4.0 Installation
4.1 Power
Requirements
The power amplifier requires a power source of 100 to 240 VAC, 50/60 Hz capable
of delivering 3000 Watts. Turn off the front panel ‘ON/OFF’ switch
before
connecting the AC power source.
4.2 Earthing
Earthing is achieved simultaneously with connection of the AC power cord to a
properly grounded power source.
4.3 Load
Requirements
The power amplifier requires an output load, antenna, or dummy load with a 50-
Ohm nominal impedance.
CAUTION
Make this external load connection before applying power to the
equipment.
4.4 Cable
Connections
The AC power cable connection is made at the rear of the power amplifier via
the receptacle connector. RF connections for Input and Output are made at via
the front Type-N connectors.
4.5 Statement Against Unspecified Use
This amplifier must be used as specified by the manufacturer. Use of this
equipment in any way not specified by the manufacturer may result in bodily
injury and/or damage to the equipment.
4.6 Controls, Indicators, and Connectors
When set to ‘ON’, the AC power indicator lamp will light, indicating that AC
power is present. The RF INPUT and OUTPUT connections are located on the front
of the power amplifier. Refer to the following discussion and Section 3.1 for the
location and functional description of all controls, indicators, and connectors.
IMPORTANT NOTE! - User Selectable Control
There are three control options available for operation of this system:
1) Manual control via the front panel controls.
2) Optional Remote control via the IEEE-488 bus.
3) Optional Remote control via RS-232/422.