www.comdronic.co.uk
Strainer Removal / Replacement
Parts Required:
Step 1
–
Remove the male connectors from the top of the meter using a 13mm wrench.
Step 2
–
Remove the strainers from their housings using the 8.5mm screwdriver bit provided (or, alternatively,
an 8.0mm screwdriver).
Step 3
–
If the strainers are being reused, clean them in a soapy solution and then flush them with a
pressurised air / water source.
Step 4
–
Refit the cleaned / new strainers.
Step 5
–
Refit the male connectors so that they are firm, but not overtight
(and don’t forget the O
-rings!).
Spare set of
strainers.
8.5mm bit for strainer
removal and re-fitting.
Gently unscrew the
male connectors from
the strainer housings.
IMPORTANT - Take care
not to disturb (i.e. move)
the strainer housings. If a
male connector does
n’t
readily unscrew, use a
14mm wrench to hold the
strainer housing in place
before any additional
force is applied.
Retain O-rings for
later reassembly.
Use the 8.5mm bit in
the bit-holder to gently
unscrew the strainers
from their housings.
IMPORTANT
–
Clean any
dirt that may be present in
the thread before
attempting to remove the
strainer. Any attempt to
unscrew a strainer through
a dirty thread may cause
the strainer to become
seized in its housing.
A3
Male connector.
Strainer housing.
Содержание AC7
Страница 2: ...www comdronic co uk ...
Страница 22: ...www comdronic co uk User Notes ...