4
Table 1- DIMENSIONS FOR NATURAL GAS
Model #
Natural
Gas Inlet
Dimensions
Pump
size
Supply &
Return
Tappings
A
B
C
D
E
-50
½"
11¼
2⅛
3
6⅜
27
1¼"
-100
½"
15⅛
4⅛
3
6⅜
27
1¼"
-125
½"
19
6
3
6⅜
27
1¼"
-150
½"
19
6
4
6⅜
27
1¼"
-200
½"
22⅞
8
4
7
28
1¼"
NOTE:
For altitudes above 2,000 ft. ratings should be reduced at the rate of 4% for
each 1,000 ft. above sea level.
BOILER RATINGS, CAPACITIES & DIMENSIONS
!
WARNING
All installations of boilers and venting should be done only by a qualified expert and in accordance with
the appropriate utica boilers manual. Installing or venting a boiler or any other gas appliance with
improper methods or materials may result in serious injury or death due to fire or to asphyxiation from
poisonous gases such as carbon monoxide which is odorless and invisible.
Figure 1 -Boiler Dimensions
Содержание CDVB-100
Страница 15: ...15 HORIZONTAL VENT INSTALLATION INSTRUCTIONS Figure 9 Figure 7a Vent Cap Figure 7b Figure 8 ...
Страница 22: ...22 HORIZONTAL VENT INSTALLATION INSTRUCTIONS Figure 16 Termination Clearances ...
Страница 31: ...31 PILOT PILOT ELECTRICAL WIRING Figure 26 HOT WATER CONTROL AND INTERMITTENT IGNITION WIRING ...
Страница 44: ...Columbia Company Main offices and factory Pottstown PA ...