Comelit 8461V Скачать руководство пользователя страница 10

10

DIP 1

DIP 2

DIP 3

DIP 4

DIP 5

DIP 6

DIP 7

DIP 8

 

ON 

 

The lock-

release relay 

and the 

second relay 

are controlled 

by 2 separate 

buttons (e.g. 

lock-release 

button and 

actuator 

button)

 

ON 

 

lock-release 

activation time: 

8 sec.

 

ON 

 

relay activation 

time: 8 sec.

 

ON 

 

reset wait time: 

1 sec.

 

ON 

 

Call 

transmission: 

triple

 

ON 

 

confirmation 

tones (call, 

lock-release, 

relay, audio 

enabled): 

disabled

 

ON 

 

Camera 

lighting LED: 

disabled

 

ON 

 

LED lighting 

of nameholder 

front panels: 

OFF

 

OFF 

 

The lock-

release relay 

and the 

second relay 

are controlled 

by a single 

button (e.g. 

lock-release 

button)

 

OFF 

 

lock-release 

activation time: 

2 sec.

 

OFF 

 

relay activation 

time: 2 sec.

 

OFF 

 

reset wait time: 

10 sec.

 

OFF 

 

Call 

transmission: 

single

 

OFF 

 

confirmation 

tones (call, 

lock-release, 

relay, audio 

enabled): 

enabled

 

OFF 

 

Camera 

lighting LED: 

enabled

 

OFF 

 

LED lighting 

of nameholder 

front panels: 

ON

External unit settings

 

f

Set the DIP-switches of S1 corresponding to the function that you want to programme as shown in the table below

Содержание 8461V

Страница 1: ...EN TECHNICAL MANUAL Technical manual for single family KIT Art 8461V Passion Technology Design...

Страница 2: ...in proximity to power supply cables 230 400V Do not insert objects or pour liquids into the device Installation mounting and assistance procedures for electrical devices must only be performed by spe...

Страница 3: ...28 Programming of door entry phone Art 2638 28 Wiring diagrams 29 KIT 8461V standard single family system Switching on voltage check with system in standby 29 KIT 8461V expansion for two family syste...

Страница 4: ...cessoires et mat riaux non d origine Tous les produits sont conformes aux prescriptions des directives 2014 30 UE 2014 35 UE L application du marquage CE atteste cette conformit viter de placer les fi...

Страница 5: ...UTP5 cat 5 0 2 mm2 0 5 mm AWG 24 100 m 330 feet 60 m 195 feet 0 28 mm2 0 6 mm AWG 23 100 m 330 feet 60 m 195 feet 0 5 mm2 0 8 mm AWG 20 100 m 330 feet 60 m 195 feet 1 mm2 1 2 mm AWG 17 100 m 330 feet...

Страница 6: ...re l apparecchio interrompere l alimentazione per circa 1 minuto To reset the operation after a short circuit cut off mains voltage for about 1 minute Apres un court circuit pour remettre en fonction...

Страница 7: ...k release enabled audio enabled system engaged 6 Transparent front panel with label holder in 1 2 4 button versions default 1 button f f To send the call touch the button corresponding to the user you...

Страница 8: ...8 Installation 1 2 OPEN 3 1 2 2 1 163 cm 130 cm 5 2 1 CAUTION Tighten properly to avoid leaks 4 COM L LRTE 6 7 optional...

Страница 9: ...E JOHN SMITH PETER WHIT 8 9 Labels must be made of non conductive material so as not to compromise the operation of the soft touch buttons Before fixing the screw make sure that you do not need to pro...

Страница 10: ...ting LED disabled ON LED lighting of nameholder front panels OFF OFF The lock release relay and the second relay are controlled by a single button e g lock release button OFF lock release activation t...

Страница 11: ...ion you want to program as shown in the table on page 11 Reset the configuration of the DIP switches of S1 Code Dip Switch ON Function 1 1 button 1 enabled with call address 1 default 2 2 buttons 1 2...

