USER MANUAL FOR COMFLEX-6900
ENU STATUS : 1-0-0
Copyright - refer to title page
Page 44
RU device scanning is done. Note: Go to [Commissioning] page or [Management] page for device
scanning.
Figure45: RU Device
NOTE
: There are three statuses for PA Service:
Normal
,
Recovery
and
Shutdown
. If PA output power
or reflected power exceeds the threshold (32dBm for LRU, 39dBm for MRU), software will trigger
Recovery:
It will reset PA and then re-detect the PA output power and reflected power, if they are normal, the PA
Service Status will turn to
Normal
, if PA output power or reflected power is still over the threshold, PA
Service Status will turn to
Recovery
again.
If PA output power or reflected power is still over the threshold after six times of PA Recovery, PA
Service status will be
Shutdown
which will need to be reset manually.Reset at Management > PA
Reset.
Click on a specific band on the left side of RU Device page, the corresponding band information will show.
Select band to
check relative and
information.
Band
information
table
RU common
information table