36
www.colormetrics.info
Color
metrics V1506
37
can transmit, setting an appropriate inter-character delay will keep the reader from overrunning
the host input buffer. The default is 2ms.
Default Page Button
After you click the Default Button, the general settings page will change back to the default
value. Settings are not sent to MSR until the "Send to MSR" button is clicked.
Help Button
Click the help button to open the help index for this section.
Pre/Postamble
Preamble
Characters can be added to the beginning of the reader's output string of data. These can be
special characters for identifying a specific reading station, to format a message header
expected by the receiving host, or any other character string. Up to nine ASCII characters can
be defined for the Premable.
Postamble
The Postamble serves the same purpose as the Preamble, except the extra characters are
added to the end of a data string. The Postamble can be added only after a terminator
character, if specified.
Track Prefix and Suffix
For some Host applications, it may be convenient to start or end a string of reader data with a
Sentinel or terminator character.The maximum Prefix/Suffix string is six charecters and its
default is NULL(no prefix or suffix).
Track Start Sentinels
Characters can be added to the beginning of each track data string to simulate the start of the
track data. These can be special characters for identifying a specific track.
38
End Sentinel
The magnetic stripe End Sentinel character can be added to the end of a magnetic stripe data
string. This character simulates the end of character for track1, track2 or track3. This default is
'?'
Track Settings
Track Selection
There are three tracks of information possible on a magnetic stripe. This option selects the
tracks that will be decoded (read). Note that the magnetic stripe reader must have the
hardware configuration (read head and circuits) for reading the specified tracks. If a single or
dual track reader is used, the heads must be positioned to read the tracks selected by this
option. The default is Any Track.(All tracks written on the card will be read).
Track Separator Selection
This option allows the user to select the character to be used to separate data decoded by a
multiple-track reader. The default value is CR
Send Start/End Sentinel
The reader can send the Start/End sentinel for a track, decoded without error.
38
End Sentinel
The magnetic stripe End Sentinel character can be added to the end of a magnetic stripe data
string. This character simulates the end of character for track1, track2 or track3. This default is
'?'
Track Settings
Track Selection
There are three tracks of information possible on a magnetic stripe. This option selects the
tracks that will be decoded (read). Note that the magnetic stripe reader must have the
hardware configuration (read head and circuits) for reading the specified tracks. If a single or
dual track reader is used, the heads must be positioned to read the tracks selected by this
option. The default is Any Track.(All tracks written on the card will be read).
Track Separator Selection
This option allows the user to select the character to be used to separate data decoded by a
multiple-track reader. The default value is CR
Send Start/End Sentinel
The reader can send the Start/End sentinel for a track, decoded without error.
Содержание V1506
Страница 10: ...10 www colormetrics info Colormetrics V1506 11 2 6 Internal Layout ...
Страница 24: ...24 www colormetrics info Colormetrics V1506 25 3 Click Next 4 Select None Click Next 5 Click OK ...
Страница 25: ...25 www colormetrics info Colormetrics V1506 26 6 Select Support Multi Monitor System Click Next 7 Click Next ...
Страница 26: ...26 www colormetrics info Colormetrics V1506 27 8 Click Next 9 Click Next ...
Страница 48: ...48 www colormetrics info Colormetrics V1506 49 ...