Страница 12: ...ing a generic call address 2 1 example 3 4 5 1 2 3 4B Take note of the DIP switch settings NOTE Fig 3 Set the user code on Dip Switches S1 see table A on page 13 Reset the configuration of the DIP swi...

Страница 13: ...74 2 4 7 104 4 6 7 134 2 3 8 164 3 6 8 194 2 7 8 224 6 7 8 15 1 2 3 4 45 1 3 4 6 75 1 2 4 7 105 1 4 6 7 135 1 2 3 8 165 1 3 6 8 195 1 2 7 8 225 1 6 7 8 16 5 46 2 3 4 6 76 3 4 7 106 2 4 6 7 136 4 8 166...

Страница 14: ...er code setting see table on page 13 8 S2 Micro switches for programming keys and functions DIP 1 2 3 4 for key function programming DIP 5 6 access to programming DIP 7 for power supply voltage manage...

Страница 15: ...led continuous flashing device in programming mode 4 flashes system engaged LED AUDIO 6 steady with call audio activated steady idle automatic answer activated continuous flashing incoming call Lock r...

Страница 16: ...16 Installation 1C 1B 1A 4 3 2 6 2 1 5 optional fixing 115 mm 160 mm...

Страница 17: ...17 Removing Fitting the terminal Fitting upgrade KIT Art 6734W 3 1 2 L L C F P 1 C F P 2 1 2 3 to remove 3 2 1 2 3 1 2 1 7 8 5 1 1 2 2 2 4 1 2 2 6...

Страница 18: ...0000 default Operation Answer incoming call Activation deactivation automatic answer mode Press the soft touch audio activation key to answer incoming call f f Press on the audio activation key for 10...

Страница 19: ...o a maximum of 3 internal units For group calls select the desired intercom codes simultaneously max 3 Advanced monitor configuration Programming for intercom call General intercom function allowing c...

Страница 20: ...page 13 go to point 3 E g 2 for P3 single family intercom set S2 DIP switches 1 2 3 4 to the combination 1000 or 0011 or 1011 P3 INT set S1 with address 2 in accordance with table B on page 19 go to p...

Страница 21: ...internal unit enters audio mode At this point the 2 operators will be communicating with each other Step 2 intercom call programming Operator 1 f f Press the key you want to program to call operator 2...

Страница 22: ...ACT set S1 with address 125 in accordance with table A on page 13 go to point 3 3 Press and release the key to be associated with the function the lock release LED lights up a confirmation tone will s...

Страница 23: ...E g 1 for P1 self ignition P2 Doctor set S2 DIP switches 1 2 3 4 to the combination 0110 P1 AI P2 D 3 Press and release the keys to which you wish to assign the functions the lock release LED lights u...

Страница 24: ...the switchboard 3 times 3 confirmation tones are emitted to change the ringtone for intercom calls made from the internal unit 4 times 4 confirmation tones are emitted to change the floor door call r...

Страница 25: ...1 2 3 4 combination Intercom address absent Range function and min max addresses absent Ringtone reset Programming reset Take note of the S2 S1 setting and restore it when programming is complete 1 2...

Страница 26: ...he call If the system is not busy The receiver of the call can press the audio key or pick up the handset to communicate with the caller Press the audio button again or hang up the handset to terminat...

Страница 27: ...ll toggle between the external units activating alternately the main external unit and the secondary external unit With the switching device Art 1405 it is possible to install only 1 main external uni...

Страница 28: ...28 Installation of door entry phone Art 2638 Programming of door entry phone Art 2638 3 2 1 9 8 7 6 5 140 145 cm 115 125 cm 4 Set the user code on Dip Switches U2 as indicated in the table on page 13...

Страница 29: ...stem Switching on voltage check with system in standby MNVK 039QC Local lock release button ON 8 5 7 6 4 3 2 1 1234 67 5 8 ON C F P L L C F P 1 2 6721W 6721W BM L L O D E T R NO SE SE NC C M O C 1209...

