________________________________________________________________________
Columbia Weather Systems, Inc.
4.
To continue troubleshooting; place the black probe of the
multimeter on terminal #8 and the red probe on terminal #9.
5.
As the wind vane rotates, the voltage reading will vary from 0 to
3.3 volts DC. If the vane is pointing south, the voltage reading
should be 1.65 volts.
6.
If the voltage reading is not changing when the vane is rotating
or if the value is out of the normal range (0 to 3.3 volts DC) the
wind sensor is defective and should be returned to the factory for
repair.
Note: Please follow the procedure in Section 12: User Support
Information for returning any defective items to the factory.