32
THERMOSTAT INSTALLATION
1.
Thermostat should be installed on an inside wall about
four feet above the floor.
2.
Never install a thermostat on an outside wall.
3.
Check thermostat operation by raising and lowering
thermostat setting as required to start and stop the
burners.
4.
Instructions for the final adjustment of the thermostat
are packaged with the thermostat (adjusting heating
anticipator, calibration, etc.)
THINGS TO AVOID WHEN LOCATING THERMOSTATS
DEAD SPOTS:
Corners and alcoves
Behind doors
COLD SPOTS:
HOT SPOTS:
Concealed pipes or
ducts
Concealed pipes
Fireplace or chimney
Stairwells - drafts
TV sets
Radios
Unheated rooms on
other side of wall
Lamps
Direct sunlight
Outside walls
Kitchens
A. This appliance is equipped with an ignition device
which automatically lights the pilot. Do not try to light
the pilot by hand.
B.
BEFORE OPERATING smell all around the appliance
area for gas. Be sure to smell next to the floor
because some gas is heavier than air and will settle
on the floor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch. Do not use any
phone in your building.
• Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s
instructions. If you cannot reach your gas
supplier, call the fire department.
C. Use only your hand to move the system control
switch. Never use tools. If the switch will not move
by hand, don’t try to repair it, call a qualified service
technician. Force or attempted repair may result in a
fire or explosion.
!
WARNING
Force or attempted repair may result in a fire
or explosion.
D. Do not use this appliance if any part has been under
water. Immediately call a qualified service technician
to inspect the appliance and to replace any part of
the control system and any gas control which has
been under water.
LIGHTING INSTRUCTIONS
ELECTRICAL WIRING
!
WARNING
If you do not follow these instructions exactly,
a fire or explosion may result causing property
damage, personal injury or loss of life.
Before operating, verify boiler and system are full of
water to minimum pressure (this is usually 12 psi on most
systems) and system is vented of air. See operating and
lighting instructions.
FOR YOUR SAFETY READ BEFORE OPERATING
!
WARNING
If these instructions are not followed exactly,
a fire or explosion may result causing property
damage, personal injury or loss of life.
Содержание CDVB-100
Страница 15: ...15 HORIZONTAL VENT INSTALLATION INSTRUCTIONS Figure 9 Figure 7a Vent Cap Figure 7b Figure 8 ...
Страница 22: ...22 HORIZONTAL VENT INSTALLATION INSTRUCTIONS Figure 16 Termination Clearances ...
Страница 31: ...31 PILOT PILOT ELECTRICAL WIRING Figure 26 HOT WATER CONTROL AND INTERMITTENT IGNITION WIRING ...
Страница 44: ...Columbia Company Main offices and factory Pottstown PA ...