3
4
5
6
7
8
9
1
2
3
Art.1456
Art.1456S
FLOOR VIP SYSTEM GATEWAY
SOLO CON CAVO ROSSO COMELIT 2E7T000500
ONLY WITH COMELIT RED CABLE 2E7T000500
FIXED POE
SETTABLE POE
NO POE
HOME 1
HOME 2
HOME 3
HOME 4
Description
Article 1456 / 1456S is a single-apartment gateway that:
• can serve up to a maximum of 15 slave devices connected to the apartment;
• answer calls from a external unit via a virtual door entry monitor App for smart phone/tablet or using a normal GSM or
landline telephone;
• incorporates the SIP protocol to enable telephone calls via SIP server or via virtual lines purchased from a SIP services
provider;
• can be configured remotely from a web interface;
• in the master version (Art. 1456), does not require door entry monitors to be connected.
1.
Ethernet port for ViP system riser input (default addressing:
“Autoip”
).
2.
Dip switches for the procedures
“Reboot with predetermined network settings”
and
“Restoring factory settings”
.
3.
Power supply input via
Art. 1441, Art. 1441B
.
4. CV1
and
CV2
for setting port
HOME2.
5. CV3
and
CV4
for setting port
HOME3.
6. HOME4
non POE
Ethernet port for PC or router connection (default:
“Static IP address”
192.168.1.200, netmask
255.255.255.0).
7. HOME3
“POE”
settable Ethernet port
non POE
(default:
“Static IP address”
192.168.1.200, netmask 255.255.255.0).
8. HOME2
“POE”
settable Ethernet port
non POE
(default:
“Static IP address”
192.168.1.200, netmask 255.255.255.0).
9. HOME1
Ethernet port
“POE”
(default:
“Static IP address”
192.168.1.200, netmask 255.255.255.0).
With port
“POE”
DO NOT use standard Ethernet to connect to the router or to the PC; use only the red
Comelit cable Art. 1449 to connect to the router or to the PC.