Страница 30: ...all addresses 1 2 see page 11 Local lock release button 8461V ON 8 5 7 6 4 3 2 1 1234 67 5 8 ON C F P L L C F P 1 2 L L O D E T R NO SE SE NC C M O C 1209 L N 110 240V L2 L2 L1 L1 4893 LM LM OUT L IN...

Страница 31: ...L L 1216 ON 8 5 7 6 4 3 2 1 1234 67 5 8 ON C F P L L C F P 1 2 LM LM OUT L IN L IN L OUT L 1214 2C LM LM OUT L IN L IN L OUT L 1214 2C C F P L L C F P 1 2 ON 8 5 7 6 4 3 2 1 1234 67 5 8 ON 6721W 6721W...

Страница 32: ...r information regarding operating modes please refer to Operation section page 26 Local lock release button N C contact for door open indication Door open indication not available 8461V L L O D E T R...

Страница 33: ...not available 8461V L L O D E T R NO SE SE NC C M O C 1209 L N 110 240V L2 L2 L1 L1 4893 1404 L M L M L S L S LP IN MAX ON 8 5 7 6 4 3 2 1 MIN ON 8 5 7 6 4 3 2 1 LP OUT A B JP1 ON 8 5 7 6 4 3 2 1 123...

Страница 34: ...216 1404 L M L M L S L S LP IN MAX ON 8 5 7 6 4 3 2 1 MIN ON 8 5 7 6 4 3 2 1 LP OUT A B JP1 ON 8 5 7 6 4 3 2 1 1234 67 5 8 ON C F P L L C F P 1 2 LM LM OUT L IN L IN L OUT L 1214 2C L L 1216 L N 110 2...

Страница 35: ...ive manual Local lock release button 8461V L L O D E T R NO SE SE NC C M O C 1209 L N 110 240V L2 L2 L1 L1 4893 C N O C N L L L OUT L IN L IN L OUT LM LM 1214 2C 1256 12 24V AC DC 12V 1200 230V ON 8 5...

Страница 36: ...L2 L1 L1 4893 1234 67 5 8 ON 1409 G N D A N I 3 V S 3 2 S V 2 S 1 1 V L L L OUT L OUT IN IN 230V 12V 1200 C F P L L C F P 1 2 ON 8 5 7 6 4 3 2 1 1234 67 5 8 ON S1 S2 A P 6721W 6721W BM MNVK 015QC To b...

Страница 37: ...21W BM 6710 S S1 S2 A P MNVK Q21 Additional monitors Art 6721W BM do not include a backplate P 1234 67 5 8 ON 1234 67 5 8 ON CV5 ON 8 5 7 6 4 3 2 1 1234 67 5 8 ON C F P L L C F P 1 2 C F P L L C F P 1...

Страница 38: ...P 1 2 6721W 6721W BM 6721W 6721W BM 6710 6721W BM 6710 6721W BM 6710 6721W 6721W S S S S1 S2 A P S1 S2 A P S1 S2 A P S1 S2 A P MNVK Q22 Additional monitors Art 6721W BM do not include a backplate LM L...

Страница 39: ...2610 S P F C P F C L L S C P 2 2 P F C L L P F C S S S1 S2 SW1 6228W 6228B 1209 1214 2C SW3 S2 S1 2628 S P F C P F C L L S C P 3 3 2638 6721W 6721W BM MNVK FC L L O D E T R NO SE SE NC C M O C 1209 L...

Страница 40: ...release button If there are a number of door entry phones or monitor brackets with the same user code connect the CFP button to one only all the devices will ring simultaneously 20 m MAX Use screened...

Страница 41: ...41...

Страница 42: ...w w w c o m e l i t g r o u p c o m Via Don Arrigoni 5 24020 Rovetta BG Italy 2nd edition 04 2016 code 2G40001601...