3
NOTES:
1. Add suffix “T” to denote boiler with tankless heater.
2. I=B=R burner capacity is based on an oil heating value
of 140,000 Btu/gal. and with 13% CO2.
3. Net ratings based on 170 0 F temperature in radiators and
include 15% allowance for normal piping and pickup
load. Consult manufacturers for unusual piping and
pick-up requirements.
* All ratings subject to verification.
4. For equivelent square feet of radiation, divide I=B=R
output by 150.
5. 120 Volts, 15 Amps, & 60 Hz. required to operate this
boiler.
6. The MEA number for the series is 182-86E
7. For altitudes above 2,000 ft. ratings may be reduced at
the rate of 4% for every 1,000 ft. above sea level.
7. The MEA number for the Beckett burners used on the
are as follows: AF – 156-77-E, AFG – 213-83-E, AFII
85 – 24-92-E, AFII 150 – 456-90-E.
BOILER
SEC-
TION
A
LENGTH
OF
FLUSH
JACKET
B
FRONT OF CAST-
ING
TO CENTER LINE
OF
FLUE OUTLET
C
DIA. OF
FLUE
OUTLET
3
17 ⅞"
11 ¼"
6"
4
21 ½"
12 ⅝"
6"
5
25 ⅛"
14 ¼"
7"
6
29 ¼"
15
15
⁄
16
"
8"
7
32 ⅞"
17
15
⁄
16
"
8"
dimENSiONAL dATA
dimENSiONS
!
WARNING
All installations of boilers and venting should
be done only by a qualified expert and in ac-
cordance with the appropriate utica boilers
manual. Installing or venting a boiler or any
other gas appliance with improper methods or
materials may result in serious injury or death
due to fire or to asphyxiation from poisonous
gases such as carbon monoxide which is odor-
less and invisible.