Blower pack is suitable for maximum operating ambient temperature of 40C deg/104F deg.
Tubing
All tubing
must
be sealed properly.
Seal all joints
– especially those at the teller and customer units.
All inside edges of tube joints
must be de-burred and ground to an angle
to prevent excessive wear on
carriers.
Timer Adjustment
Adjust timer (T1) for approximately 5 seconds greater than the time required for an empty carrier to be
recalled from the customer unit to the teller unit (this should be 2-3 seconds after the carrier lands at the
teller unit). See Appendix A for switch settings and other timing settings.
Customer Video Module (CVM) Power Switches
The CVM power switch is located on the front side of the Door Motor Control Module. Set Camera and
Monitor functions independently from each other with SW1 and SW2. Switching the unit to 24/7 will
leave the designated part powered on when the teller unit is turned off. Switching the unit to SW will turn
the designated part off when the teller unit is turned off.
Maintenance
Carriers
Carriers should be inspected regularly for signs of wear. Carriers landing hard at either customer or
teller unit may be a sign of worn wear bands on carrier.
Wear bands should be replaced regularly – usually every 3-6 months, depending on usage.
Installation
Содержание 523 Series
Страница 20: ...19 ComCo Systems Inc 800 533 3794 www comcosystems com 500508 Rev A 523 Series ...
Страница 23: ...ComCo Systems Inc 800 533 3794 www comcosystems com 500508 Rev A 22 523 Series Blank Page ...
Страница 24: ...23 ComCo Systems Inc 800 533 3794 www comcosystems com 500508 Rev A 523 Series CU BLOWER PACK ...
Страница 29: ...ComCo Systems Inc 800 533 3794 www comcosystems com 500508 Rev A 28 523 Series Blank Page ...