULL
NULL
K
ACT
0
0
1
1
INTb
AI
INT
ACT
D
1
0
1
1
INT
INT
INT
INT
INT
0
1
1
1
NULL
NULL
NULL
NULL
NULL
NULL
1
1
1
1
PROG